    Product Introduction
    FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording
Product Description
Introduction: FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver Compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording

       Product Picture Show:

FujiElectric PHN Paperless Recorder

       Specifications:
General specifications
Installation method:
Panel recessed or portable
Material
Molded resins (housings, display frames)
Dimensions, weight
〈Panel Mounting〉160×144×185mm, Approx. 1.5kg (9-point input)
Supply voltage
AC100V~AC240V 50/60Hz
power consumption
Approx. 42VA (at AC240V)
External terminal section
M3 screw terminals
Operating ambient temperature
0~50°C (Model 12th = Y or R)
0~40°C (Model No. 12 = E or W)
Input part
Enter the number of points
3, 6, 9 or 12
Measurement cycle
100ms/3 points, 6 points, 9 points, 12 points
Record the period
1 second ~ 12 hours
Write cycle
1 minute ~ 12 hours
Enter the signal
12 thermocouples (B, R, S, K, E, J, T, N, W, L, U, pN)
2 types of temperature resistors (pt100, JPT100)
DC voltage〔50mV、500mV、5V (0~5V, 1~5V)〕
DC current (connect a separately sold shunt resistor to the input terminal)
Switch the type of input
Switching via front button operation (set to the same type every 2 channels)
Over-range function
It is equipped with thermocouple and temperature measuring resistor input as standard
Computing functions
First-order delay filtering, scaling, difference between channels, F-value operation, accumulation operation, open-squared operation
Display Department
display
5.7 inch STN color LCD (320×240 dots)
(Please note that there may be some pixels that are always bright or not always bright in the liquid crystal display, and due to the characteristics of the liquid crystal, there may be uneven brightness and when the ambient temperature exceeds 30°C, the overall whiteness may occur, which is not a fault.) )
Backlight life
50,000 hours
Display content
Trend chart display (up and down or left and right)
Refresh cycle 1 second ~ 12 hours optional, scale display/no display optional;
Bar graph or analogue meter display (refresh cycle of 1 second);
digital display (refresh cycle is 1 second);
Event summary display (alarm and information summary display);
Historical trend display (readable log file);
Cumulative data display;
Group settings (up to 4 groups);
Recording function
External recording media
Micro memory card (for reading and writing on the recorder, please format it via FAT16 or FAT)
Record capacity
Up to 512MB
Recording method
Set the REC key on the front to ON and record the new file name at the start of each write and the start of the record at a fixed period
Data retention period
This parameter is linked to the refresh cycle displayed in the trend chart
data format
ASCII. code (directly readable by Excel, etc.) Approx. 166 bytes per sample on average (max/min recorded with 9-channel input)
Binary number (not directly readable in Excel, etc.): about 40 bytes per sample on average (maximum/minimum value recorded for 9-channel input)
Trend data
Select one of the minimum and maximum values, instantaneous values, and average values from the data sampled during the measurement period and save them
Event data
Save alarm data as well as information data
Cumulative value data
Saves the cumulative value data for the specified time
Save the capacity
When the display refresh cycle is 30 seconds, about 1.5 years (ASCII.), about 6 years (binary number)
(9 channels recorded, minimum and maximum values recorded, when using a 256MB micro memory card)
Memory usage display
On the display screen, a bar graph shows that if the memory usage exceeds the capacity, the recording is stopped
Alarm function
Set the number of points
Up to 4 points can be set for each channel
The type of alarm
Upper and lower limits
display
When an alarm occurs, the digital display displays the status of the alarm
The history is displayed in the alarm summary
Battery Alarm: Displayed when the battery is depleted
Memory Full Alarm: Displayed when the memory is full
Relay output (optional)
Relay 10 points or open collector 18 points
or relay 10 points + open collector 18 points
Standard performance
Indicates accuracy
± of input range (0.15% + 1digit)
But the next range is ± (0.3%+1digit)
B thermocouple is 400~600°C, R and S thermocouple is 0~300°C
K, E, J, T, L, U thermocouples are -200~-100°C
Indicates the resolution
0.1℃
Standard contact compensation error
± 0.5°C (when measuring above 0°C.) However, the R, S, B, W thermocouples are ±1.0°C)
Input resistance
Approx. 1 MΩ (Approx. 100 KΩ when power supply is off)
other
clock
With Gregorian calendar function
Storage backups
The set parameters are stored in the internal non-volatile memory
The clock has a built-in lithium battery
Trend data is not backed up and is stored on a micro flash memory card
Optional features
(1) Alarm output/DI (18-channel type not available)

