Hardware failure of the switch:
(1) Power failure:
The power supply is damaged or the fan stops due to unstable external power supply, aging power lines, lightning strikes, etc., and the fan cannot work properly. It is not uncommon for other parts of the aircraft to be damaged due to the power supply.
If the POWER indicator on the panel is green, it means normal; If the light is off, the switch is not powered properly. This kind of problem is easy to find, easy to solve, and easy to prevent.
For this kind of fault, the first thing to do is to do a good job of external power supply, generally by introducing independent power lines to provide independent power supply, and adding voltage regulators to avoid instantaneous high or low voltage phenomenon. If conditions permit, you can add UPS (uninterruptible power supply) to ensure the normal power supply of the switch, some UPS provides voltage stabilization function, and some do not, pay attention to the selection. Set up professional lightning protection measures in the equipment room to avoid lightning damage to the switch. Nowadays, there are many professional companies that do lightning protection engineering, which can be considered when implementing network cabling.
(2) Port failure:
This is a common hardware failure, whether it is an S fiber port or an RJ-45 port of a twisted pair, you must be careful when plugging and unplugging the connector. If you accidentally stain the fiber optic plug, it may cause the fiber optic port to be contaminated and unable to communicate properly. We often see a lot of people who like live plug-in connectors, which is theoretically possible, but this also inadvertently increases the failure rate of the port. Carelessness during handling can also lead to physical damage to the port. If the purchased crystal head is too large, it is easy to damage the port when plugged into the switch. In addition, if a section of twisted pair cable connected to a port is exposed to the outdoors, if the cable is struck by lightning, it can cause the connected switch port to be broken, or cause even more unforeseen damage.
In most cases, a port fault is when one or more ports are damaged. Therefore, after eliminating the fault of the computer connected to the port, you can determine whether it is damaged by replacing the connected port. In case of such failures, you can clean the port with an alcohol cotton ball after the power is turned off. If the port is indeed damaged, the only way to do it is to replace it.
(3) Module failure:
A switch is composed of many modules, such as stacking modules, management modules (also called control modules), and expansion modules. There is a small chance that these modules will fail, but if they do occur, they can suffer huge financial losses. Such failures can occur if the module is accidentally plugged and unplugged, or if the switch is bumped while transporting the switch, or if the power supply is unstable.
Of course, the three modules mentioned above have external interfaces, which are relatively easy to identify, and some can also identify faults through the indicator lights on the modules. For example, a stacked module has a flat trapezoidal port, or some switches have a USB-like interface. There is a CONSOLE port on the management module, which is used to establish a connection with the network management computer for easy management. If the expansion module S is connected to optical fiber, there will be a pair of optical fiber interfaces.
When troubleshooting such faults, first ensure that the power supply of the switch and module is normal, then check whether each module is plugged in the correct position, and then check whether the cable connecting the module is normal. When connecting the management module, it is also necessary to consider whether it adopts the specified connection rate, whether it has parity, whether there is data flow control and other factors. When connecting an expansion module, it is necessary to check whether the communication mode is matched, e.g. whether to use full-duplex mode or half-duplex mode. Of course, if it is confirmed that the module is faulty, there is only one way to solve it, and that is to contact the supplier immediately to replace it.
(4) Backplane failure:
The individual modules of the switch are plugged into the backplane. If the environment is humid, the circuit board is short-circuited due to moisture, or the components are damaged due to high temperatures, lightning strikes and other factors, the circuit board will not work properly. For example, the heat dissipation performance is not good or the ambient temperature is too high, which causes the temperature in the machine to rise, which means that the components will burn out.
In the case of normal power supply of external power supply, if the internal modules of the switch are not working normally, it may be that the backplane is broken, even if the electrical maintenance engineer has no choice but to replace the backplane.
(5) Cable failure:
In fact, theoretically speaking, this kind of fault does not belong to the fault of the switch itself, but in actual use, cable faults often cause the switch system or port to fail to work normally, so this kind of fault is also classified as a switch hardware fault. For example, the connector is not tightly plugged in, the sequence of cables is wrong or not standardized, the cable connection should be crossed but the straight connection is used, the two optical fibers in the optical cable are staggered, and the wrong line connection leads to network loops.
Judging from the above hardware failures, the poor environment of the computer room can easily lead to various hardware failures, so when we build the computer room, we must first do a good job in the construction of lightning protection and grounding, power supply, indoor temperature, indoor humidity, anti-electromagnetic interference, anti-static and other environments, so as to provide a good environment for the normal operation of network equipment.
|
More on that
|
Advantech Motherboards – 5 Practical Ways to Choose an IPC Motherboard
1. Look at the chipset
The chipset determines the positioning of the motherboard, and almost all the functions of the motherboard. It should be noted that motherboards with different chipsets do not affect the functionality of the CPU, but affect the functionality of other components. Intel motherboard chipsets come in four grades, which are X/Z...
|
|
Advantech Industrial Panel PC - Introduction to the functional characteristics of industrial panel PC
Different from general commercial computers, the industrial tablet PC series products have the characteristics of ruggedness, shockproof, moisture-proof, dust-proof, high-temperature resistant multi-slot, and easy expansion according to the environmental characteristics. It is the best platform for a variety of industrial control, traffic control, environmental control and other applications in the field of automation.
|
|
Advantech Smart Display helps build a green factory
In recent years, global climate change has been rapid, and green factories, as an important part of the green supply chain, have become the standard actively established by the global supply chain. From the plant to the production line, how to achieve "green planning" has become the focus of automation manufacturers' thinking. Advantech's display and e-paper solutions ...
|
|
Advantech IPC - What are the differences between embedded IPC and traditional IPC?
