CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A circuit, for long-distance connection and breaking circuits, and can be combined with appropriate thermal overload relays to protect circuits that may occur operating overload.
Comply with standards: GB/T 14048.4, IEC/EN 60947-4-1.
The coil rated control supply voltage Us is:
AC 50Hz, 60Hz, 110V, 127V, 220V, 380V; Mechanical Life:
CJ20-10, 16, 25, 40, 63, 100, 160 is 10 million times, CJ20-250, 400, 630 is 6 million times.
Rated insulation voltage: 690
Agreed free heating current: 315
Number of operating cycles per hour: 600
This article introduces the product interest of CHINT/CHINT CJ20 series AC contactor CJ20-250, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Terminal Appliance UVT-X3 Undervoltage Tripper
Rated working voltage (Ue): AC230V, 50Hz;
Rated insulation voltage (Ui): 500V;
Undervoltage action setting value: (35%-70%) Ue;
Mechanical durability: The mechanical durability of the tripper is 4000 operating cycles.
Tripping characteristics: external voltage≤35%Ue, ...
|
|
CHINT/CHINT Terminal Block-JCUK Series
JCUK series is suitable for wire connection in circuits with AC 50Hz or 60Hz, rated voltage to 1000V and rated cross-sectional area to 150mm2. It is installed on TH35 rails.
Comply with standards: GB/T 14048.7, IEC 60947-7-1.
This article introduces the CHINT/CHINT Terminal Blocks - ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-315-1000
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-40/20
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NPH1 series buttons
NPH1 series push button is suitable for AC 50Hz or 60Hz, rated working voltage to 415V and DC rated voltage to 250V in industrial control circuits, as electromagnetic starters, contactors, relays and other electrical circuit control, with indicator light button is also suitable for light signal indication ...
|
|
CHINT/CHINT Miniature Circuit Breaker NXB-63H has a frequency of 50Hz
Introduction: CHINT/CHINT miniature circuit breaker NXB-63H is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
Forehead...
|
|
CHINT/CHINT OUVT-X1H over/undervoltage tripper
OUVT-X1H over-voltage and under-voltage tripper is suitable for AC 50Hz, rated voltage 230V line, and NBH-63, NBH-40 series circuit breaker matching, when the terminal voltage of the tripper is reduced to the undervoltage protection range or increased to the overvoltage protection range, the tripper acts and drives the circuit breaker to automatically ...
|
|
CHINT/CHINT HY23 Series Reverse Switch HY23-133
HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour.
Rated voltage: 380
Rated current: 30
Control Electricity ...
|
|
CHINT/CHINT NVF3M series mini inverter relay 1 output
Introduction: NVF3M series mini inverter is a high-performance vector control inverter independently developed by our company, which adopts advanced control strategy to achieve high-precision magnetic flux vector torque control, with high control accuracy, wide speed range, large starting torque, high reliability, overload capacity...
|
|
CHINT/CHINT LAY3 series buttons
LAY3 series push buttons are suitable for electromagnetic starters, contactors, relays and other electrical circuits with AC 50Hz or 60Hz, voltage up to 380V and DC voltage up to 220V, for remote control.
Conform to the standard: GB/T 14048.5.
This article introduces the CHINT/CHINT LAY3 series press ...
|
|
CHINT/CHINT Power Distribution Appliance NA8 Series Universal Circuit Breaker
Product Overview
NA8 series universal circuit breaker rated working current from 200A to 7500A, rated limit short-circuit breaking capacity up to 150kA, rated working voltage up to AC1140V, ambient temperature of -45 °C-+70°C, NA8 series universal circuit breaker set height ...
|
|
CHINT/CHINT NA8G series universal circuit breaker
NA8G series universal circuit breaker (referred to as circuit breaker) has a rated current from 200A to 6300A, rated working voltage AC 415V, 690V, suitable for AC 50/60Hz, mainly used in the power distribution network, used to distribute electric energy, protect lines and power supply equipment, so as to protect from overload, undervoltage, short...
|
|
CHINT/CHINT NCH8G Home AC Contactor NCH8G-63/11
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT Ex9ZA series universal transfer switch
The universal transfer switch is mainly suitable for AC 50Hz, rated working voltage 440V and below, DC voltage 240V and below electrical circuits, for manual infrequent connection or breaking of circuits.
It is mainly used for the conversion of various control lines, commutation measurement control of voltmeter and ammeter, and distribution.
|
|
CHINT OUVT-X3H over/undervoltage tripper
OUVT-X3H over-under-voltage tripper is suitable for AC 50Hz, rated voltage 230V line, and NBH-125 series circuit breaker with the use of NBH-125 series circuit breaker, when the terminal voltage of the tripper is reduced to the under-voltage protection range or increased to the over-voltage protection range, the tripper acts and drives the circuit breaker to automatically break, ...
|
|
CHINT/CHINT NB5 miniature circuit breaker
CHINT Xinrui NB5 series terminal power distribution products are suitable for power line facilities and electrical equipment in commercial buildings, residential buildings, industrial equipment and similar places with AC 50Hz, rated voltage of 230V/400V and rated current up to 125A.
|
|
CHINT/CHINT S9 shunt tripper
The S9 shunt trip device (hereinafter referred to as the tripper) is mainly used for matching with NB1 or NBH8 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz (or 60Hz) rated voltage to 400V.
Meets the standard: IEC60947-5-1, obtained CE certification.
3.1 Basic ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/11
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT Terminal Appliances —NU6-III Series Surge Protector
NU6-III series surge protector (hereinafter referred to as surge protector) is used in AC 50Hz, rated working voltage 230V single-phase power distribution system, to meet the SPDIII. test, its open circuit voltage peak to 10kV (1.2/50μs), short circuit current to 5kA (8/20μs), suppress ...
|
|
CHINT/CHINT AX-5 auxiliary contacts
The AX-5 auxiliary contact is suitable for AC 50Hz, the agreed heating current to 6A, the rated voltage to 415V or the DC rated voltage to 130V, and it is assembled with the NL1 residual current action circuit breaker for the signal indication of the long-distance circuit breaker.
Conform to the standard: GB/T 14048.5, ...
|
|