The common faults of Banner displacement sensors are described in seven points, the details are as follows:
The linear line works on the same principle as a sliding rheostat and is used as a voltage divider, which represents the actual position of the measured position with a relative output voltage. There are the following requirements for the work of this device:
1. If the electronic ruler has been used for a long time, and the seal has been aged, and there are many impurities mixed with it, and the water mixture and oil will seriously affect the contact resistance of the brush, which will make the displayed numbers keep jumping. At this time, it can be said that the electronic ruler of the linear Banner displacement sensor has been damaged and needs to be replaced.
2. If the capacity of the power supply is very small, there will be many situations, so the power supply needs to have sufficient capacity. Then, if the capacity is insufficient, it will cause the following situation: the movement of the melt will cause the display of the clamping electronic ruler to change and fluctuate, or the movement of the clamping will cause the display of the injection electronic ruler to fluctuate, resulting in a large error in the measurement results. If the driving power supply of the solenoid valve is at the same time as the power supply of the linear Banner displacement sensor, the above situation is more likely to occur, and the voltage level of the multimeter can even be measured with the voltage level of the multimeter in serious cases. If the situation is not caused by high-frequency interference, electrostatic interference, or neutralization is not good enough, then it is possible that the power supply is too small.
3. Frequency modulation interference and electrostatic interference may make the display number of the electronic ruler of the linear banner displacement sensor jump. The signal line of the electronic ruler and the strong current line of the equipment should be separated from the wiring slot. The use of grounding brackets must be mandatory, and at the same time, the housing of the electronic ruler must be in good contact with the ground. The signal wire needs to be shielded, and a section of the electrical box should be grounded with the shielded wire.
If there is high-frequency interference, the voltage measurement using the multimeter will usually show normal, but the display number will jump non-stop; In the case of electrostatic interference, the situation is the same as that of high-frequency interference. To prove whether it is electrostatic interference, you can first use a section of power cord to connect the cover screw of the electronic ruler with some metal on the machine, as long as it is short-connected, the electrostatic interference will be eliminated immediately. However, if you want to eliminate high-frequency interference, it is difficult to use the above method, and high-frequency interference often occurs in frequency converter savers and manipulators, so you can try to use the method of stopping high-frequency power savers or manipulators to verify whether it is high-frequency interference.
4. If the electronic ruler of the linear banner displacement sensor is in the process of working, the display data at a certain point beats regularly, or when the data is not displayed, it is necessary to check whether the insulation of the connecting wire is damaged, and the short circuit to the ground caused by regular contact with the shell of the machine.
5. The voltage of the power supply must be stable, and the industrial voltage needs to meet the stability of ±0.1 [%], for example, if the reference voltage is 10V, it can allow a fluctuation of ± 0.01V, if not, it will cause the fluctuation of the displayed trap. However, if the amplitude of the fluctuation of the display at this time does not exceed the amplitude of the fluctuation of the fluctuating voltage, then the electronic ruler is normal.
6. The alignment of the linear Banner displacement sensor needs to be very good, but the parallelism can be allowed to have an error of ±0.5mm, and the angle can be allowed to have an error of ±12°. However, if the parallelism error and angle error are large, the display number will jump. In such a situation, the parallelism and angle must be adjusted.
7. In the process of connection, we must pay more attention to the fact that the three wires of the electronic ruler cannot be connected wrong, and the power line and output line cannot be replaced. If the above line is wrong, there will be a large linearity error, it is difficult to control, the accuracy of the control will become very poor, and the display is easy to jump and so on.
|
More on that
|
Banner Sensors – Cleaning Considerations for Fiber Optic Pressure Sensors
General Notes:
1. Avoid pulling, squeezing or twisting the optical fiber cable, do not pull when trying to unwrap the entangled optical fiber cable, you need to be patient and careful to untie it at this time.
2. Avoid sharp bending radius (>50mm) of optical fiber cable.
3. When the conduit is removed from the fiber optic signal demodulator ...
|
|
Banner Sensors – A way to test the quality of pressure sensors
First, the test method of pressure sensor
The test on pressure sensors mainly includes the following aspects:
Resistance test
Output signal test
Overload test
1. Resistance test
The test machines are as follows: power supply, multimeter, ammeter, ...
|
|
Banner Sensor - Installation method and precautions for pressure sensor
1. Flange fixed installation
Flange mounting is to connect the pressure sensor to the flange and fix the flange to the measured object. The advantage of this installation method is that it is simple in structure, easy to install and disassemble, and suitable for occasions where frequent sensor replacement is required.