Additional 10-point relay output and 5-point DI input

Alarm output: 1A contact
Alarm setting method: It can be set to output each channel separately or together
DI Input: No voltage contact input
Recording start/stop and information setting, F-number arithmetic reset, cumulative arithmetic start/stop, cumulative value reset, and LCD lighting are possible
(2) Alarm output/DI/communication

Additional 18-point open collector output + 5-point DI input + RS485 communication

Alarm output: open collector output
18-point alarm setting method: can be set to each channel for separate or common output
DI Input: No Voltage Contact Input (5 points)
Recording start/stop and information setting, F-number operation reset, accumulation operation start/stop can be performed,
The cumulative value is reset and the LCD is lit
Communication specifications: Signal transmission of measured values (instantaneous values) and signal reception of parameters are possible
Communication protocol: MODBUS (RTU)
Communication mode: semi-duplex serial
Synchronization mode: start and end synchronization
Symbol Format: Binary
Data length: 8 bits
Parity: even, odd, none
Stop bit: 1 bit
Communication speed: 9600bps, 19200bps
Number of connections: up to 31
Communication distance: up to 500m in total length
Note: When connecting via RS-232C, an RS-232Có RS-485 converter is required.
Recommended product model: K3SC-10/omron
Computer support software (attached to CD-ROM standard)
O/S
Windows2000/Xp
Required memory capacity
64MB or more
content

The following two types are standard accessories

(1) Data browsing software
This is a software that can transfer past trend records from the data of a micro memory card to a computer for display, and has the function of displaying historical trends and event summaries.
(2) Parameter loading software
This is software that sets and changes various parameters of the main body on a computer.

The above is the product FujiElectric / Fuji Electric PHN type paperless recorder, mainly to understand the characteristics and product specifications of the product, we always uphold the integrity of life, sincere service attitude. If you are interested in our products, please contact our sales staff, we look forward to your call, hope our technology and service to bring you a good experience.

Our aim: to survive by quality, to develop by reputation, to serve eternity, to give us a chance, but also to give you a surprise.

More on that
FujiElectric V9100iC Human Machine Interface (HMI) FujiElectric V9100iC Human Machine Interface (HMI)

Introduction: FujiElectric V9100iC Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch Product Picture Show: Specifications: ...

FujiElectric ZAF Thermal Conductivity Gas Analyzer FujiElectric ZAF Thermal Conductivity Gas Analyzer

FujiElectric ZAF Thermal Conductivity Gas Analyzer peculiarity Large, easy-to-see LCD display. Can communicate with a computer. Compact panel mounting structure. Automatic correction function for zero point and full-scale point (optional)

FujiElectric FLR compact ultrasonic flowmeter FujiElectric FLR compact ultrasonic flowmeter

FujiElectric FLR compact ultrasonic flowmeter peculiarity Standard accuracy of 1.5% of rate (optional 1% of rate) Fast response in just 0.2 seconds It is not necessary to open the inverter housing, and it can be accessed from ...

FujiElectric FSH hybrid ultrasonic flowmeter FujiElectric FSH hybrid ultrasonic flowmeter

FujiElectric FSH hybrid ultrasonic flowmeter peculiarity The automatic switching between the pulse Doppler method using ultrasonic reflection characteristics and the propagation time difference method using ultrasonic penetration characteristics can be applied to a wide range of ...

FujiElectric FSV Ultrasonic Flowmeter FujiElectric FSV Ultrasonic Flowmeter

FujiElectric FSV Ultrasonic Flowmeter peculiarity High-precision measurement of 1.0% of rate High-speed measurement in 0.2 seconds It is a compact inverter with a front size of 142×170 mm Adopt an anti-bubble measurement method with excellent anti-bubble ability There is no need to open the cover of the converter ...

FujiElectric V9080iC Human Machine Interface (HMI) FujiElectric V9080iC Human Machine Interface (HMI)

Introduction: FujiElectric V9080iC HMI 8.4 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch Product Picture Show: Specifications: Above...

