NB8LE-63M residual current action circuit breaker is mainly suitable for AC 50Hz, rated voltage of 230V, rated current to 63A in commercial office buildings, civil residential and general industrial use of terminal distribution lines, to provide overload, short circuit protection and leakage protection for the line, but also under normal circumstances for the line infrequent conversion operation.
Conform to the standard: GB/T16917.1 IEC61009-1
Technical parameters
Rated current(A) | 6、10、16、20、25、32、 40、50、63 | Rated residual operating current (mA) | General type: 0.01A, 0.03A, 0.05A, 0.075A, 0.1A, 0.3A; Delay type: 0.05A, 0.075A, 0.1A, 0.3A | Type of leakage protection | Type A, Type AC | Action type | General, time-delayed | Rated Voltage (V) | 230 | Rated Frequency (Hz) | 50 | Number of poles | 1P+N、2P | Mechanical life (times) | 20000 | Electrical life (times) | 10000 | Rated short-circuit breaking capacity (A) | 10000 | Running short-circuit breaking capacity (A) | 10000 | Rated insulation voltage (V) | 500 | Rated impulse withstand voltage (1.2/50)(kV) | 4 | Dielectric test voltage (V) | (50Hz, 1 minute) 2000 | This article introduces CHINT/CHINT NB8LE-63M residual current action circuit breaker If you are interested, please also contact our customer service, we are looking forward to your call, and hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT NB1LG-40 residual current action circuit breaker
NB1LG-40 residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, rated current to 40A line, when the person is electrocuted or the power grid leakage current or voltage exceeds the specified value, the residual current action circuit breaker can be quickly cut off in a very short time.
|
|
CHINT/CHINT AX-5 auxiliary contacts
The AX-5 auxiliary contact is suitable for AC 50Hz, the agreed heating current to 6A, the rated voltage to 415V or the DC rated voltage to 130V, and it is assembled with the NL1 residual current action circuit breaker for the signal indication of the long-distance circuit breaker.
Conform to the standard: GB/T 14048.5, ...
|
|
CHINT/CHINT NBH8LE-40□ residual current action circuit breaker
NBH8LE-40 □ residual current action circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated voltage 230V, rated current to 40A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the circuit breaker can quickly cut off the fault power supply in a very short time, ...
|
|
CHINT/CHINT Terminal Appliance UVT-X1 Undervoltage Tripper
Rated Operating Voltage (Ue) : AC 230V , 50Hz;
Rated insulation voltage (Ui): 500V;
Undervoltage action setting value: (35%-70%) Ue;
Action characteristics: the external voltage ≤35%Ue, and the product should prevent the circuit breaker from closing; 35%Ue≤ external voltage ...
|
|
CHINT/CHINT NB1L-40□ residual current action circuit breaker
NB1L-40 □ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...
|
|
CHINT/CHINT CJX1 Series AC Contactor Quota insulation voltage 660V
Introduction: CHINT/CHINT AC contactor CJX1-9 is mainly used for AC 50Hz or 60Hz, the rated insulation voltage is 660V-1000V, and the rated working current is 9A-475A when the rated working voltage is 380V under the AC-3 use category, and is suitable for controlling AC electric ...
|
|
CHINT/CHINT Button & Signal Light NDT1 Series Warning Light
NDT1 series warning light, with integrated multi-layer structure, is suitable for indication, warning, fault and other indication signals in telecommunications, electrical and other lines with AC 50Hz (or 60Hz), rated working voltage of 220V and below or DC working voltage of 24V and below. Wide range of applications ...
|
|
CHINT/CHINT Terminal Appliance UVT-X3 Undervoltage Tripper
Rated working voltage (Ue): AC230V, 50Hz;
Rated insulation voltage (Ui): 500V;
Undervoltage action setting value: (35%-70%) Ue;
Mechanical durability: The mechanical durability of the tripper is 4000 operating cycles.
Tripping characteristics: external voltage≤35%Ue, ...
|
|
CHINT/CHINT CJ20 Series AC Contactor CJ20-160
CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.
|
|
CHINT/CHINT CJ40 series AC contactors
● CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching on and off circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT LAY39 series buttons
LAY39 series button is suitable for AC 50Hz or 60Hz, rated working voltage 380V and below or DC working voltage 220V in industrial control circuits, as electromagnetic starters, contactors, relays and other electrical circuit control, with indicator light button is also suitable for light signal ...
|
|
CHINT/CHINT CJ20 Series AC Contactor CJ20-10
CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.
|
|
CHINT/CHINT NC1 Series AC Contactor Withstand voltage 6kv
Introduction: CHINT/CHINT AC contactor NC1-09 (Z) (hereinafter referred to as contactor), mainly used for AC 50Hz (or 60Hz), rated working voltage to 690V, in AC-3, 400 (380) V use category rated working current to 95A in the circuit, for long-distance connection and breaking circuit ...
|
|
CHINT/CHINT NCH8G Home AC Contactor NCH8G-25/02
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NBHLE-63Y residual current action circuit breaker
NBHLE-63Y residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current to 63A line, play the role of overload, short circuit and leakage protection, can also be used as infrequent line on/off under normal circumstances.
The product conforms to IEC61009-1, GB/T 1691 ...
|
|
CHINT/CHINT AC Contactor NC3 Series RT16-32 Fuse
Introduction: CHINT/CHINT AC contactor NC3-09 (hereinafter referred to as contactor) is mainly used for AC 50Hz (or 60Hz), rated working voltage to 380V (NC3-09 - 16 can be up to 660V) rated working current to 170A power system to connect and break circuits, and with the appropriate ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/01
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NKB1 Control & Protection Switchgear
NKB1 series control and protection switchgear (CPS) (hereinafter referred to as "switch") is mainly used in AC 50Hz (60Hz), rated working voltage to 690V, rated working current 1A to 125A, controller setting current 0.4A to 125A, control motor power 0.12kW to 55kW ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-40/20
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT YBLX-WL Series Position Switch YBLX-WL/NJ/S2
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|