But...
|
|
Features of Banner laser distance sensors
(1) The Ultimate Problem Solver: Solve the most challenging applications by reducing sensor inventory with reliable, durable sensors
(2) Regardless of the reflectivity of the target surface, the solution is difficult distance-based applications, including black foam on black plastic, black rubber in front of metal, multi-packing, etc.
|
|
Banner Sensors – The difference between a level sensor and a level switch, a level controller, a level transmitter, and a level gauge
Liquid level sensors
A liquid level sensor is a common sensor that measures the position of a liquid level, and it is an output that converts the height of the level into an electrical signal. The liquid level sensor is a modular circuit, which has the advantages of acid resistance, moisture resistance, shock resistance, corrosion resistance, etc., and the circuit contains constant current feedback ...
|
|
Banner Engineering VS8 series of high-performance miniature sensors won the "Innovative Product" award
On September 18, 2018, the 14th MM New Automation Forum 2018 was successfully held at the Purple Mountain Hotel in Shanghai, hosted by the mechanical media MM Modern Manufacturing magazine. The theme of this forum is to take data as a starting point and make manufacturing more excellent, emphasizing the excellent manufacturing of digital practices. By dividing ...
|
|
Banner Sensors – How to Choose a Color Sensor?
1. What is the purpose of the application?
2. What are the existing power supply types? AC or DC? What is the rated voltage?
3. What equipment should be controlled by the detection system? Conveyor or inspection system?
4. What is the output load?
5. What is the working speed of the required system? In order to...
|
|
Banner Sensors – What are the common failures of displacement sensors?
The linear line works on the same principle as a sliding rheostat and is used as a voltage divider, which represents the actual position of the measured position with a relative output voltage. There are the following requirements for the work of this device:
1. If the electronic ruler has been used for a long time ...
|
|
Banner Ultrasonic Sensors FAQs
What is an ultrasonic sensor?
Ultrasonic sensors are industrial control devices that use sound waves above 20,000Hz that exceed the range of human hearing to measure and calculate the distance from the sensor to the target object.
How do ultrasonic sensors work?
The sensor has a ...
|
|
What should I pay attention to when wiring Banner safety light curtains?
1. The brown line VCC of the transmitter is connected to the brown line VCC of the receiver, and then the power supply is +24DC.
2. The transmitter black wire GND is connected to the receiver black wire GND, and then connected to the power supply negative OV.
3. The transmitter gray line CP is connected to the receiver gray line CP.
4. Receiver Blue ...
|
|
Banner Sensors – How to use the Colour Label Sensor
1. There are 4 wires for the wiring sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. Lines are not allowed ...
|
|
"2018 China Automation Industry Annual Conference" Banner won another award
The 2018 China Automation Industry Annual Conference and the 13th China Automation Industry Century Tour (CAIAC2018) were held on April 12, 2018 at Tianma Hotel, Shaoxing, Zhejiang.
CAIAC2018 aims to remember and look forward to China ...
|
|
Banner Sensors – An introduction to the application of fiber optic sensors
1. Detection of temperature
The optical fiber temperature sensor uses a polymer temperature-sensitive material that matches the refractive index of the optical fiber to coat the outside of two optical fibers that are fused together, so that the light energy is input from one optical fiber to the reflective surface and output from the other optical fiber.
|
|
What problems do Banner laser distance sensors have that need to be solved?
(1) When the target to be measured is not perpendicular to the transducer of the sensor. This is because the target of the ultrasonic test must be within an angle of no more than 10° perpendicular to the sensor.
(2) When a small beam diameter is required. Because the diameter of the general ultrasonic beam is ...
|
|
Problem solving for Banner's QCM series of color sensors
1. Discrete photodiode with color filter
The traditional practice of sensing color is to combine three to four photodiodes on a single chip, with red, green, and blue color filters placed on the surface of the photodiode (usually two blue color filters are combined together to compensate for the ...
|
|
Banner Sensors - Introduction to the classification of infrared sensors
Common infrared sensors can be divided into thermal sensors and photonic sensors.
1. Thermal sensor
The thermal sensor is the use of incident infrared radiation to cause the temperature change of the sensor, and then make the relevant physical parameters change accordingly, by measuring the change of the relevant physical parameters to determine the ...
|
|
Banner Sensor – How to use the color sensor
Method 1:
Put the color sensor on the white object, turn on the red filter, at this time the sensor will emit the frequency, count the emitted frequency, when the count reaches 255, there is a time, this time is recorded as T1.
Turn on the green filter, at this point the sensor will ...
|
|
Banner Sensors – Analysis of common alarm codes for pressure sensors
First, the reason for the alarm code of the pressure sensor
There are generally a variety of reasons for the alarm code of a pressure sensor, among which the following conditions are the following:
1. The sensor circuit is short-circuited or broken due to damage or aging of the sensor sensing element, which causes the machine code to send an alarm signal.
...
|
|
Banner Sensors – Rope Position Sensor Maintenance Considerations
1. The working principle and common parameters of the rope displacement sensor
The function of a rope-actuated displacement sensor is to convert mechanical motion into an electrical signal that can be measured, recorded or transmitted. The rope displacement sensor consists of a stretchable stainless steel rope wound around a threaded hub with a ...
|
|
Banner Sensor - Common faults and solutions for fiber optic sensors
1. There is no display on the digital display after connecting the power supply
(1) Check whether the power cord is broken and whether the plug contact is good.
(2) Whether the power fuse of the digital display meter is blown.
(3) Whether the power supply voltage meets the requirements.
2. The digital display table does not count
(1) Passing ...
|
|