FujiElectric ZKJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NOx, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Gas concentrations of up to 5 components can be measured continuously and simultaneously.
With mass-flow, it is virtually unaffected by other gases.
It has a variety of functions such as automatic correction, O2 conversion output, average value output, and alarm.
The large, easy-to-see liquid crystal display enables simultaneous monitoring of concentration changes in five components.
The 19-inch cabinet mounting structure makes it easy to build a gas analysis system.
There are two types of instruments for measuring O2: a built-in magnetic oxygen analyzer and a zirconia oxygen analyzer sold separately.
The maximum volume ratio is 1:25, and the range can be set and changed freely within the specified range.
Main specifications:
Measuring principle | Non-dispersive infrared methods: NOX, SO2, CO, CO2, CH4
Magnetic method: O2 (built-in)
Zirconia method: O2 (Model: External ZFK7) | Measure the components | One group: NOX, SO2, CO, CO2, CH4
Two components: NOX+SO2, NOX+CO, CO2+CO
Three components: NOX+SO2+CO
Four components: NOX+SO2+CO+CO2
(CH4 can also be combined)
O2 can be attached to each component. | Measuring range | NOX :0~50ppm···5000ppm
SO2:0~50ppm···10%
CO:0~50ppm···100%
CO2:0~20ppm···100%
CH4:0~200ppm···100%
O2:0~5%···25% | repeatability | ±0.5%FS (±1%FS up to 50ppm) | Zero drift | Not more than ±1.0% FS/week
(50ppm~200ppm is ±2%FS/week or less, 50ppm or less is ±2%FS/day) | Full-scale drift | Not more than ±2.0% FS/week (±2.0% FS/day below 50ppm) | Linearity | ±1.0%FS | Response time | Within 60 seconds (90% response), specimen gas 0.5 L/min) | Output signal | - Each DC4~20mA (linear) or DC0~1V (linear)
(Instantaneous value output for each measured concentration, O2 conversion instantaneous value, O2 conversion average, O2 average value) - Contact output (CO peak count/alarm, concentration upper and lower limit alarm, automatic calibration, when the instrument is abnormal, range identification, correction abnormality, etc.)
| Contact input | Automatic calibration start, average value reset, range switching, average value reset, pump OFF, etc | function | Automatic calibration, O2 conversion calculation, average value calculation, CO peak count/alarm, output signal hold, etc | Environmental conditions | -5~+40°C, no more than 90%RH | Supply voltage | AC100~240V 50/60Hz、250VA | Dimensions | 483(W)×177(H)×578(D)mm | Standard measurements
Gas conditions | temperature | 0~50℃ | flow rate | 0.5L/min±0.2L/min | dust | Particles not exceeding 1 m, not exceeding 100 g/Nm3 | pressure | Not more than 10kPa (the gas outlet side should be atmospheric pressure) | Aerosol | not | Corrosive components | No more than 1ppm | moisture content | Saturation not exceeding 2°C (should be free of condensation) |
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow!
In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
FujiElectric V9120iS Human Machine Interface (HMI)
Description: FujiElectric V9120iS Human Machine Interface (HMI) 12.1 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric PHN Paperless Recorder
Introduction: FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver Compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording
Product Picture Show:
Give birth...
|
|
FujiElectric V9080iC Human Machine Interface (HMI)
Introduction: FujiElectric V9080iC HMI 8.4 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
Above...
|
|
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
peculiarity
Gas analyzer for measuring ambient gas concentration in heat treatment furnaces.
Precise measurement of the gas concentration in the furnace
Repeatability: ±0.5%
...
|
|
FujiElectric TS1070/TS1071 series HMI
Introduction: FujiElectric TS1070/TS1071 series Human Machine Interface (HMI) Display Size 7 inch widescreen Display resolution 800×480 dots Display device TFT color Display color 65.536 colors Brightness 450 cd
Product Picture Show:
...
|
|
FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
Introduction: FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for combustion control.
