Relay module with manually operated locking - PLC-RPT- 24UC/21-21AU/MS - 2910526

Create Date: 2024-8-30 12:03:23|Source: Phoenix Contact/Phoenix

  • Brand:
    Phoenix
    Origin:
    Germany
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    PLC-RPT- 24UC/21-21AU/MS - 2910526
    Product Introduction
    PLC-INTERFACE, including relay base and pluggable multi-layer gold contact relay with manual operation and integrated status LED, Push-in connection, 2 changeover contacts, input voltage: 24 V AC/DC
Product Description
PLC-INTERFACE, including relay base and pluggable multi-layer gold contact relay with manual operation and integrated status LED, Push-in connection, 2 changeover contacts, input voltage: 24 V AC/DC
Relay module with manually operated locking - PLC-RPT- 24UC/21-21AU/MS - 2910526
size

Width 14 mm

Height 80 mm

Depth 104 mm

Environmental conditions

Ambient temperature (operating) -20 °C ... 60 °C

Ambient temperature (storage / transport) -20 °C ... 85 °C

Maximum height ≤ 2000 m

Protection class RT II (relay)

IP20 (Relay Base)

≥ IP54 (mounting position)

Coil side

Rated input voltage UN 24 V AC/DC

Typical input current at UN is 18 mA

Typical response time 3 ms ... 15 ms

Typical release time range 3 ms ... 15 ms

Coil voltage 24 V DC

Protection circuit Bridge rectifier Bridge rectifier

The operating voltage is displayed with a yellow LED

Contact side

Contact Type: 2 changeover contacts

Switch contact type Single contact

Contact material AgNi + Au

The maximum switching voltage is 30 V AC

36 V DC

Minimum switching voltage 12 V (1 mA)

Minimum switching current 1 mA (12V)

The maximum starting current is 50 mA

Limit continuous current to 50 mA

Contact surface (with destructible gold plating)

Precautions If the plating is damaged, the following values can be applied

Maximum switching voltage 250 V AC/DC

The minimum switching voltage is 12 V

Limit continuous current to 6 A

Maximum start-up current 12 A (20 ms)

The minimum switching current is 10 mA

Maximum power rating (resistive load) 192 W (24 V DC)

62 W (48 V DC)

42 W (60 V DC)

55 W (110 V DC)

66 W (220 V DC)

2000 VA (250 V AC)

Switching capacity 1 A (24 V, DC13)

1.5 A (230 V, AC15)

overview

Test voltage 4 kV AC (50 Hz, 1 minute, coil/contact)

2.5 V AC (50 Hz, 1 min, CO contact/CO contact)

Mode of operation 100% working factor

Flammability rating according to UL 94 V0 (enclosure)

Mechanical life 5x106 switching cycles

Installation Position Any

Assembly Instructions Arrangement without spacing

Connect your data

Connection Name Coil Side

Connection: Push-in connection

Stripping length 8 mm

Rigid conductor cross-section 0.14 mm² ... 2.5 mm²

Flexible conductor cross-section 0.14 mm² ... 2.5 mm²

0.2 mm² … 2.5 mm² (single sleeve)

2x 0.5 mm² … 1 mm² (TWIN sleeve)

Attachable guide cross-section AWG 26 ... 14

Connect to data2

Connection Name Contact Side

Connection: Push-in connection

Stripping length 8 mm

Rigid conductor cross-section 0.14 mm² ... 2.5 mm²

Flexible conductor cross-section 0.14 mm² ... 2.5 mm²

0.2 mm² … 2.5 mm² (single sleeve)

2x 0.5 mm² … 1 mm² (TWIN sleeve)

Attachable guide cross-section AWG 26 ... 14

Standards and Specifications

Name Standards/Regulations

Standard/Procedure EN 50178

Rated insulation voltage 250 V AC

Rated overvoltage 6 kV

Insulation Foundation isolation

Pollution class 2

Overvoltage category III

UL, United States UL 508

UL 508 Recognized

UL, United States/Canada cUL 508

cUL 508 recognized

All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original **, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, money.

The above is the Germany brand Phoenix/Phoenix relay module with manual operation locking function - PLC-RPT- 24UC/21-21AU/MS - 2910526 products, the purpose of 76 technology is to survive by quality, develop by reputation, and eternal by service, give us a chance, and give you a surprise.

More on that
Phoenix/Phoenix relay module PLC-RPT- 24UC/21HC/RW - 2900324 Phoenix/Phoenix relay module PLC-RPT- 24UC/21HC/RW - 2900324

The PLC-INTERFACE is suitable for rail applications and high continuous currents, including base terminals with plug-in connection and plug-in miniature relays, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40 °C to +70 °C, 1 PDT, input voltage 24 V DC Advantage...

