The Siemens 3RM11/3RM13 motor starters have two different protection functions The Siemens 3RM11/3RM13 motor starters have two different protection functions

The 3RM11/3RM13 motor starters include two different protection functions. One protection function is a safety application, and the other is an explosion protection application (ATEX). 1. Functional Safety: Here, the purpose of protection is to identify and control dangerous conditions. In the safe ...

What cable lengths are available between the motor and the soft starters 3RW22, 3RW30, 3RW31, 3RW34, 3RW40, 3RW44 What cable lengths are available between the motor and the soft starters 3RW22, 3RW30, 3RW31, 3RW34, 3RW40, 3RW44

3RW22 (no longer available): With SIKOSTART 3RW22, the maximum permissible cable length between SIKOSTART and the motor is 200m. 3RW30xx-xAAxx 3RW30xx-xABxx, 3RW30xx-xCBxx, 3RW31xx-xCBxx (no longer available): ...

Features of the Siemens S7-1200 memory card Features of the Siemens S7-1200 memory card

The memory card used by the S7-1200 CPU is an SD card, which can store user project files and has the following three functions: As a mount store for the CPU, user project files can be stored only on the card, without project files in the CPU, they cannot run without the memory card. ...

How to erase the password using a memory card How to erase the password using a memory card

If the customer has forgotten the password of the S7-1200 that was previously set, the program and password inside the S7-1200 cannot be erased through "Factory Reset", and the only way to erase the password is to use a memory card. The detailed steps are as follows: Power off the S7-1200 device Insert a ...

Upload user files to a Siemens memory card Upload user files to a Siemens memory card

Upload user files to the memory card   Step 1: Follow the above method to set the memory card to "Program Card" mode. Customers are advised to clear all files from the memory card before doing this. Step 2: Set the boot state of the CPU. Right-click the CPU in the Project Tree and select ...

Siemens loads the item to a memory card in transfer mode Siemens loads the item to a memory card in transfer mode

Mount items to a memory card in transfer mode Step 1: Follow the above method to set the memory card to "Transfer Card" mode. Customers are advised to clear all files from the memory card before doing this. Step 2: Set the boot state of the CPU: In the "Project ...

How to remove the IP address with a SIMATIC MC memory card and reset the S7-1200 to factory settings How to remove the IP address with a SIMATIC MC memory card and reset the S7-1200 to factory settings

You can reset your S7-1200 to factory settings using an empty SIMATIC MC memory card. illustrate Even if you don't have SIMATIC STEP 7 Basic software and don't know the IP address, you can use the SIMATIC MC memory card to delete the IP address and put the S7-1 ...

Update the firmware version of your S7-1200 CPU with a 24M memory card Update the firmware version of your S7-1200 CPU with a 24M memory card

1. Use your computer to erase the contents of the memory card through a card reader. Note: Do not format the memory card! 2. Download the latest version of the firmware file from the official website of Siemens. After downloading and unzipping, you can get a "S7_JOB.SYS" file and a "FWUOPDATE. S7S ...

The 3RA6 SIRIUS Compact Starter operates in conditions from 2000m to 5000m above sea level The 3RA6 SIRIUS Compact Starter operates in conditions from 2000m to 5000m above sea level

When the 3RA6 SIRIUS Compact Starter is operating at altitudes above 2000 m above sea level, the following parameters will be degraded: Rated Current (Ie), Rated Insulation Voltage (Ui) and Rated Operating Short-Circuit Breaking Capacity (ICS) ...

Siemens 3RM Motor Starter - Safety Integrity Level for ATEX Explosion Protection Applications Siemens 3RM Motor Starter - Safety Integrity Level for ATEX Explosion Protection Applications

Questions: Why do the 3RM11/3RM13 motor starters have a safety class of SIL2 for ATEX protection and SIL3 and PLe for functional safety applications? Answer: The 3RM11/3RM13 motor starters include two different protections ...

Advantages of the SINAMICS G120 modular frequency inverter from Siemens Advantages of the SINAMICS G120 modular frequency inverter from Siemens

1. The modular design creates a high degree of flexibility and can be adapted to the future requirements of the drive concept   The control unit can be replaced in the energized state (hot-swappable). Plug-in terminals are used The equipment is easy to replace and easy to maintain 2. Integrated security features, so ...