It is possible to open the case without opening the shell.
|
|
FujiElectric V9071iW Human Machine Interface (HMI)
Introduction: FujiElectric V9071iW Human Machine Interface (HMI) 7-inch, TFT, 16.7M Color, WVGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F
Product Picture Show:
Specifications:
The above introduction ...
|
|
FujiElectric ZFP infrared CO2 controller
FujiElectric ZFP infrared CO2 controller
Main specifications:
This article introduces FujiElectric ZFP infrared CO2 controller products, if you are interested in FujiElectric controller, please also contact our staff ...
|
|
FujiElectric FSV Ultrasonic Flowmeter
FujiElectric FSV Ultrasonic Flowmeter
peculiarity
High-precision measurement of 1.0% of rate
High-speed measurement in 0.2 seconds
It is a compact inverter with a front size of 142×170 mm
Adopt an anti-bubble measurement method with excellent anti-bubble ability
There is no need to open the cover of the converter ...
|
|
FujiElectric ZSVS small gas analyzer
FujiElectric ZSVS small gas analyzer
peculiarity
It is suitable for measuring CO, CO2, CH4 and O2 gas concentrations in heat treatment furnaces and plant cultivation and chemical analysis ·.
It is possible to measure the gas concentration of up to 4 components simultaneously and continuously.
|
|
FujiElectric ZAFE Pressure-Resistant Explosion-proof Thermal Gas Analyzer
FujiElectric ZAFE Pressure-Resistant Explosion-proof Thermal Gas Analyzer
peculiarity
NEPSI certified qualified product (Exd II.C T6Gb).
Large, easy-to-see LCD display.
Can communicate with a computer.
Small panels ...
|
|
FujiElectric PPU large paperless recorder
Introduction: FujiElectric PPU Large Paperless Recorder, 300×300mm Front Size Up to 36 points can be recorded for up to 12 types of thermocouples, 2 types of temperature resistors, and voltage/current input signals.
Product Picture Show:
...
|
|
FujiElectric ZAF Thermal Conductivity Gas Analyzer
FujiElectric ZAF Thermal Conductivity Gas Analyzer
peculiarity
Large, easy-to-see LCD display.
Can communicate with a computer.
Compact panel mounting structure.
Automatic correction function for zero point and full-scale point (optional)
|
|
FujiElectric V9060iT Human Machine Interface (HMI)
Introduction: FujiElectric V9060iT HMI 15.1-inch, TFT, 64K color, 3-ch serial, CF, A·· B USB, communication I/F built-in, XGA
Product Picture Show:
Specifications:
The above ...
|
|
FujiElectric ZKG Magnetic Oxygen Analyzer
FujiElectric ZKG Magnetic Oxygen Analyzer
peculiarity
Magnetic method (pressure detection type) eliminates the need for auxiliary gases.
The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases.
Almost unaffected by other ...
|
|
FujiElectric ZFK8 zirconia gas analyzer
Introduction: FujiElectric ZFK8 zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for burning ...
|
|
FujiElectric PHA inkjet recorder
Introduction: FujiElectric PHA inkjet recorder is a 180mm paper width recorder with 6 colors of inkjet, vivid recording, and inkjet method. Thermocouples, temperature resistors, and voltage/current signals are used as inputs
Product Picture Show:
Key Specifications:
...
|
|
FujiElectric PHE inkjet recorder
Introduction: FujiElectric PHE inkjet recorder with 6-color vivid recording / inexpensive type, abundant measurement objects, compact size, ideal for assembly into machinery and equipment, high-quality recording
Product Picture Show:
Product Features and Advantages:
...
|
|
FujiElectric TS1100/TS1101 series HMI
Introduction: FujiElectric TS1100/TS1101 series Human Machine Interface (HMI) Display Size 10.2 inch widescreen Display resolution 800×480 dots Display device TFT color Power consumption 16w
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZAJ Magnetic Oxygen Analyzer
FujiElectric ZAJ Magnetic Oxygen Analyzer
Main specifications:
We always adhere to the business philosophy: "to provide a full range of high-quality services, supply high-quality products, mutual benefit and win-win, integrity ...
|
|