FujiElectric FLR compact ultrasonic flowmeter
peculiarity
Standard accuracy of 1.5% of rate (optional 1% of rate)
Fast response in just 0.2 seconds
There is no need to open the inverter housing, and the setting can be operated from the front
RS-485 communication function (optional)
PC loader software is standard
Main specifications:Model | Transformer FSV Detector FSS | Applicable pipe diameter | Inner diameter 25~225mm (detector: FSSA)
Inner diameter 50~1200mm (detector: FSSC) | Piping material | Plastics (PVC, PVDF, PP, etc.), metals | Measuring range | 0~±0.3 ????? ±10m/s | precision | ±1.5% of rate or ± 1.0% of rate (for flow rate of 2 m/s or more) | Responsiveness | 0.2s (in high-speed response mode) | Fluid temperature | -20~+100°C (Detector FSSA)
-40~+120°C (Detector FSSC) | Ambient temperature | -20~+50°C (converter), -20~+60???? 80 °C (depending on detector) | Analog output | DC4~20mA, 1 point (Load resistance: 600Ω max.) | Contact output | Open collector output: 2 points, total, alarm, etc
1P/day~100P/s (open collector) | Serial transmission | RS-485/MODBUS (option) | display | LCD (2-line, 16-bit) with backlight | keyboard | 4 keys (Esc, Up, Shift, Enter) | Supply voltage | AC100~240V, 50/60Hz or DC20~30V | Inverter housing model | Aluminum alloy, IP65 | How to install the converter | Wall mounting or pipe installation | Transformer dimensions | H140×W137×D68mm(IP65) |
This article describes:FLRproducts, if you are interested in RKC, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow!
|
More on that
|
FujiElectric UG20 Series POD
Introduction: FujiElectric UG20 series POD
Product Introduction
●I adopt medium-to-large 7.7 inches of 128-color STN color LCD
7.7 type VGA (640 480 dots) 128 colors STN display color liquid ...
|
|
FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI)
Introduction: FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI) supports remote operation through VNC server function, and supports various specifications as standard, and the FROM capacity has been greatly expanded by 2.2 times.
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZFK8 zirconia gas analyzer
Introduction: FujiElectric ZFK8 zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for burning ...
|
|
FujiElectric ZRJ Infrared Gas Analyzer
FujiElectric ZRJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NO, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Up to 4 components of the gas concentration ...
|
|
FujiElectric V9100iC Human Machine Interface (HMI)
Introduction: FujiElectric V9100iC Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
...
|
|
FujiElectric FSC Portable Ultrasonic Flow Meter
FujiElectric FSC Portable Ultrasonic Flow Meter
peculiarity
An SD memory card can be used to store data for long-term measurements
With calorie consumption function
Rely on battery power for 12 hours of continuous work
With printer (optional ...
|
|
FujiElectric ZKM zirconia gas analyzer
Introduction: FujiElectric ZKM zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
4~7 seconds of rapid ringing ...
|
|
FujiElectric ZAF Thermal Conductivity Gas Analyzer
FujiElectric ZAF Thermal Conductivity Gas Analyzer
peculiarity
Large, easy-to-see LCD display.
Can communicate with a computer.
Compact panel mounting structure.
Automatic correction function for zero point and full-scale point (optional)
|
|
FujiElectric FWD Air Ultrasonic Flow Meter
FujiElectric FWD Air Ultrasonic Flow Meter
peculiarity
Suitable for a variety of pipe diameters to meet your needs.
Suitable for diameter 25mm~200mm.
There is no pressure loss, and zero energy loss is realized.
This product adopts ultra...
|
|
FujiElectric ZRE Infrared Gas Analyzer
FujiElectric ZRE Infrared Gas Analyzer
peculiarity
It adopts a single beam type, which is compact and easy to maintain.
Excellent long-term stability.
The large LCD screen is used to make it clearer and more eye-catching, and easy to operate.
...
|
|
FujiElectric ZKJ Infrared Gas Analyzer
FujiElectric ZKJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NOx, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Up to 5 components of the gas concentration can be continuously ...
|
|
FujiElectric V9150iX Human Machine Interface (HMI)
Introduction: FujiElectric V9150iX Human Machine Interface (HMI) 15-inch, TFT, 16.7M Color, XGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZAJ Magnetic Oxygen Analyzer
FujiElectric ZAJ Magnetic Oxygen Analyzer
Main specifications:
We always adhere to the business philosophy: "to provide a full range of high-quality services, supply high-quality products, mutual benefit and win-win, integrity ...
|
|
FujiElectric UG30 Series POD
Introduction: FujiElectric UG30 series POD
Product Introduction
■Features
●Compatible with 32,768 color displays
It can handle 32,768 color displays, and the display effect is the same as that of photos.
●AV functions are substantial
Video input ...
|
|
FujiElectric PHN Paperless Recorder
Introduction: FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver Compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording
Product Picture Show:
Give birth...
|
|
FujiElectric ZSS in-line laser gas analyzer
FujiElectric ZSS in-line laser gas analyzer
peculiarity
Analyzer for HCL, NH3, O2, CO, CO2, CH4 gas concentration measurement.
Due to the fast response speed (less than 1~5 seconds), it can be assembled into the control system.
|
|
FujiElectric V9100iS Human Machine Interface (HMI)
Introduction: FujiElectric V9100iS Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric FSH hybrid ultrasonic flowmeter
FujiElectric FSH hybrid ultrasonic flowmeter
peculiarity
The automatic switching between the pulse Doppler method using ultrasonic reflection characteristics and the propagation time difference method using ultrasonic penetration characteristics can be applied to a wide range of ...
|
|
FujiElectric ZFP infrared CO2 controller
FujiElectric ZFP infrared CO2 controller
Main specifications:
This article introduces FujiElectric ZFP infrared CO2 controller products, if you are interested in FujiElectric controller, please also contact our staff ...
|
|
FujiElectric ZKG Magnetic Oxygen Analyzer
FujiElectric ZKG Magnetic Oxygen Analyzer
peculiarity
Magnetic method (pressure detection type) eliminates the need for auxiliary gases.
The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases.
Almost unaffected by other ...
|
|