Rexroth hydraulic pump - vane pump heating fault causes and solutions
Analysis of abnormal heating fault of vane pump:
1. The oil temperature is too high 2. The oil cat degree is too large and the internal leakage is too large
3. The working pressure is too high
4. The oil return port is directly connected to the pump population
Abnormal heating elimination method of vane pump:
1. Improve the heat dissipation conditions of the fuel tank or use cooling ...
|
|
How to adjust the pressure and displacement of the hydraulic piston pump?
1. Adjust the displacement of the pump: The larger the displacement of the hydraulic piston pump, the greater the flow and pressure. The displacement can be adjusted by replacing the displacement of the pump or adjusting the eccentricity distance of the pump.
2. Adjust the valves in the hydraulic system: The valves in the hydraulic system can control the flow and pressure.
|
|
Precautions for the use of Rexroth hydraulic pump hydraulic oil
(1) Make sure that the hydraulic oil of Rexroth hydraulic pump is clean and prevent debris from entering the oil. Clean the tank thoroughly when changing the oil and filter it when refueling.
(2) Do not paint the inner wall of the oil tank to prevent precipitation in the oil.
(3) In order to prevent air from entering the hydraulic system, the oil return nozzle should be lower than the tank fluid.
|
|
What are the application ranges of Rexroth oil pumps?
1) Piston pumps are generally used in the hydraulic transmission systems of machine tools, metallurgy, forging, mining and hoisting machinery, and are especially widely used in high-power hydraulic transmission systems.
2) REXROTH vane pumps are generally used in mining, coal, metallurgy, chemical industry, environmental protection and other industries. One...
|
|
Introduction to the basic features of Rexroth piston pumps
Volumetric efficiency (actual discharge/theoretical discharge) rotates at low speed, and internal leakage increases when used at high pressure, and efficiency decreases.
Solid shaft dynamics (theoretical shaft dynamics/mechanical efficiency): number of rotations, increased pressure, increased mechanical efficiency.
Real discharge (volumetric efficiency), real axis power and number of rotations ...
|
|
What are the differences between Rexroth proportional valves and Rexroth servo valves?
First of all, there are no strict regulations and explanations for the difference between Rexroth proportional valves and Rexroth servo valves, which is the main reason why most people do not understand the difference between the two.
|
|
The working principle of the Rexroth vane pump PV7 series
The working principle of Rexroth vane pump PV7 series: Rexroth vane pump PV7 series is a pump in which the blades in the rotor groove are in contact with the pump casing (stator ring) to press the suction liquid from the oil inlet side to the oil discharge side. Because there are two kinds of vane pumps in history, according to the different types of pumps, a) specifically refers to the positive displacement pump ...
|
|
Rexroth A10VO series variable piston pump structure description
A10VO series variable piston pump is one of Rexroth variable piston pumps, A10VO series is Rexroth medium pressure series swash plate axial piston pump, nominal pressure 280bar, used in open hydraulic circuits, the pump is very widely used, is used in various fields, including but not limited to...
|
|
Bosch Rexroth becomes a new partner of NEVONEX
· Bosch Rexroth Telematics Units (RCUs) help expand the digital ecosystem in agriculture
· The RCU can also be used as the basis for the manufacturer's own telematics solution
After partnering with Bosch Rexroth, NEVO, a manufacturer-independent provider of digital services ecosystem for agriculture ...
|
|
Rexroth solenoid valve model letter the meaning of each representative
EW stands for Exchange
EG stands for Direct Current
The meaning of each letter of Rexroth solenoid valve:
For example, 4WE6E6X/EG24N9K4
4→ 4-way (there are also 3-way) 4-way ports
6→ is 6
E→ functional symbols (also C, D, E, EA...)
|
|
Where does the daily maintenance of Rexroth hydraulic pump start?
1. Maintain a proper oil temperature
The working temperature of the hydraulic system is generally controlled between 30 and 80 °C (dangerous temperature ≥ 100 °C). Too high oil temperature in the hydraulic system will lead to: the viscosity of the oil will decrease, which will easily cause leakage and reduce efficiency; The strength of the lubricating oil film decreases, accelerating the mechanical ...
|
|
Applicability of Rexroth solenoid valves
1. Characteristics of the medium
1) Different varieties of solenoid valves are selected for gas, liquid or mixed state;
2) The medium temperature is different for products of different specifications, otherwise the coil will burn off, the seal will age, and the life of the product will be seriously affected;
3) The viscosity of the medium, usually below 50cSt. If...
|
|
Rexroth Hydraulic Pumps – How Does a Hydraulic Pump Work?
In modern construction machinery, basically inseparable from hydraulic working devices, even if the main working devices do not use hydraulic equipment, usually need hydraulic systems to achieve some auxiliary work, hydraulic pressure is so important, and our life and work is very close.
Image
But...
|
|
Rexroth's automation toolkit ctrlX AUTOMATION technology helps the food packaging industry
Machine builder ILLIG makes the ever-changing food packaging industry more flexible and forward-looking with the openness of the Bosch Rexroth Automation Toolkit ctrlX AUTOMATION technology.
Debut at Interpack 2023: the modular ILLIG XLU complete series ...
|
|
The purpose of using Rexroth proportional valves or servo valves
The purpose of using Rexroth Rexroth proportional valve or servo valve is: to achieve throttling control of the flow rate in an electronic control way (of course, pressure control can also be achieved after structural changes), since it is throttling control, there must be energy loss, servo valve is different from other valves, its ...
|
|
Rexroth pressure reducing valve fault phenomenon and elimination method
Rexroth Pressure Reducing Valve Failure Analysis:
1. Air is mixed into the oil
2. The damping hole is sometimes clogged
3. The roundness of the hole between the slide valve and the valve body exceeds the regulations, so that the valve is stuck
4. The spring is deformed or stuck in the spool valve, making it difficult for the spool to move or the spring is too soft 5.
|
|
Rexroth Hydraulic Pumps - What are the hazards of hydraulic pumps entering the air?
First, the rigidity of the hydraulic oil decreases sharply, resulting in the slower response of the hydraulic system and the reduction of efficiency, resulting in crawling and vibration of the actuator.
Second, air bubbles will cause oil film to be unable to form between moving parts, resulting in poor lubrication and aggravating the wear of hydraulic components.
The third is in the air ...
|
|
The first flushing step of the hydraulic system of the Rexroth Rexroth hydraulic pump
First wash. The first cleaning of the hydraulic system of the Rexroth Rexroth hydraulic pump is carried out after the pre-installation (trial assembly of the pipes) and the dismantling of the entire pipeline.
The first cleaning should ensure that a large number of metal burrs and powders, sand dust, ...
|
|
Rexroth: Intelligent linear robots for productivity
The easy-to-set up, highly integrated mechatronic subsystem provides a more efficient engineering handling solution. With the new Cartesian multi-axis system, Bosch Rexroth linear drive technology offers you a valuable competitive advantage.
The handling robot, which consists of linear axes, flows through the entire value ...
|
|
Rexroth inverter fault handling and maintenance methods
Minor and heavy faults of Rexroth inverters:
1. Minor faults include: inverter over-temperature alarm, cabinet over-temperature alarm, cabinet door opening, unit bypass, etc. The system does not remember the fault of the light, only the fault indication, and the alarm will be automatically eliminated after the fault disappears. During the operation of the inverter, if ...
|