Phoenix/Phoenix Single Relay - REL-MR-110DC/1ICT 1081618 Phoenix/Phoenix Single Relay - REL-MR-110DC/1ICT 1081618

Pluggable miniature power relay with tungsten front contacts for high impulse currents up to 800 A peak, 1 NO contact, input voltage: 110 V DC advantage Secure isolation between coil and contact in accordance with DIN EN 50178 Depending on the model, the maximum degree of protection can be achieved up to RT ...

Relay module with manually operated locking - PLC-RSC- 24DC/21/MS - 2909649 Relay module with manually operated locking - PLC-RSC- 24DC/21/MS - 2909649

Phoenix/Phoenix PLC-INTERFACE relay module with manually operated locking, incl. PLC-BSC.../21 base terminal, screw connection, plug-in miniature relay with power contacts and manual operation, 1 changeover contact, 24 V DC ...

Phoenix/Phoenix Single Relay REL-PR-BL-125DC/4X21 - 1157973 Phoenix/Phoenix Single Relay REL-PR-BL-125DC/4X21 - 1157973

"Hot" plugging power relay, basic, 4 PDTs, status display: LED green, input voltage: 125 V DC Test voltage coil/contact 2 kVrms (50 Hz, 1 minute, coil/contact) Test voltage CO contact/CO contact 2 kVrms (50 Hz, 1 min ...

Phoenix/Phoenix Single Relay REL-MR-BL- 24AC/21-21 - 1109546 Phoenix/Phoenix Single Relay REL-MR-BL- 24AC/21-21 - 1109546

Pluggable miniature power relay in basic design with power contacts, 2 changeover contacts, input voltage 24 V AC Product Type: Single relay Mode of operation 100% working factor Mechanical life 5x106 switching cycles Insulation characteristics Overvoltage category III Pollution level 3 ...

Phoenix/Phoenix relay module PLC-RPT- 24DC/2X21/FG - 2910537 Phoenix/Phoenix relay module PLC-RPT- 24DC/2X21/FG - 2910537

PLC-INTERFACE, incl. relay base and plug-in safety relay with positively guided contacts in accordance with DIN EN 61810-3, Push-in connection, 2 changeover contacts, forced actuation, freewheeling diode, input voltage: 24 V DC Test voltage coils/contacts ...

Relay module with manually operated locking - PLC-RPT- 24DC/21-21/MS - 2910519 Relay module with manually operated locking - PLC-RPT- 24DC/21-21/MS - 2910519

PLC-INTERFACE, including relay base and pluggable power contact relay with manual operation, integrated status LEDs and freewheeling diode, Push-in connection, 2 changeover contacts, input voltage: 24 V DC size Width 14 mm Height 80 mm Depth 104 mm ...

Phoenix/Phoenix Single relay with manually operated locking - REL-MR-230AC/21-21AU/MS - 2987998 Phoenix/Phoenix Single relay with manually operated locking - REL-MR-230AC/21-21AU/MS - 2987998

Pluggable miniature relay, multi-layer contacts with hard gold plating, 2 PDTs, test keys, mechanical switch position display, status LED, coil voltage 230VAC advantage The strap can detect manual operation Integrated status LEDs The maximum switching current is 16A DC model with freewheeling diode ...

Phoenix/Phoenix Single relay with manually operated locking function - REL-IR2/LDP- 60DC/2X21 - 2903662 Phoenix/Phoenix Single relay with manually operated locking function - REL-IR2/LDP- 60DC/2X21 - 2903662

Plug-in industrial relay with power contacts, 2 PDTs, test key, status LED, freewheeling diode, mechanical switch position display, polarity: A1+, A2-, input voltage: 60 V DC size Width 21.2 mm Height 27.5 mm Depth 35.6 mm Environmental conditions Ring...

Phoenix/Phoenix relay module PLC-RPT-120UC/21-21AU -2900342 Phoenix/Phoenix relay module PLC-RPT-120UC/21-21AU -2900342

PLC-INTERFACE, incl. PLC-BPT.../21-21 base terminal with plug-in connection with plug-in miniature multilayer gold-plated contact relay for mounting on DIN rail NS 35/7.5, 2 PDTs, input voltage 120 V AC/DC advantage Low-profile design Via V8 adapter ...

