FujiElectric FSH hybrid ultrasonic flowmeter
peculiarity
The automatic switching between the pulsed Doppler method, which utilizes ultrasonic reflection characteristics, and the propagation time difference method, which utilizes ultrasonic penetration, can be applied to a wide range of liquids, regardless of whether bubbles or particles are mixed with them.
The volumetric flow rate of the liquid flowing through the piping is measured with a high accuracy of 0.5%~1%.
When measuring using the pulsed Doppler method, the distribution of the flow velocity can be displayed in real time via a computer (optional).
High-speed response: 0.2 sec/pulse Doppler method
0.5 sec/propagation time difference method
A clamp-on detector that does not require piping is used
Dual measuring lines are also available
Main specifications:
Applicable fluids | Determination of fluids | A homogeneous liquid that can be penetrated by ultrasound
Crude oil, drainage, slurry fluids, dyes, soy milk, etc | The temperature of the fluid | -40~100°C (Small Aperture Sensor)
-40~80°C (other sensors) | Applicable piping | Piping diameter | [td]Caliber (inner diameter) | Verifier model | Φ50~Φ100mm | FLWS12 | Φ100~Φ200mm | FLWS21 | Φ200~Φ500mm | FLWS40 | Φ500~Φ1000mm | FLWS50 |
| Piping material | Plastics (PVC, FRP, etc.), metals (steel pipes, stainless steel pipes, copper pipes, aluminum pipes, etc.) | Lining material | Asphalt epoxy, mortar, etc | performance | precision | [td]manner | Caliber (inner diameter) mm | Flow rate range | precision | Pulsed Doppler method | Φ50~Φ100mm | 1.5m/s~4m/s | ±0.5% of rate | 0m/s~1.5m/s | ±0.0075m/s | Φ100~Φ1000mm | 1m/s~4m/s | ±1.0% of rate | 0m/s~1m/s | ±0.01%m/s | Mode of propagation time difference | Φ13~Φ50 or less | 2m/s~32m/s | ±1.5% of rate | 0m/s~2m/s | ±0.03m/s | Φ50~Φ300 or less | 2m/s~32m/s | ±1.0% of rate | 0m/s~2m/s | ±0.02m/s | Φ30~Φ6000 or less | 1m/s~32m/s | ±1.0% of rate | 0m/s~1m/s | ±0.01m/s |
| Response time | 0.2 sec (pulsed Doppler method)
0.5 sec (propagation time difference method) | Measurement range | 0~±0.3m/s~4m/s (Pulse Doppler method) → 0~±0.3m/s~±4m/s (Pulse Doppler method)
0~±0.3m/s~32m/s (propagation time difference method) → 0~±0.3m/s~±32m/s (propagation time difference method) | Verifiers | class | Small aperture sensor (model: FSWS12 )
Miniature sensor (model: FSWS21)
Medium Sensor (Model: FSWS40)
Large sensor (model: FSWS50)
| Installation method: | Mounting by wrapping stainless steel strip around the outside of the piping (Z-method installation) | connect | The maximum connection cable between the detector and the converter is 150 m | Inverter | Installation method: | Wall mounting | Supply voltage | AC100~240V 50/60Hz or DC20~30V | Analog output | DC4~20mA | Contact output | Relay contact (1 point), transistor output (2 points)
It can be arbitrarily assigned to the positive direction accumulation, reverse direction accumulation, alarm, action range, and flow switch | Communication features | RS485, RS232C (toggle selection) | Display Department | Graphic LCD (with backlight), 240×64 dot matrix | Standard features | Display language | Japanese (kanji, hiragana), English, French, monolingual, Spain (optional) | Measurement display | Instantaneous flow rate/instantaneous flow rate display (10 digits) and cumulative value display (10 digits)
Setting of various flow units. | Forward dual range | Two ranges in the positive direction can be set arbitrarily and the contact output can be performed | Flow switch | The upper and lower limit values can be arbitrarily set and the contact output can be performed | Accumulation switch | The upper limit of the cumulative value can be set arbitrarily and the contact output can be performed | Low-flow cut-off | 0~5m/s | damping | It can be set for analog output and flow/flow rate display | other | Forward and reverse range setting, output over-range, zero point adjustment, etc | Options | Flow velocity distribution output (computer software included, computer separately prepared)
Temperature measurement at the sensor wedge (temperature sensor cable is prepared separately)
Dual measuring lines (with 2 sets of cables for connecting detectors) | weight | Inverter | Approximately 5kg | Detectors | Approximately 1.2kg~3.2kg | structure | Inverter | IP67 (immersion proof), non-explosion-proof | Detectors | IP67 (immersion proof), non-explosion-proof |
The company adheres to the concept of quality first, customer first, integrity-based, and advocates the concept of harmonious cooperation and development with our customers sincerely.
Your choice is our driving force.
