FujiElectric ZAF Thermal Conductivity Gas Analyzer
peculiarity
Large, easy-to-see LCD display.
Can communicate with a computer.
Compact panel mounting structure.
Automatic correction function for zero and full-scale points (optional).
Compensating for the interference effects of other gases (optional).
Gas concentration alarm output (optional)
You can select one of the upper · lower limit alarm, upper · upper limit alarm, and lower · lower limit alarm output.
Range switching (optional)
Switching mode operated by front keypad or input via external contact. Measuring range ratio: 1:10 for H2 and He, 1:5 for Ar, CH4 and CO2.
Linearization of the measurement output signal (optional)
use
H2 gas concentration measurement in semiconductor devices
H2 gas concentration measurement in a hydrogen generator
H2 gas concentration measurement in a sintering furnace
Measurement of Ar, He, and CH4 concentrations in gas generators
Measurement of He gas concentration in a superconducting device
Measurement of Ar gas concentration in air separation plants
Measuring principle
Thermal conductivity gas analyzers measure gas concentrations using the different thermal conductivity of two component gases. Inside the detector there is a reference chamber and a measuring chamber, and the inside is tensioned with fine platinum wires. The reference chamber is sealed with a reference (reference) gas. The platinum wire is combined with an external fixed-value resistor to form a bridge loop, and a constant current flows through each platinum wire to make it heat. If there is a change in the concentration of the measured component, the thermal conductivity of the sample gas will change accordingly, which will change the temperature of the platinum wire in the measuring chamber. By taking this temperature change in the form of a change in resistance value, the concentration of the measured gas can be calculated.
Main specifications:Standard Specifications | Measurement method | Thermally conductive | Measure the components | He、Ar、H2、CH4、CO2 | Measuring range | H2:0~3……100%,100~90,100~80%
He:0~5……100%,100~90,100~80%
Ar:0~10……100%,100~90,100~80%
CH4:0~20……100%,100~80% | Output signal | DC4~20mA, DC0~1V, DC0~10mV non-isolated output (one point, depending on the model) | Allowable load resistance | Up to 550Ω (when DC4~20mA output) | Output resistance | 100kΩ (at DC0~1V, DC0~10mV) | display | With backlit LCD | Measured values are displayed | Up to 4 digits or 2 decimal places | The output signal is maintained | The output value before correction is maintained during manual correction and automatic correction | Power supply voltage, power consumption | AC100~240V 50/60Hz, approx. 50VA | Ambient temperature, humidity | -5~45°C, no more than 90%RH (no condensation) | Installation method: | Panel recessed | Dimensions(H×W×D) | 240×192×213mm | weight | Approximately 5kg | Enclosure type | Sheet steel shell, indoor type | Gas inlet and outlet, ventilation port | Rc1/4 or NPT1/4 (as specified) | The flow rate of the ventilation gas | Approx. 1 L/min (as required) | Applicable Standards | CE marking (scheduled to obtain certification) | performance | repeatability | ±1%FS | drift | Zero point: within ±2% FS/week (H2 analyzer)
Full Scale Point: Within ±2% FS/week (H2 Analyzer) | Responsiveness (90% response) | Standard: Within 60 seconds (0.4L/min flow)
High speed: less than 10 seconds (1L/min flow)
However, only for H2 analyzer (reference gas is N2) | Standard measurement of gas conditions | temperature | 0~50℃ | Gas flow | 0.4±0.05 L/min and should be stable | dust | Particles not exceeding 1 m, not exceeding 100 g/Nm3 | pressure | No more than 10kPa | Aerosols, corrosive gases | not | moisture content | Do not saturate at more than 2 °C | Optional Accessory Specifications | linearization | Additional linearization of the output signal (DC4~20mA) of the measured value
Straightness does not exceed ±2%FS | Relay contact output | 5 points of 1a output
Relay contact capacity: AC220V/2A (resistive load)
Relays are isolated from each contact and from the internal circuit
You can select up to 5 of the following functions- The automatic correction uses a zero solenoid valve to drive the output
- The output is driven by a full-scale solenoid valve for automatic correction
- The suction pump is OFF output during automatic calibration
- Upper limit (1 point) concentration alarm output
- Lower limit (1 point) concentration alarm output
- Upper and lower limit (1 point) concentration alarm output
- Upper (1 point) and lower (1 point) concentration alarm output
- Upper limit 2 segments (1 point each) concentration alarm output
- The lower limit is 2 segments (1 point each) concentration alarm output
- Analyzer abnormality or automatic correction abnormal alarm output
- Output in correction
- Measuring range information output
| Contact input | 3 non-voltage contact inputs
ON: 0 V, OFF: 5 mA at DC5 V, ON
It is isolated from the internal circuit by optocoupler, and the contact input is not isolated
You can enter the following three points- Remote measured value output hold
- Remote range switching (dual-range analyzer only)
- Remote auto-correction begins
| Input of interferometric gas measurements | H2 Analyzer Analog Input for Interferometry (DC1~5V)
Input a component of CO2 or CH4 from an external gas analyzer.