Industries for which Siemens PM250 power supplies are applicable Industries for which Siemens PM250 power supplies are applicable

The PM250 power modules are suitable for a wide range of applications in the field of general mechanical engineering. This module is able to feed braking energy directly back into the power supply system (four-quadrant applications, no brake chopper required). The PM250 power module is equipped with the world's most advanced Efficient Infeed Tech...

The Siemens CNC Digital Empowerment Center was officially launched in Nanjing The Siemens CNC Digital Empowerment Center was officially launched in Nanjing

The Siemens CNC Digital Empowerment Center (hereinafter referred to as MTS DEAX) was officially launched in Nanjing today. From the original skill use center to the experience and empowerment center, MTS DEAX not only comprehensively demonstrates Siemens' cutting-edge machine tool CNC system processing plan covering the whole value chain, but also ...

Siemens introduces a new generation of industrial Ethernet switches Siemens introduces a new generation of industrial Ethernet switches

At SPS 2022 in Nuremberg, Siemens introduced the new generation of Scalance XC-/XR-300 series Industrial Ethernet switches. With the increasing number of machines, controls and IT systems connected to the network in industrial production, the network at the production level is also ...

Siemens SINAMICS GM150 for in-depth maintenance Siemens SINAMICS GM150 for in-depth maintenance

On-site maintenance Pre-charge circuits, rectifier units, diode characteristics, inverter units, GSV, AVT are inspected and cleaned. Diagnostic testing of rectifier modules, as well as functional testing of high-voltage switchgear interfaces. GM150 IGBT POWERCARD Static Testing, Cleaning, Inspection IG...

Siemens helps Lushan Water Plant achieve smart upgrading Siemens helps Lushan Water Plant achieve smart upgrading

Jiangxi Lushan has a series of halos such as national scenic spots, international cultural heritage, and national 5A-level tourist attractions. Here, water brings spirituality to the mountain, and has also become the source of life for tens of thousands of people in Guling Town, the central scenic area of Lushan Mountain, at an altitude of 1,167 meters. Located in this cloud ...

Siemens signed a strategic cooperation agreement with JD Technology Siemens signed a strategic cooperation agreement with JD Technology

Siemens signed a strategic cooperation agreement with JD Technology today to deepen cooperation in the fields of intelligent power, intelligent parks, and data centers from multiple dimensions such as skills, products, markets, and channels, and work together to build digital and low-carbon benchmark projects in power, parks, industries and other industries.

What is the bypass operation of the 3RW series soft starter? How to choose a bypass contactor? What is the bypass operation of the 3RW series soft starter? How to choose a bypass contactor?

After the 3RW series soft starter is started, there are two main operation methods: continuous operation and bypass operation. At this time, the thyristor is in a fully conductive state, and the system enters a constant speed operation state. Here, we advocate that the user should choose the bypass method to operate, that is, when the starting is completed to reach the full voltage ...

How to choose the right Siemens soft starter according to the load characteristics and user requirements How to choose the right Siemens soft starter according to the load characteristics and user requirements

As a device to control the start/stop of three-phase asynchronous motor, the soft starter is mainly used to effectively reduce the starting current and control the shutdown process. Its main working principle is to control the starting voltage by controlling the conduction angle of the thyristor on the main circuit. Since the starting voltage is close to the starting current, the starting voltage is close to the starting current.

3RW44 How to start and stop the motor by the button next to the LCD screen 3RW44 How to start and stop the motor by the button next to the LCD screen

Step 1: In the third item "Standard Control" in the motor control, select "Button" Step 2: Then in "Control Motor by Button", "Key Control" is selected to activate Step 3: Then in "Control Motor by Button", "Parameter Group", select the parameter ...

Siemens 3RW44 motor rated current and CLASS class setting Siemens 3RW44 motor rated current and CLASS class setting

3RW44 soft starter, when the rated current setting of the motor is inconsistent with the CLASS level, the soft starter will have a fault alarm. Since the 3RW44 has 3 sets of parameter settings, the 3 sets of parameters can be set with different current ratings. However, the CLASS level is set in the "Motor Protection" option, and can only be set ...

Next Page »
12345678Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top