FujiElectric ZRE Infrared Gas Analyzer
peculiarity
It adopts a single beam type, which is compact and easy to maintain.
Excellent long-term stability.
The large LCD screen is used to make it clearer and more eye-catching, and easy to operate.
It can be used for automatic calibration, upper and lower limit concentration alarms, and remote range switching.
Virtually unaffected by the interference of moisture.
Main specifications:
Measuring principle | NO, SO2, CO, CO2, CH4: Non-dispersive infrared absorption method (single beam type)
O2: Electrochemical formula (built-in) or zirconia type (external ZFK7 type) | Measurement components and measurement ranges | NO:0~200ppm 5000ppm
SO2:0~200ppm 0~10 vol%
CO2:0~100ppm 0~100 vol%
CO:0~200ppm 0~100 vol%
CH4:0~500ppm 0~100 vol%
O2:0~5 vol% 25 vol% (zirconia type)
2 ranges can be switched for each component, with a maximum volume ratio of 1:10 (except O2) | repeatability | ±0.5%FS | Linearity | ±1.0%FS | Zero drift | ±2% FS or less/week | Range drift | ±2% FS or less/week | Response time | Within 60 seconds (90% response to gas inlet and outlet measurements)
(Varies depending on the measurement group score and measurement range) | Analog output signal | DC 4~20mA or DC O~1V (up to 12 points)
Instantaneous value output (gas concentration of each component) | Matching | O2 conversion instantaneous value output, O2 conversion average output, O2 average value output | Display Department | LCD display with backlight (Japanese or English: as specified)
Instantaneous value of each component, O2 conversion instantaneous value, O2 conversion average, O2 average value, parameter set value
With auto-off function | Span-switching method | There are 3 switching methods, including manual switching by operating buttons, automatic switching, and external contact input switching (optional) | External contact input
(Optional) | Voltage input contacts (DC 12~24V applied, maximum current 15mA) up to 9 points
Range switching, auto-correction start, output signal hold, average value reset | Contact output
(Optional) | 1C relay contacts (up to 15 points) of each component range identification, instrument abnormality, correction abnormality
The automatic correction is in the middle and the upper and lower limits of each component alarm, the pump is ON/OFF, and the automatic correction is driven by a solenoid valve | Communication features
(Optional) | RS-485 (MODOBUS PROTOCOL)
Communication content: Reading and writing of various set values, as well as output of measured concentration values and meter status
TYPE-B (FRONT OF THE METER) WITH USB CONNECTOR, ADDITIONAL USB DRIVE | Specimen gas flow meter | Built | Size of gas inlet and outlet | Rc1/4 or NPT1/4 | structure | Indoor, steel plate chassis | Ambient temperature and humidity | -5°C~45°C below 90RH (no condensation) | Installation method: | 19-inch cabinet mounted, recessed panel, desktop (as specified by model) | Supply voltage | AC 100V~240V 50/60Hz,100VA | Dimensions
(H×W×D) | 133×483×418mm (19" cabinet mounted)
133×440×418mm (panel recessed)
149×440×418mm (Desktop) | weight | Approx. 8 kg (when using a five-component analyzer) | Applicable Standards | CE marked |
The company respects the enterprise spirit of "practicality, hard work and responsibility", and creates a good corporate environment with integrity, win-win, and business philosophy, and takes a new management model, perfect technology, thoughtful service, and excellent quality as the foundation for survival. We always adhere to: customer first, serve customers attentively, and insist on impressing customers with their own services. Always adhering to the business philosophy of "integrity, win-win", relying on excellent prices, excellent quality, fast delivery and pre-sales consultation and after-sales service to win the trust of our customers.
|
More on that
|
FujiElectric ZPB Single Beam Infrared Gas Analyzer
FujiElectric ZPB Single Beam Infrared Gas Analyzer
peculiarity
High stability: zero drift±0.5%FS/week.
Mounted in a 19-inch cabinet, it weighs about 11kg, making it compact and lightweight.
Capable of continuous measurement of up to 5 gases ...
|
|
FujiElectric V9100iS Human Machine Interface (HMI)
Introduction: FujiElectric V9100iS Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZAJ Magnetic Oxygen Analyzer
FujiElectric ZAJ Magnetic Oxygen Analyzer
Main specifications:
We always adhere to the business philosophy: "to provide a full range of high-quality services, supply high-quality products, mutual benefit and win-win, integrity ...
|
|
FujiElectric V9080iS Human Machine Interface (HMI)
Introduction: FujiElectric V9080iS HMI 8.4-inch, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
FujiElectric Infrared gas analyzer for ZFG heat treatment furnace
peculiarity
Gas analyzer for measuring ambient gas concentration in heat treatment furnaces.