FujiElectric ZFK8 zirconia gas analyzer FujiElectric ZFK8 zirconia gas analyzer

Introduction: FujiElectric ZFK8 zirconia gas analyzer peculiarity Zirconia sensors can be replaced and maintenance is simple. Fast response speed of 4~7 seconds, which can be used for burning ...

FujiElectric PHC type 6 color inkjet recorder FujiElectric PHC type 6 color inkjet recorder

Introduction: FujiElectric PHC type 6 color inkjet recorder, inkjet method 100mm paper width recorder, clear recording, thermocouple, temperature measurement resistance, voltage/current signal as input Product Picture Show: Main features of the product: ...

FujiElectric V9150iX Human Machine Interface (HMI) FujiElectric V9150iX Human Machine Interface (HMI)

Introduction: FujiElectric V9150iX Human Machine Interface (HMI) 15-inch, TFT, 16.7M Color, XGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio Product Picture Show: Specifications: ...

FujiElectric ZRJ Infrared Gas Analyzer FujiElectric ZRJ Infrared Gas Analyzer

FujiElectric ZRJ Infrared Gas Analyzer peculiarity It is suitable for measuring the concentration of NO, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces Up to 4 components of the gas concentration ...

FujiElectric TS1070/TS1071 series HMI FujiElectric TS1070/TS1071 series HMI

Introduction: FujiElectric TS1070/TS1071 series Human Machine Interface (HMI) Display Size 7 inch widescreen Display resolution 800×480 dots Display device TFT color Display color 65.536 colors Brightness 450 cd Product Picture Show: ...

FujiElectric FSC Portable Ultrasonic Flow Meter FujiElectric FSC Portable Ultrasonic Flow Meter

FujiElectric FSC Portable Ultrasonic Flow Meter peculiarity An SD memory card can be used to store data for long-term measurements With calorie consumption function Rely on battery power for 12 hours of continuous work With printer (optional ...

FujiElectric ZSVS small gas analyzer FujiElectric ZSVS small gas analyzer

FujiElectric ZSVS small gas analyzer peculiarity It is suitable for measuring CO, CO2, CH4 and O2 gas concentrations in heat treatment furnaces and plant cultivation and chemical analysis ·. It is possible to measure the gas concentration of up to 4 components simultaneously and continuously.

FujiElectric ZPG Single Beam Infrared Gas Analyzer FujiElectric ZPG Single Beam Infrared Gas Analyzer

FujiElectric ZPG Single Beam Infrared Gas Analyzer peculiarity High stability: zero drift±0.5%FS/week. Installed in a 19-inch cabinet, it weighs about 9kg, making it compact and lightweight. Enables continuous measurement of low gas concentrations. ...

FujiElectric ZFP infrared CO2 controller FujiElectric ZFP infrared CO2 controller

FujiElectric ZFP infrared CO2 controller Main specifications: This article introduces FujiElectric ZFP infrared CO2 controller products, if you are interested in FujiElectric controller, please also contact our staff ...

FujiElectric ZKG Magnetic Oxygen Analyzer FujiElectric ZKG Magnetic Oxygen Analyzer

FujiElectric ZKG Magnetic Oxygen Analyzer peculiarity Magnetic method (pressure detection type) eliminates the need for auxiliary gases. The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases. Almost unaffected by other ...

FujiElectric UG30 Series POD FujiElectric UG30 Series POD

Introduction: FujiElectric UG30 series POD Product Introduction ■Features ●Compatible with 32,768 color displays It can handle 32,768 color displays, and the display effect is the same as that of photos. ●AV functions are substantial Video input ...

FujiElectric ZKM zirconia gas analyzer FujiElectric ZKM zirconia gas analyzer

Introduction: FujiElectric ZKM zirconia gas analyzer peculiarity Zirconia sensors can be replaced and maintenance is simple. 4~7 seconds of rapid ringing ...

FujiElectric FWD Air Ultrasonic Flow Meter FujiElectric FWD Air Ultrasonic Flow Meter

FujiElectric FWD Air Ultrasonic Flow Meter peculiarity Suitable for a variety of pipe diameters to meet your needs. Suitable for diameter 25mm~200mm. There is no pressure loss, and zero energy loss is realized. This product adopts ultra...

FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer

Introduction: FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer peculiarity Zirconia sensors can be replaced and maintenance is simple. Fast response speed of 4~7 seconds, which can be used for combustion control. It is possible to open the case without opening the shell.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top