Introduction: FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver Compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording
Product Picture Show:
Specifications:
| | Panel recessed or portable | | Molded resins (housings, display frames) | | 〈Panel Mounting〉160×144×185mm, Approx. 1.5kg (9-point input) | | | | | External terminal section | | Operating ambient temperature | 0~50°C (Model 12th = Y or R)
0~40°C (Model No. 12 = E or W) | | Enter the number of points | | | 100ms/3 points, 6 points, 9 points, 12 points | | | | | | 12 thermocouples (B, R, S, K, E, J, T, N, W, L, U, pN)
2 types of temperature resistors (pt100, JPT100)
DC voltage〔50mV、500mV、5V (0~5V, 1~5V)〕
DC current (connect a separately sold shunt resistor to the input terminal) | | Switching via front button operation (set to the same type every 2 channels) | | It is equipped with thermocouple and temperature measuring resistor input as standard | | First-order delay filtering, scaling, difference between channels, F-value operation, accumulation operation, open-squared operation | | | 5.7 inch STN color LCD (320×240 dots)
(Please note that there may be some pixels that are always bright or not always bright in the liquid crystal display, and due to the characteristics of the liquid crystal, there may be uneven brightness and when the ambient temperature exceeds 30°C, the overall whiteness may occur, which is not a fault.) ) | | | | Trend chart display (up and down or left and right)
Refresh cycle 1 second ~ 12 hours optional, scale display/no display optional;
Bar graph or analogue meter display (refresh cycle of 1 second);
digital display (refresh cycle is 1 second);
Event summary display (alarm and information summary display);
Historical trend display (readable log file);
Cumulative data display;
Group settings (up to 4 groups); | | | Micro memory card (for reading and writing on the recorder, please format it via FAT16 or FAT) | | | | Set the REC key on the front to ON and record the new file name at the start of each write and the start of the record at a fixed period | | This parameter is linked to the refresh cycle displayed in the trend chart | | ASCII. code (directly readable by Excel, etc.) Approx. 166 bytes per sample on average (max/min recorded with 9-channel input)
Binary number (not directly readable in Excel, etc.): about 40 bytes per sample on average (maximum/minimum value recorded for 9-channel input) | | Select one of the minimum and maximum values, instantaneous values, and average values from the data sampled during the measurement period and save them | | Save alarm data as well as information data | | Saves the cumulative value data for the specified time | | When the display refresh cycle is 30 seconds, about 1.5 years (ASCII.), about 6 years (binary number)
(9 channels recorded, minimum and maximum values recorded, when using a 256MB micro memory card) | | On the display screen, a bar graph shows that if the memory usage exceeds the capacity, the recording is stopped | | | Up to 4 points can be set for each channel | | | | When an alarm occurs, the digital display displays the status of the alarm
The history is displayed in the alarm summary
Battery Alarm: Displayed when the battery is depleted
Memory Full Alarm: Displayed when the memory is full | | Relay 10 points or open collector 18 points
or relay 10 points + open collector 18 points | | | ± of input range (0.15% + 1digit)
But the next range is ± (0.3%+1digit)
B thermocouple is 400~600°C, R and S thermocouple is 0~300°C
K, E, J, T, L, U thermocouples are -200~-100°C | | | Standard contact compensation error | ± 0.5°C (when measuring above 0°C.) However, the R, S, B, W thermocouples are ±1.0°C) | | Approx. 1 MΩ (Approx. 100 KΩ when power supply is off) | | | With Gregorian calendar function | | The set parameters are stored in the internal non-volatile memory
The clock has a built-in lithium battery
Trend data is not backed up and is stored on a micro flash memory card | | (1) Alarm output/DI (18-channel type not available) |
Additional 10-point relay output and 5-point DI input
Alarm output: 1A contact
Alarm setting method: It can be set to output each channel separately or together
DI Input: No voltage contact input
Recording start/stop and information setting, F-number arithmetic reset, cumulative arithmetic start/stop, cumulative value reset, and LCD lighting are possible
| (2) Alarm output/DI/communication |
Additional 18-point open collector output + 5-point DI input + RS485 communication
Alarm output: open collector output
18-point alarm setting method: can be set to each channel for separate or common output
DI Input: No Voltage Contact Input (5 points)
Recording start/stop and information setting, F-number operation reset, accumulation operation start/stop can be performed,
The cumulative value is reset and the LCD is lit
Communication specifications: Signal transmission of measured values (instantaneous values) and signal reception of parameters are possible
Communication protocol: MODBUS (RTU)
Communication mode: semi-duplex serial
Synchronization mode: start and end synchronization
Symbol Format: Binary
Data length: 8 bits
Parity: even, odd, none
Stop bit: 1 bit
Communication speed: 9600bps, 19200bps
Number of connections: up to 31
Communication distance: up to 500m in total length
Note: When connecting via RS-232C, an RS-232Có RS-485 converter is required.
Recommended product model: K3SC-10/omron
| Computer support software (attached to CD-ROM standard) | | | | | |
The following two types are standard accessories
(1) Data browsing software
This is a software that can transfer past trend records from the data of a micro memory card to a computer for display, and has the function of displaying historical trends and event summaries.