Precise measurement of the gas concentration in the furnace
Repeatability: ±0.5%
...
|
|
FujiElectric ZAFE Pressure-Resistant Explosion-proof Thermal Gas Analyzer
FujiElectric ZAFE Pressure-Resistant Explosion-proof Thermal Gas Analyzer
peculiarity
NEPSI certified qualified product (Exd II.C T6Gb).
Large, easy-to-see LCD display.
Can communicate with a computer.
Small panels ...
|
|
FujiElectric V9100iC Human Machine Interface (HMI)
Introduction: FujiElectric V9100iC Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
...
|
|
FujiElectric FSV Ultrasonic Flowmeter
FujiElectric FSV Ultrasonic Flowmeter
peculiarity
High-precision measurement of 1.0% of rate
High-speed measurement in 0.2 seconds
It is a compact inverter with a front size of 142×170 mm
Adopt an anti-bubble measurement method with excellent anti-bubble ability
There is no need to open the cover of the converter ...
|
|
FujiElectric V9150iX Human Machine Interface (HMI)
Introduction: FujiElectric V9150iX Human Machine Interface (HMI) 15-inch, TFT, 16.7M Color, XGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI)
Introduction: FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI) supports remote operation through VNC server function, and supports various specifications as standard, and the FROM capacity has been greatly expanded by 2.2 times.
Product Picture Show:
Specifications:
...
|
|
FujiElectric PHN Paperless Recorder
Introduction: FujiElectric PHN Paperless Recorder for fast display of past dataStandard equipped with computer support software communication function screen saver Compact specifications 3 points, 6 points, 9 points of recording and up to 12 points of recording
Product Picture Show:
Give birth...
|
|
FujiElectric V9060iT Human Machine Interface (HMI)
Introduction: FujiElectric V9060iT HMI 15.1-inch, TFT, 64K color, 3-ch serial, CF, A·· B USB, communication I/F built-in, XGA
Product Picture Show:
Specifications:
The above ...
|
|
FujiElectric ZSS in-line laser gas analyzer
FujiElectric ZSS in-line laser gas analyzer
peculiarity
Analyzer for HCL, NH3, O2, CO, CO2, CH4 gas concentration measurement.
Due to the fast response speed (less than 1~5 seconds), it can be assembled into the control system.
|
|
FujiElectric ZKG Magnetic Oxygen Analyzer
FujiElectric ZKG Magnetic Oxygen Analyzer
peculiarity
Magnetic method (pressure detection type) eliminates the need for auxiliary gases.
The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases.
Almost unaffected by other ...
|
|
FujiElectric PHA inkjet recorder
Introduction: FujiElectric PHA inkjet recorder is a 180mm paper width recorder with 6 colors of inkjet, vivid recording, and inkjet method. Thermocouples, temperature resistors, and voltage/current signals are used as inputs
Product Picture Show:
Key Specifications:
...
|
|
FujiElectric UG20 Series POD
Introduction: FujiElectric UG20 series POD
Product Introduction
●I adopt medium-to-large 7.7 inches of 128-color STN color LCD
7.7 type VGA (640 480 dots) 128 colors STN display color liquid ...
|
|
FujiElectric ZSVS small gas analyzer
FujiElectric ZSVS small gas analyzer
peculiarity
It is suitable for measuring CO, CO2, CH4 and O2 gas concentrations in heat treatment furnaces and plant cultivation and chemical analysis ·.
It is possible to measure the gas concentration of up to 4 components simultaneously and continuously.
|
|
FujiElectric V9071iW Human Machine Interface (HMI)
Introduction: FujiElectric V9071iW Human Machine Interface (HMI) 7-inch, TFT, 16.7M Color, WVGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F
Product Picture Show:
Specifications:
The above introduction ...
|
|
FujiElectric ZPA Single Beam Infrared Gas Analyzer
FujiElectric ZPA Single Beam Infrared Gas Analyzer
peculiarity
Mounted in a 19-inch cabinet, it weighs about 10kg, making it compact and lightweight.
Enables continuous measurement of the concentration of up to 5 gases.
Built-in magnetic or electrochemical oxygen ...
|
|
FujiElectric FLR compact ultrasonic flowmeter
FujiElectric FLR compact ultrasonic flowmeter
peculiarity
Standard accuracy of 1.5% of rate (optional 1% of rate)
Fast response in just 0.2 seconds
It is not necessary to open the inverter housing, and it can be accessed from ...
|
|