Phoenix/Phoenix relay module - PLC-RPT- 24DC/ 1AU/SEN 2900313 Phoenix/Phoenix relay module - PLC-RPT- 24DC/ 1AU/SEN 2900313

The PLC-INTERFACE is suitable for input functions, including the PLC-BPT.../SEN base terminal with plug-in connection with plug-in miniature multilayer gold-plated contact relay for mounting on DIN rail NS 35/7.5, 1 normally open contact, input voltage 24 V DC advantage No additional ...

Phoenix/Phoenix relay module PLC-RPT- 24DC/ 1IC/ACT - 2900298 Phoenix/Phoenix relay module PLC-RPT- 24DC/ 1IC/ACT - 2900298

The PLC-INTERFACE is suitable for high inrush currents and consists of PLC-BPT.../1 IC/ACT base terminal with plug-in connection with plug-in miniature relay for mounting on DIN rail NS 35/7.5 with an inrush current of up to 130 A, 1 NO contact, input voltage 24 V DC ...

Phoenix/Phoenix relay module PLC-RSC-12DC/21-21/EX - 2909517 Phoenix/Phoenix relay module PLC-RSC-12DC/21-21/EX - 2909517

PLC-INTERFACE, consisting of DIN rail mounting, 14 mm base terminal with screw connection and plug-in relay with power contact, 2 changeover contacts, 12 V DC input voltage. It is certified according to the requirements of ATEX/IECEx (Zone 2) and Ex Area Class I, Zone 2. Rated...

Phoenix/Phoenix Single relay with manually operated locking - REL-OR3/LDP-48DC/3X21 - 2908897 Phoenix/Phoenix Single relay with manually operated locking - REL-OR3/LDP-48DC/3X21 - 2908897

Plug-in octal relay with power contacts, 3 PDTs, test button, freewheeling diode, mechanical switch position display, polarity: A1+, A2-, input voltage: 48 V DC size Width 35 mm Height 35 mm Depth 54.4 mm Environmental conditions Ambient temperature ( ...

Phoenix/Phoenix relay module PLC-RSC-230UC/21-21/EX - 2909512 Phoenix/Phoenix relay module PLC-RSC-230UC/21-21/EX - 2909512

PLC-INTERFACE, consisting of DIN rail mounting, 14 mm base terminal with screw connection and plug-in relay with power contacts, 2 changeover contacts, 230 V AC/220 V DC input voltage. Certified according to ATEX/IECEx (Zone 2) and Ex Area Class I, Zone 2

Phoenix/Phoenix Time Relays Timing Relay - MACX-TR-1T-POFF - 1119403 Phoenix/Phoenix Time Relays Timing Relay - MACX-TR-1T-POFF - 1119403

Phoenix Timing Relay - MACX-TR-1T-POFF - 1119403 Power-off Delay Time Relay, 24 V AC/DC ... 240 V AC/DC ample power supply with a configurable time range of 10 ms ... 10 min), two configurations, password protection, 2 P...

Relay module with manually operated locking - PLC-RSC- 24DC/21-21AU/MS - 2910507 Relay module with manually operated locking - PLC-RSC- 24DC/21-21AU/MS - 2910507

PLC-INTERFACE, including relay base and pluggable multi-layer gold contact relay with manual operation, integrated status LEDs and freewheeling diode, screw connection, 2 changeover contacts, input voltage: 24 V DC size Width 14 mm Height 80 mm Depth 104 mm ...

REL-PR3-110DC/3X21 single relay from Phoenix/Phoenix - 2908893 REL-PR3-110DC/3X21 single relay from Phoenix/Phoenix - 2908893

Plug-in high-power relay with power contacts, 3 N/O contacts, coil voltage: 110 V DC Coil side Rated input voltage UN 110 V DC Input voltage range 93.5 V DC ... 121 V DC (20 °C) Typical input current at UN is 12 mA UN's input function ...

Phoenix/Phoenix relay module PLC-RPT- 24DC/21-21/EX 2909514 Phoenix/Phoenix relay module PLC-RPT- 24DC/21-21/EX 2909514

PLC-INTERFACE, consisting of DIN rail mounting, 14 mm base terminal with plug-in connection and plug-in relay with power contact, 2 changeover contacts, 24 V DC input voltage. It is certified according to the requirements of ATEX/IECEx (Zone 2) and Ex Area Class I, Zone 2. Forehead...

Relay module with manually operated locking - PLC-RPT-230UC/21AU/MS - 2909676 Relay module with manually operated locking - PLC-RPT-230UC/21AU/MS - 2909676

PLC-INTERFACE, incl. PLC-BPT.../21 base terminal, plug-in connection, with plug-in miniature relay with multi-layer gold-plated contacts and manual operation, 1 changeover contact, 230 V AC/220 V DC input voltage size Width 6.2 mm Height 80 mm ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top