(2) Parameter loading software
This is software that sets and changes various parameters of the main body on a computer.
|
The above is the product FujiElectric / Fuji Electric PHN type paperless recorder, mainly to understand the characteristics and product specifications of the product, we always uphold the integrity of life, sincere service attitude. If you are interested in our products, please contact our sales staff, we look forward to your call, hope our technology and service to bring you a good experience.
Our aim: to survive by quality, to develop by reputation, to serve eternity, to give us a chance, but also to give you a surprise.
|
More on that
|
FujiElectric V9100iC Human Machine Interface (HMI)
Introduction: FujiElectric V9100iC Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZAF Thermal Conductivity Gas Analyzer
FujiElectric ZAF Thermal Conductivity Gas Analyzer
peculiarity
Large, easy-to-see LCD display.
Can communicate with a computer.
Compact panel mounting structure.
Automatic correction function for zero point and full-scale point (optional)
|
|
FujiElectric FLR compact ultrasonic flowmeter
FujiElectric FLR compact ultrasonic flowmeter
peculiarity
Standard accuracy of 1.5% of rate (optional 1% of rate)
Fast response in just 0.2 seconds
It is not necessary to open the inverter housing, and it can be accessed from ...
|
|
FujiElectric FSH hybrid ultrasonic flowmeter
FujiElectric FSH hybrid ultrasonic flowmeter
peculiarity
The automatic switching between the pulse Doppler method using ultrasonic reflection characteristics and the propagation time difference method using ultrasonic penetration characteristics can be applied to a wide range of ...
|
|
FujiElectric FSV Ultrasonic Flowmeter
FujiElectric FSV Ultrasonic Flowmeter
peculiarity
High-precision measurement of 1.0% of rate
High-speed measurement in 0.2 seconds
It is a compact inverter with a front size of 142×170 mm
Adopt an anti-bubble measurement method with excellent anti-bubble ability
There is no need to open the cover of the converter ...
|
|
FujiElectric V9080iC Human Machine Interface (HMI)
Introduction: FujiElectric V9080iC HMI 8.4 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
Above...
|
|
FujiElectric ZFK8 zirconia gas analyzer
Introduction: FujiElectric ZFK8 zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for burning ...
|
|
FujiElectric PHC type 6 color inkjet recorder
Introduction: FujiElectric PHC type 6 color inkjet recorder, inkjet method 100mm paper width recorder, clear recording, thermocouple, temperature measurement resistance, voltage/current signal as input
Product Picture Show:
Main features of the product:
...
|
|
FujiElectric V9150iX Human Machine Interface (HMI)
Introduction: FujiElectric V9150iX Human Machine Interface (HMI) 15-inch, TFT, 16.7M Color, XGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZRJ Infrared Gas Analyzer
FujiElectric ZRJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NO, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Up to 4 components of the gas concentration ...
|
|
FujiElectric TS1070/TS1071 series HMI
Introduction: FujiElectric TS1070/TS1071 series Human Machine Interface (HMI) Display Size 7 inch widescreen Display resolution 800×480 dots Display device TFT color Display color 65.536 colors Brightness 450 cd
Product Picture Show:
...
|
|
FujiElectric FSC Portable Ultrasonic Flow Meter
FujiElectric FSC Portable Ultrasonic Flow Meter
peculiarity
An SD memory card can be used to store data for long-term measurements
With calorie consumption function
Rely on battery power for 12 hours of continuous work
With printer (optional ...
|
|
FujiElectric ZSVS small gas analyzer
FujiElectric ZSVS small gas analyzer
peculiarity
It is suitable for measuring CO, CO2, CH4 and O2 gas concentrations in heat treatment furnaces and plant cultivation and chemical analysis ·.
It is possible to measure the gas concentration of up to 4 components simultaneously and continuously.
|
|
FujiElectric ZPG Single Beam Infrared Gas Analyzer
FujiElectric ZPG Single Beam Infrared Gas Analyzer
peculiarity
High stability: zero drift±0.5%FS/week.
Installed in a 19-inch cabinet, it weighs about 9kg, making it compact and lightweight.
Enables continuous measurement of low gas concentrations.
...
|
|
FujiElectric ZFP infrared CO2 controller
FujiElectric ZFP infrared CO2 controller
Main specifications:
This article introduces FujiElectric ZFP infrared CO2 controller products, if you are interested in FujiElectric controller, please also contact our staff ...
|
|
FujiElectric ZKG Magnetic Oxygen Analyzer
FujiElectric ZKG Magnetic Oxygen Analyzer
peculiarity
Magnetic method (pressure detection type) eliminates the need for auxiliary gases.
The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases.
Almost unaffected by other ...
|
|
FujiElectric UG30 Series POD
Introduction: FujiElectric UG30 series POD
Product Introduction
■Features
●Compatible with 32,768 color displays
It can handle 32,768 color displays, and the display effect is the same as that of photos.
●AV functions are substantial
Video input ...
|
|
FujiElectric ZKM zirconia gas analyzer
Introduction: FujiElectric ZKM zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
4~7 seconds of rapid ringing ...
|
|
FujiElectric FWD Air Ultrasonic Flow Meter
FujiElectric FWD Air Ultrasonic Flow Meter
peculiarity
Suitable for a variety of pipe diameters to meet your needs.
Suitable for diameter 25mm~200mm.
There is no pressure loss, and zero energy loss is realized.
This product adopts ultra...
|
|
FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
Introduction: FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for combustion control.
It is possible to open the case without opening the shell.
|
|