FujiElectric ZPG Single Beam Infrared Gas Analyzer

Create Date: 2024-8-30 12:03:23|Source: Fuji Electric/Fujielectric

  • Brand:
    FujiElectric
    Origin:
    Japan
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    ZPG type
    Product Introduction
    This product is a single-beam infrared gas analyzer that continuously measures the concentration of impurities CO and CO2 in atmospheric environment monitoring or air separation equipment. The sampling switching method enables continuous measurement of low gas concentrations.
Product Description
FujiElectric ZPG Single Beam Infrared Gas Analyzer

FujiElectric ZPG type


      peculiarity

      High stability: zero drift±0.5%FS/week.

      Installed in a 19-inch cabinet, it weighs about 9kg, making it compact and lightweight.

      Enables continuous measurement of low gas concentrations.

      Built-in magnetic oxygen analyzer or amperometric oxygen analyzer (optional).

      Built-in air pressure disturbance compensation, RS-485 communication, automatic correction, alarm output, O2 conversion and other functions (optional).

      The measuring parts are simple in structure and easy to maintain.

      Main specifications:
Measuring principle
NO, SO2, CO, CO2, CH4: Non-dispersive infrared absorption method (single beam)
O2: Electrochemical (built-in) or magnetic (built-in) or zirconia (external ZFK7)
Measurement composition and measuring range
NO:0~10ppm···100ppm
SO2:0~10ppm···100ppm
CO2:0~5ppm···50ppm
CO:0~5ppm···50ppm
O2 (built-in electrochemical formula): 0~10vol%··· 25vol%
O2 (built-in magnetic type): 0~5vol%··· 100vol%
O2 (external zirconia type): 0~5vol%··· 25vol%
Measuring range
1 component up to 2 ranges
repeatability
± 0.5% FS or less
Linear
± within 1% FS
Zero drift
± 0.5% FS/week
Full-scale drift
±2% FS/week
Response time (within 90%)
Within 30 seconds (Consumption time varies depending on the gas switching time)
Analog output signal
DC4~20mA or DC0~1V
Measured values are displayed
LCD with backlight (Japanese, English or Chinese: as specified)
Instantaneous values of each component, O2 to instantaneous values, O2 to average values, O2 to average values
Spanning switching
Manual and automatic range switching is possible by pressing a button, and remote switching is possible with external contact input (optional).
External contact input (optional)
Voltage input contact (supply voltage DC12~24V, maximum current 15mA)
Remote range switching, auto-correction remote start, remote output hold, average value reset
Contact output (optional)
1c relay contact (contact capacity DC24V/1A resistive load)
Instrument abnormality, correction abnormality, range identification, automatic calibration, automatic correction is driven by solenoid valve,
Upper and lower limit alarms, CO concentration peak alarms
Barometric Disturbance Compensation (Optional)
Built-in as specified
Standard features
Output signal holds, manual/automatic range switching
Optional features
Auto-Calibration, Auto-Calibration Remote Start, Remote Output Hold, Range Identification Contact Output,
Upper and lower limit alarm output, O2 conversion value output, O2 conversion average value output, average value reset contact output,
CO concentration peak alarm contact output
Communication function (optional)
RS-485 (Modbus) (9-pin D-sub output) Half-duplex serial, synchronous start and stop
Gas flow monitor under test
Yes
Size of gas inlet and outlet
Rc1/4 or NPT1/4 female
Purge gas flow
1L/min (as required)
Reference gas
Required (Dry N2 or Dry Air)
Ambient temperature and humidity
-20~60°C 90% or less (no condensation)
Supply voltage
AC100V~240V 50/60Hz
Rated power
Approx. 100VA
Dimensions
133(H)×483(W)×382(D)mm
weight
Approx. 10kg
Applicable certifications
CE marked
The condition of the gas being measured
flow rate
1.0L / min ±0.2L / min
temperature
0 ~ 50℃
pressure
10kPa or less
dust
Particles below 0.3 μm: 100 μg/Nm3 or less
Aerosol
not
moisture content
Saturation cannot exceed 2°C (the same as the measured gas and the reference gas)
Corrosive components
HCL 1ppm or less

       The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow!

       In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!



More on that
FujiElectric V9071iW Human Machine Interface (HMI) FujiElectric V9071iW Human Machine Interface (HMI)

Introduction: FujiElectric V9071iW Human Machine Interface (HMI) 7-inch, TFT, 16.7M Color, WVGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F Product Picture Show: Specifications: The above introduction ...

FujiElectric V9080iC Human Machine Interface (HMI) FujiElectric V9080iC Human Machine Interface (HMI)

Introduction: FujiElectric V9080iC HMI 8.4 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch Product Picture Show: Specifications: Above...

FujiElectric ZAFE Pressure-Resistant Explosion-proof Thermal Gas Analyzer FujiElectric ZAFE Pressure-Resistant Explosion-proof Thermal Gas Analyzer

FujiElectric ZAFE Pressure-Resistant Explosion-proof Thermal Gas Analyzer peculiarity NEPSI certified qualified product (Exd II.C T6Gb). Large, easy-to-see LCD display. Can communicate with a computer. Small panels ...

