Introduction: NJS1 series time relay is mainly used as a time control component in the control circuit of AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V, and the circuit is turned on or off at a predetermined time.
Product parameters
Working mode: power-on delay
Number of contacts: Delay 1 changeover
Contact capacity: Ue/le : AC-15 240V/0.75A, AC415V/0.47A; DC-13 220V/0.27A; Ith : 5A
Rated control power supply voltage: AC/DC24V - 48V, AC/DC100V - 240V, AC220V, AC380V, 50Hz
Allowable fluctuation range of rated control supply voltage: 85%-110%
Electrical life: 1x10*5
Mechanical life: 1x10*8
Delay accuracy: ≤0.5% soil for 50ms
Ambient temperature: -5C - +40°C
Power consumption: ≤3VA
Installation: panel type, device type, guide rail type
Matching base: panel type: CZS08S CZS11S CZS08G device type or rail type: CZS08C CZF11A-E
This article introduces CHINT/CHINT time relay NJS1 series delay accuracy 0.5% soil 50ms products, if you are interested in CHINT/CHINT time relay, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT NR5 series thermal overload relays
NR5 series thermal overload relay is suitable for AC 50Hz (or 60Hz), rated working voltage to 690V, working current 0.1-630A long-term work or intermittent long-term work of AC motor overload and phase failure protection, but also has temperature compensation, action indication, automatic ...
|
|
CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ
Introduction: NJX2 miniature electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; A variety of device sockets are available; It has mechanical locking, power-on indication and mechanical indication functions for selection.
...
|
|
CHINT/CHINT Time Relay NTE8 Series Reset time ≤1s
Introduction: NTE8 series time relay is mainly used as a time control component in the control circuit of AC 50Hz, rated control power supply voltage to 415V and DC rated control power supply voltage to 24V, and the circuit is turned on or off at a predetermined time.
...
|
|
CHINT NJA1-KG Relay (Intelligent Time Control Switch)
NJA1-KG relay is mainly used as a timing (alarm clock), switch-on or off-control in the control circuit with AC frequency of 50Hz, rated control power supply voltage to 240V and DC rated control power supply voltage to 240V.
|
|
CHINT/CHINT Motor Control & Protection Appliance -JR36 Series Thermal Overload Relay
JR36 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current 0.25-160A long-term work or intermittent long-term work of AC motor overload and phase failure protection.
Thermal relays have phase failure protection, temperature compensation, self-...
|
|
CHINT/CHINT Solid State Relay NJG1 Series Load power factor 0.5
Introduction: NJG1 series solid state relay adopts photoelectric isolation between input and output, one-way thyristor reverse parallel output, zero-crossing conduction, built-in RC absorption loop, MOV protection, epoxy resin potting. Widely used in electric furnace heating constant temperature system, CNC machinery, plastic machinery, food machinery, ...
|
|
CHINT/CHINT Level Relay NJB1-YW Reset Resistance 250kΩ
Introduction: NJB1-YW liquid level relay is suitable for automatic water level control in industrial facilities and equipment, civil water towers, high-level water tanks, underground reservoirs and other occasions. This product is not suitable for level control of flammable and explosive liquids such as oil, chemical liquids, etc.
...
|
|
CHINT/CHINT Motor Control & Protection Appliance -JRS1 Series Thermal Overload Relay
JRS1 series thermal overload relay (hereinafter referred to as thermal relay) is mainly used for AC 50Hz/60Hz, voltage to 690V, current (0.1-80)A long-term work or intermittent long-term work AC motor overload and phase failure protection.
The thermal relay has phase failure protection, temperature compensation, dynamic ...
|
|
CHINT/CHINT Thermal Overload Relay NXR Series Auxiliary Contacts 1NO+1NC
Introduction: NXR series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, setting current 0.1-630A long-term work or intermittent work of AC motor overload and phase failure protection. Thermal relays also feature temperature compensation, action indication ...
|
|
CHINT/CHINT Relay KG316T Time Control Switch
Product Overview
KG316T series time-controlled switch is mainly used in the automatic control circuit of AC 50Hz, rated control power supply voltage to 220V, rated working current to 3A, as a regular switching on and off control of street lights, advertising light boxes and other equipment.
Technical data KG31 6T
Rated...
|
|
CHINT/CHINT electromagnetic relay JQX-13F switching current 10A
Introduction: JQX-13F small high-power electromagnetic relay 10A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT Motor Control & Protection Appliances - NRE8 Series Electronic Overload Relay
NRE8 series electronic overload relay (hereinafter referred to as the relay) is mainly used in the circuit with AC 50/60Hz, rated working voltage below 690V, and the current is within the range of the setting current calibrated by the casing, for three-phase motor overload and phase failure protection.
This relay is an application microcontroller ...
|
|
CHINT/CHINT Terminal Appliances — Terminal Box — NX30H Series Distribution Box
NX30H series open/concealed distribution box (box) (hereinafter referred to as distribution box box) is an empty housing before installing 9mm modular terminal electrical components, suitable for circuits with rated voltage of 230V/400V and rated current to 100A. The installation mode of the distribution box box has two ...
|
|
CHINT/CHINT Relay NJX-13FW Size: 27.9x21.9x35.5mm
Introduction: NJX-13FW relay 2Z, 2ZS, 3ZS, 4ZS four contact forms: no oxidation, zero arcing, long life; The transparent cover is sealed and sealed, waterproof, dustproof and anti-corrosion, and can be used in harsh environments such as low air pressure; AC/DC specifications are complete, and the installation methods are diverse; A variety of sockets are available.
|
|
CHINT/CHINT Small Electromagnetic Relay NJX3 has a rated voltage of 24VAC
Introduction: CHINT/CHINT miniature electromagnetic relay NJX3 has three contact forms: 1Z, 2Z and 3Z; Small structure, low power consumption, strong carrying capacity and high reliability; Widely used in the HVAC industry, it is used to control condensers, compressors, air conditioners and other equipment, and is the basic element in the air conditioning industry.
|
|
CHINT/CHINT Terminal Appliance —NBH8-40□ Household Circuit Breaker
NBH8-40 □ household circuit breaker is mainly used for AC 50Hz, rated voltage to 230V, rated current to 40A line as overload and short circuit protection of power lines, and can also be used for infrequent switching of electrical devices and power lines under normal circumstances.
Standard: GB/T 10963 ...
|
|
CHINT/CHINT JZ7 series intermediate relay
JZ7 series intermediate relay (hereinafter referred to as the relay) is mainly used in the control circuit of AC 50Hz (can be used for 60Hz after derivation), rated working voltage to 380V or DC rated working voltage to 220V, used to control various electromagnetic coils, so as to expand the signal or transmit the signal to the ...
|
|
CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ
Introduction: JQX-13FA small high-power electromagnetic relay 20A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT JZC4 series contactor relay
JZC4 series contactor relay is mainly used in relay control, signal transmission, isolation amplification and other circuits with AC 50Hz or 60Hz, rated working voltage to 400V and DC rated voltage to 220V, for switching, breaking and amplifying.
Standards: GB/T 14048.5, IEC 6 ...
|
|
CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper
Rated insulation voltage (Ui): 500V;
Rated operating current at different rated operating voltages (see Table 1)
Usage Category: AC-12, DC-12
Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. Tripper ...
|
|