The common reason why the touch screen and the PLC cannot communicate - Hitech

Create Date: 2024-8-30 12:03:23|Source: Hitec/HITECH

1. Whether to select the correct communication protocol (Modbus, PROFIBUS, CANopen, EtherCAT)

2. Whether the communication cable is OK (RS232 RXD TXD GND RS485 A+ B- CANopen CAN_L CAN_H CAN_GND EtherCAT cable) 3. Whether the communication parameters are correct (station number, baud rate, check digit) CAN communication requires terminal resistor 4. Whether there is a disturbance

The program can identify the failure of the communication between the touch screen and the PLC

The general method is to use heartbeat detection, say a bool, the HMI fixed frequency will set the point in place, and the PLC will reset it after receiving the point as an ON signal. If the signal of ON is not received within a period of time, such as 5 seconds, the communication is considered to be suspended.

The PLC transmits the memory clock byte to the screen, and the screen uses a script to assign the value of this byte to the address in another PLC, and then the PLC determines whether the two scanning cycles of the returned byte are the same, and if so, it is clarified that the communication is suspended.

                               The common reason why the touch screen and the PLC cannot communicate - Hitech

For example, the process is as follows:

1. Set up DB1 data block in PLC, and set up two switching quantities in it: "PLC second switch" and "man-machine echo switch";

2. Connect these two variables in the human-machine variable;

3. Add "inverted" to the attribute - thing - value change of the man-machine "PLC second switch" variable, so that the "man-machine echo switch" variable changes with the change of "PLC second switch";

4. Program in the PLC program block, let the "PLC second switch" reverse every 0.5 seconds, and then use the TON delay command to make the "man-machine echo switch" output within 1 second without action The human-machine communication fails, because the "human-machine echo switch" will no longer change after the human-machine communication is abnormal.

More on that
Hitec touch screen new and old models replacement selection Hitec touch screen new and old models replacement selection

Hitec touch screen selection: 10.4" Series: PWS6A00T-N (True Color Network), PWS6A00T-P (True Color Enhanced), PWS6A00T-S (Color Basic) 7.5" Series: PWS6800C-N ...

The driving principle of a capacitive touch screen The driving principle of a capacitive touch screen

1. Projective capacitive contacts Although the basic structure and operating principle of the projection capacitive contact screen is the same as that of the four-wire impedance film, the projection capacitive impedance film does not pass through the contact field, but captures the change of capacitance between the electrodes. Generally speaking, when using the form of capacitive sensor, it can almost ...

Four-wire resistive touch screen troubleshooting – Hitech Four-wire resistive touch screen troubleshooting – Hitech

Imprecise screen orientation: can be positioned from scratch by the driver software. Contact orientation and screen cursor inversion: When the device touches the screen, the orientation of the screen is inverted, please adjust the contact screen orientation according to the guidelines of the right-hand orientation. ...

Hitec touch screen response failure analysis Hitec touch screen response failure analysis

First, the touch screen response time is very long Problem phenomenon: A contact screen, touch the monitor screen with your fingers, and it takes a long time to react. Problem profiling and processing This could be a touch screen with moving water droplets, just wipe it with a dry, soft cloth ...

Categories and Advantages and Disadvantages of Resistive Touch - Hitech Categories and Advantages and Disadvantages of Resistive Touch - Hitech

Resistance contact is divided into four-wire resistance and five-wire resistance contact, the simple difference is four wires and five wires in the functional area. A constant voltage of 5V is added to each layer of the two-layer transparent metal layer with four-wire resistance analogue technology: ...

Touch screen dimming fault analysis and treatment method - Hitec Touch screen dimming fault analysis and treatment method - Hitec

Touch screen dimming fault phenomenon: The touch screen has darkened and the colors are not displayed normally, but there is no problem with the operation. Fault profiling : The reason for this state of affairs may be that in the 2000s ...

Industrial touch screen touch solves the problem of unresponsiveness Industrial touch screen touch solves the problem of unresponsiveness

Many people have encountered industrial contact screen contact no response, no matter how we point to the industrial contact screen is not responding, at this time many people don't know what to do, today let's take a look at what to do when encountering industrial contact screen contact no response. ...

Common faults of Hitec touch screens Common faults of Hitec touch screens

1. Observe the signal indicator of Hitec touch screen, the light flashes regularly under normal circumstances, about once per second, when touching the screen, the signal light is always on, and after stopping the touch, the signal light resumes flashing. 2. If the signal light is not touched, it is still at ...