76 Technology gives you the best quality service and looks forward to your call.
|
More on that
|
FujiElectric V9080iC Human Machine Interface (HMI)
Introduction: FujiElectric V9080iC HMI 8.4 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
Above...
|
|
FujiElectric PHE inkjet recorder
Introduction: FujiElectric PHE inkjet recorder with 6-color vivid recording / inexpensive type, abundant measurement objects, compact size, ideal for assembly into machinery and equipment, high-quality recording
Product Picture Show:
Product Features and Advantages:
...
|
|
FujiElectric ZSS in-line laser gas analyzer
FujiElectric ZSS in-line laser gas analyzer
peculiarity
Analyzer for HCL, NH3, O2, CO, CO2, CH4 gas concentration measurement.
Due to the fast response speed (less than 1~5 seconds), it can be assembled into the control system.
|
|
FujiElectric ZAJ Magnetic Oxygen Analyzer
FujiElectric ZAJ Magnetic Oxygen Analyzer
Main specifications:
We always adhere to the business philosophy: "to provide a full range of high-quality services, supply high-quality products, mutual benefit and win-win, integrity ...
|
|
FujiElectric ZSVS small gas analyzer
FujiElectric ZSVS small gas analyzer
peculiarity
It is suitable for measuring CO, CO2, CH4 and O2 gas concentrations in heat treatment furnaces and plant cultivation and chemical analysis ·.
It is possible to measure the gas concentration of up to 4 components simultaneously and continuously.
|
|
FujiElectric V9100iC Human Machine Interface (HMI)
Introduction: FujiElectric V9100iC Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZPG Single Beam Infrared Gas Analyzer
FujiElectric ZPG Single Beam Infrared Gas Analyzer
peculiarity
High stability: zero drift±0.5%FS/week.
Installed in a 19-inch cabinet, it weighs about 9kg, making it compact and lightweight.
Enables continuous measurement of low gas concentrations.
...
|
|
FujiElectric ZKJ Infrared Gas Analyzer
FujiElectric ZKJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NOx, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Up to 5 components of the gas concentration can be continuously ...
|
|
FujiElectric V9120iS Human Machine Interface (HMI)
Description: FujiElectric V9120iS Human Machine Interface (HMI) 12.1 inches, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric TS1070/TS1071 series HMI
Introduction: FujiElectric TS1070/TS1071 series Human Machine Interface (HMI) Display Size 7 inch widescreen Display resolution 800×480 dots Display device TFT color Display color 65.536 colors Brightness 450 cd
Product Picture Show:
...
|
|
FujiElectric FSC Portable Ultrasonic Flow Meter
FujiElectric FSC Portable Ultrasonic Flow Meter
peculiarity
An SD memory card can be used to store data for long-term measurements
With calorie consumption function
Rely on battery power for 12 hours of continuous work
With printer (optional ...
|
|
FujiElectric PHN Paperless Recorder
Introduction: FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver Compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording
Product Picture Show:
Give birth...
|
|
FujiElectric ZKM zirconia gas analyzer
Introduction: FujiElectric ZKM zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
4~7 seconds of rapid ringing ...
|
|
FujiElectric ZPA Single Beam Infrared Gas Analyzer
FujiElectric ZPA Single Beam Infrared Gas Analyzer
peculiarity
Mounted in a 19-inch cabinet, it weighs about 10kg, making it compact and lightweight.
Enables continuous measurement of the concentration of up to 5 gases.
Built-in magnetic or electrochemical oxygen ...
|
|
FujiElectric ZRJ Infrared Gas Analyzer
FujiElectric ZRJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NO, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Up to 4 components of the gas concentration ...
|
|
FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI)
Introduction: FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI) supports remote operation through VNC server function, and supports various specifications as standard, and the FROM capacity has been greatly expanded by 2.2 times.
Product Picture Show:
Specifications:
...
|
|
FujiElectric PPU large paperless recorder
Introduction: FujiElectric PPU Large Paperless Recorder, 300×300mm Front Size Up to 36 points can be recorded for up to 12 types of thermocouples, 2 types of temperature resistors, and voltage/current input signals.
Product Picture Show:
...
|
|
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
peculiarity
Gas analyzer for measuring ambient gas concentration in heat treatment furnaces.
Precise measurement of the gas concentration in the furnace
Repeatability: ±0.5%
...
|
|
FujiElectric V9071iW Human Machine Interface (HMI)
Introduction: FujiElectric V9071iW Human Machine Interface (HMI) 7-inch, TFT, 16.7M Color, WVGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F
Product Picture Show:
Specifications:
The above introduction ...
|
|
FujiElectric ZKG Magnetic Oxygen Analyzer
FujiElectric ZKG Magnetic Oxygen Analyzer
peculiarity
Magnetic method (pressure detection type) eliminates the need for auxiliary gases.
The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases.
Almost unaffected by other ...
|
|