FujiElectric PHN Paperless Recorder FujiElectric PHN Paperless Recorder

Introduction: FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver Compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording Product Picture Show: Give birth...

FujiElectric PHA inkjet recorder FujiElectric PHA inkjet recorder

Introduction: FujiElectric PHA inkjet recorder is a 180mm paper width recorder with 6 colors of inkjet, vivid recording, and inkjet method. Thermocouples, temperature resistors, and voltage/current signals are used as inputs Product Picture Show: Key Specifications: ...

FujiElectric ZSVF compact gas analyzer FujiElectric ZSVF compact gas analyzer

FujiElectric ZSVF compact gas analyzer peculiarity It is suitable for measuring the concentration of NOx, SO2, CO, CO2, CH4, O2 gas in exhaust, gas, plant photosynthesis, biogas, etc It is possible to measure simultaneously for 5 consecutive days ...

FujiElectric TS1100/TS1101 series HMI FujiElectric TS1100/TS1101 series HMI

Introduction: FujiElectric TS1100/TS1101 series Human Machine Interface (HMI) Display Size 10.2 inch widescreen Display resolution 800×480 dots Display device TFT color Power consumption 16w Product Picture Show: Specifications: ...

FujiElectric PHE inkjet recorder FujiElectric PHE inkjet recorder

Introduction: FujiElectric PHE inkjet recorder with 6-color vivid recording / inexpensive type, abundant measurement objects, compact size, ideal for assembly into machinery and equipment, high-quality recording Product Picture Show: Product Features and Advantages: ...

FujiElectric ZAF Thermal Conductivity Gas Analyzer FujiElectric ZAF Thermal Conductivity Gas Analyzer

FujiElectric ZAF Thermal Conductivity Gas Analyzer peculiarity Large, easy-to-see LCD display. Can communicate with a computer. Compact panel mounting structure. Automatic correction function for zero point and full-scale point (optional)

FujiElectric ZKG Magnetic Oxygen Analyzer FujiElectric ZKG Magnetic Oxygen Analyzer

FujiElectric ZKG Magnetic Oxygen Analyzer peculiarity Magnetic method (pressure detection type) eliminates the need for auxiliary gases. The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases. Almost unaffected by other ...

FujiElectric ZKM zirconia gas analyzer FujiElectric ZKM zirconia gas analyzer

Introduction: FujiElectric ZKM zirconia gas analyzer peculiarity Zirconia sensors can be replaced and maintenance is simple. 4~7 seconds of rapid ringing ...

FujiElectric FLR compact ultrasonic flowmeter FujiElectric FLR compact ultrasonic flowmeter

FujiElectric FLR compact ultrasonic flowmeter peculiarity Standard accuracy of 1.5% of rate (optional 1% of rate) Fast response in just 0.2 seconds It is not necessary to open the inverter housing, and it can be accessed from ...

FujiElectric PHC type 6 color inkjet recorder FujiElectric PHC type 6 color inkjet recorder

Introduction: FujiElectric PHC type 6 color inkjet recorder, inkjet method 100mm paper width recorder, clear recording, thermocouple, temperature measurement resistance, voltage/current signal as input Product Picture Show: Main features of the product: ...

FujiElectric ZKJ Infrared Gas Analyzer FujiElectric ZKJ Infrared Gas Analyzer

FujiElectric ZKJ Infrared Gas Analyzer peculiarity It is suitable for measuring the concentration of NOx, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces Up to 5 components of the gas concentration can be continuously ...

FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI) FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI)

Introduction: FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI) supports remote operation through VNC server function, and supports various specifications as standard, and the FROM capacity has been greatly expanded by 2.2 times. Product Picture Show: Specifications: ...

FujiElectric V9150iX Human Machine Interface (HMI) FujiElectric V9150iX Human Machine Interface (HMI)

Introduction: FujiElectric V9150iX Human Machine Interface (HMI) 15-inch, TFT, 16.7M Color, XGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio Product Picture Show: Specifications: ...

FujiElectric V9100iS Human Machine Interface (HMI) FujiElectric V9100iS Human Machine Interface (HMI)

Introduction: FujiElectric V9100iS Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio Product Picture Show: Specifications: ...

FujiElectric ZSS in-line laser gas analyzer FujiElectric ZSS in-line laser gas analyzer

FujiElectric ZSS in-line laser gas analyzer peculiarity Analyzer for HCL, NH3, O2, CO, CO2, CH4 gas concentration measurement. Due to the fast response speed (less than 1~5 seconds), it can be assembled into the control system.

FujiElectric FSC Portable Ultrasonic Flow Meter FujiElectric FSC Portable Ultrasonic Flow Meter

FujiElectric FSC Portable Ultrasonic Flow Meter peculiarity An SD memory card can be used to store data for long-term measurements With calorie consumption function Rely on battery power for 12 hours of continuous work With printer (optional ...

FujiElectric UG20 Series POD FujiElectric UG20 Series POD

Introduction: FujiElectric UG20 series POD Product Introduction ●I adopt medium-to-large 7.7 inches of 128-color STN color LCD 7.7 type VGA (640 480 dots) 128 colors STN display color liquid ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top