The relationship between human-computer interaction and human-computer interface design - Hitec The relationship between human-computer interaction and human-computer interface design - Hitec

1. Human-computer interaction and human-computer interaction (English: Human–Computer Interaction or Human–MachineInteraction, referred to as HCI or HMI) is a study of the interaction relationship between the system and the user. ...

Capacitive touch screen parameters Capacitive touch screen parameters

1. Reporting rate: too fast, the CPU can not respond in time, which may cause drops, and the line is easy to break 2. Accuracy: 99% accuracy 3. Sensitivity: less than two ounces of force can be sensitized, less than 3ms fast response 4. Resolution: with the X, Y axis ...

Industrial touch panel PC for dismantling and screen replacement - Hitec Industrial touch panel PC for dismantling and screen replacement - Hitec

In the use of industrial tablet computers, in many cases, there will always be some accidental situations, and it is likely that it will be necessary to disassemble and replace the screen before it can be processed. 1. Strong ...

The defect of the capacitive touch screen - Hitec The defect of the capacitive touch screen - Hitec

The light transmittance and clarity of the capacitive contact screen are better than those of the four-wire resistive screen, and of course it cannot be compared with the external acoustic wave screen and the five-wire resistive screen. The capacitive screen is severely reflective, and the four-layer composite contact screen of the capacitive skill has a strong impact on each wavelength ...

Anti-interference method of PLC and touch screen - Hitech Anti-interference method of PLC and touch screen - Hitech

To improve the anti-disturbance ability of the PLC system, we can select products with higher anti-disturbance ability when carrying out the anti-disturbance planning of detailed engineering, and adopt methods such as pressing the disturbance source, blocking or attenuating the propagation path of electromagnetic disturbance, and using software means to improve the anti-disturbance of the equipment and system.

Capacitive touch screen cable fault solved Capacitive touch screen cable fault solved

Capacitive touch screen skills use human current to detect jobs. The capacitive touch screen is a 4-layer composite glass screen. The inner and outer surface of the glass screen and the interlayer are coated with a layer of ITO, and the outermost layer is a thin protective layer of silica glass. Sandwich ITO coating for the working surface, 4 edges guiding 4 electrodes, internal ITO for ...

HMI Faults and Solutions for Human-Machine Interfaces - Hitec HMI Faults and Solutions for Human-Machine Interfaces - Hitec

Human Machine Interaction (HMI), also known as user interface or user interface, is a preface and dialogue interface for transmitting and communicating information between humans and computers, and is an important part of computer systems. It is the interaction and information between the system and the user ...

The reason for choosing a vision system is Hitech The reason for choosing a vision system is Hitech

The visual system is a rising star in industrial automation, and the demand for work efficiency in modern industrial automation is constantly improving, and the traditional form of manual detection has been unable to meet the needs of production. The presentation of the machine vision system is a good replacement for the cumbersome traditional manual labor, which is suitable for ...

Hitec touch screen daily simple maintenance tips Hitec touch screen daily simple maintenance tips

1. In the daily use of the equipment, try to prevent frequent power off and off, and sudden power failure during operation will cause certain damage to electronic components and hard disk errors; In terms of power supply, keep operating in a stable voltage environment, too low voltage, too high voltage will affect the function of the equipment, and will also ...

Introduction to human-machine interface technology - Hitec Introduction to human-machine interface technology - Hitec

Human-computer interface, the real sense of human-computer interaction method is that people will get rid of any form of interactive interface, the method of entering information is becoming more and more simple, casual, capricious, with the help of artificial intelligence and big data, you can be very intuitive, direct, comprehensive capture of human needs, and...

Hitec touch screen calibration method Hitec touch screen calibration method

(1) After the terminal is turned on, find out whether each calibration teaching file is not clicked in the execution step (2) If it exists, perform the step (4); (2) After the boot is finished, the active high-motion is the quasi-program, prompting the user to calibrate the touch screen, after the calibration is completed, the touch screen driver ...

Key points for the use of industrial control touch screen all-in-one machine - Hitec Key points for the use of industrial control touch screen all-in-one machine - Hitec

Storage humidity between 10%-90% Temperature -20°C-60°C If the ambient conditions exceed or approach the critical value, condensation will occur inside the display. The power transformer and other coils inside are also prone to leakage when wet, and may even cause a short circuit in the wiring. If you find that the obvious ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top