It needs to be adjusted at our factory. Confirm the details of the gas to be measured at the time of ordering. | Auto-correction function | Zero-point and full-scale corrections are performed automatically according to pre-set cycles. The solenoid valve is actuated externally, and the correction gas flows sequentially. | Communication features | RC232C (9-pin D-sub output)
Half-duplex bit continuous asynchronous periodic formula
MODBUS protocol, communication speed 9600bps
Communication contents: Measurement concentration value, reading and writing of various set values, instrument status output |
We always adhere to the business philosophy: "to provide a full range of high-quality services, supply high-quality products, mutual benefit and win-win, integrity to others." This is also the belief that all the staff of our company adhere to.
Welcome to negotiate and communicate! Your choice is an affirmation for us.
|
More on that
|
FujiElectric FLR compact ultrasonic flowmeter
FujiElectric FLR compact ultrasonic flowmeter
peculiarity
Standard accuracy of 1.5% of rate (optional 1% of rate)
Fast response in just 0.2 seconds
It is not necessary to open the inverter housing, and it can be accessed from ...
|
|
FujiElectric FSV Ultrasonic Flowmeter
FujiElectric FSV Ultrasonic Flowmeter
peculiarity
High-precision measurement of 1.0% of rate
High-speed measurement in 0.2 seconds
It is a compact inverter with a front size of 142×170 mm
Adopt an anti-bubble measurement method with excellent anti-bubble ability
There is no need to open the cover of the converter ...
|
|
FujiElectric PHC type 6 color inkjet recorder
Introduction: FujiElectric PHC type 6 color inkjet recorder, inkjet method 100mm paper width recorder, clear recording, thermocouple, temperature measurement resistance, voltage/current signal as input
Product Picture Show:
Main features of the product:
...
|
|
FujiElectric ZEME Pressure-Resistant and Explosion-proof Gas Analyzer
Introduction: FujiElectric ZKME Pressure-Resistant and Explosion-proof Gas Analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds ...
|
|
FujiElectric ZSS in-line laser gas analyzer
FujiElectric ZSS in-line laser gas analyzer
peculiarity
Analyzer for HCL, NH3, O2, CO, CO2, CH4 gas concentration measurement.
Due to the fast response speed (less than 1~5 seconds), it can be assembled into the control system.
|
|
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
peculiarity
Gas analyzer for measuring ambient gas concentration in heat treatment furnaces.
Precise measurement of the gas concentration in the furnace
Repeatability: ±0.5%
...
|
|
FujiElectric V9120iS Human Machine Interface (HMI)
Description: FujiElectric V9120iS Human Machine Interface (HMI) 12.1 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric V9100iC Human Machine Interface (HMI)
Introduction: FujiElectric V9100iC Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZFK8 zirconia gas analyzer
Introduction: FujiElectric ZFK8 zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for burning ...
|
|
FujiElectric V9101iW Human Machine Interface (HMI)
Introduction: FujiElectric V9101iW Human Machine Interface (HMI) 10.1", TFT, 16.7M Color, WSVGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F, LAN 2ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric PHE inkjet recorder
Introduction: FujiElectric PHE inkjet recorder with 6-color vivid recording / inexpensive type, abundant measurement objects, compact size, ideal for assembly into machinery and equipment, high-quality recording
Product Picture Show:
Product Features and Advantages:
...
|
|
FujiElectric ZSVS small gas analyzer
FujiElectric ZSVS small gas analyzer
peculiarity
It is suitable for measuring CO, CO2, CH4 and O2 gas concentrations in heat treatment furnaces and plant cultivation and chemical analysis ·.
It is possible to measure the gas concentration of up to 4 components simultaneously and continuously.
|
|
FujiElectric ZKM zirconia gas analyzer
Introduction: FujiElectric ZKM zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
4~7 seconds of rapid ringing ...
|
|
FujiElectric V9100iS Human Machine Interface (HMI)
Introduction: FujiElectric V9100iS Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZKG Magnetic Oxygen Analyzer
FujiElectric ZKG Magnetic Oxygen Analyzer
peculiarity
Magnetic method (pressure detection type) eliminates the need for auxiliary gases.
The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases.
Almost unaffected by other ...
|
|
FujiElectric ZKJ Infrared Gas Analyzer
FujiElectric ZKJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NOx, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Up to 5 components of the gas concentration can be continuously ...
|
|
FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
Introduction: FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for combustion control.
It is possible to open the case without opening the shell.
|
|
FujiElectric UG20 Series POD
Introduction: FujiElectric UG20 series POD
Product Introduction
●I adopt medium-to-large 7.7 inches of 128-color STN color LCD
7.7 type VGA (640 480 dots) 128 colors STN display color liquid ...
|
|
FujiElectric TS1100/TS1101 series HMI
Introduction: FujiElectric TS1100/TS1101 series Human Machine Interface (HMI) Display Size 10.2 inch widescreen Display resolution 800×480 dots Display device TFT color Power consumption 16w
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZAJ Magnetic Oxygen Analyzer
FujiElectric ZAJ Magnetic Oxygen Analyzer
Main specifications:
We always adhere to the business philosophy: "to provide a full range of high-quality services, supply high-quality products, mutual benefit and win-win, integrity ...
|
|