In recent years, embedded industrial computers have matured rapidly, and the application range is becoming more and more extensive, to a certain extent, in some fields, traditional industrial computers have been replaced by new embedded computers. At present, the number of applications of embedded industrial computers far exceeds that of various traditional industrial computers, and the manufacturing industry ...
|
|
The functional characteristics of Advantech switches are introduced in detail
Features of Advantech's EKI-2525 Industrial Switch:
Provides 5/8 adaptive Fast Ethernet ports
Support 10/100Mbps self-adaptation
Provides broadcast storm protection
Compact and supports DIN rail mounting/wall mounting
Support 12-48VDC redundancy ...
|
|
Advantech Launches Smart Edge All-in-One Appliance for Zero-Carbon Factories
Advantech has launched the "Zero Carbon Factory Intelligent Edge All-in-One Machine" software and hardware integration lightweight package to help enterprises achieve "zero carbon" management, help customers achieve energy consumption transparency and reduce energy consumption costs with a small investment, and can set KPI tracking and management to prevent equipment inefficiency.
|
|
Advantech Releases Industrial-Grade 112-Layer BiCS5 3D NAND SSD
Advantech is pleased to announce the adoption of KIOXIA 112-layer flash BiCS5 in multiple series and form factors. The new SQFlash BiCS5 3D TLC supports up to 8TB of image/video/massive data manipulation and storage needs. In addition, SQFlash BiCS5 broadens the local operating temperature for NAND chips.
|
|
Advantech switches – the networking mode of industrial Ethernet switches
Industrial Ethernet switches are specifically designed to meet the needs of flexible industrial applications, providing a cost-effective Industrial Ethernet communication solution. The networking method focuses more on loop design. There is a distinction between single-loop and multi-loop loops, and there are also differences between STP and RSTP foundations.
|
|
Advantech smart in-vehicle display and vehicle monitoring system
Advantech smart in-vehicle display and vehicle monitoring system
Advantech's mobile data terminals provide vehicle monitoring and fleet management application solutions to help fleet owners track trucks' operational resources and manage truck scheduling more effectively. Advantech TREK ...
|
|
How to set up USB flash drive boot on Advantech server?
Preparation
1. Prepare the USB flash drive.
2. Insert the USB flash drive into the industrial computer.
3. Restart the industrial computer and press del to enter the CMOS settings.
Second, modify the settings
1. Find USB Con in the Advanced menu...
|
|
Advantech Tablet - What is the difference between an industrial tablet PC and an ordinary computer?
First, the internal components used are different. Due to the complex environment, industrial tablet PCs have higher requirements for products, such as stability, anti-interference, waterproof, shockproof and other functions; Ordinary tablets are mostly used in the home environment, pursuing timeliness, taking market positioning as the standard, and the internal components only need to ...
|
|
Advantech IPC - Common Faults and Solutions of IPC (1-5)
1. Turn on the computer and the computer does not respond
1. Check whether the industrial computer is connected correctly and whether the power socket has electricity;
2. Check the power supply of the industrial computer, whether the power supply fan can work normally after turning on, and whether the monitor is connected to the host correctly;
3. If ...
|
|
Advantech IPC - What should I pay attention to when purchasing an IPC?
1. Environmental requirements: The reason why the industrial computer is different from the ordinary civil computer is that it can be used in harsh environments, such as ultra-high or ultra-low temperature, high dust, high vibration and other occasions, so when choosing an industrial computer, it is necessary to carefully check whether its parameters can meet the requirements of your application environment.
|
|
Advantech motherboard: How to set up hard disk boot
1. Enter BIOS: Turn on or restart the computer, and press the DEL key on the keyboard when the boot screen appears to enter the BIOS setting table.
2. Once in the BIOS settings, use the arrow keys on your keyboard to move to the Advanced menu option and find SATA Config in it...
|
|
Advantech Switches – Introduction to the functions of network switches
The main functions of the switch include physical addressing, network topology, error checking, frame sequence, and flow control. At present, the switch also has some new functions, such as support for VLANs (virtual local area networks), support for link aggregation, and even firewall functions.
...
|
|
Advantech Industrial Motherboard - Classification and introduction of IPC motherboards
1. ATX motherboard: ATX is a motherboard specification formulated by Intel Corporation in 1995, which is the first major change in the design of computer cases and motherboards in many years. The more common ATX motherboard, large rectangle, generally 7 expansion slots, the size is about 305x244mm. ATX boards are still ...
|
|
Advantech's 10-inch IPC tablet PC is recommended
MIT-W101
The 10-inch industrial tablet PC is equipped with a new generation of Intel ® processors
Intel ® Celeron ®N2930 quad-core processor
Support Windows 8, Windows 10 operating system
10.1" WXGA, Projected Capacitive Multi-touch Display ...
|
|
Advantech highlighted AI cooling systems at the IoT Co-creation Summit
Suzhou, China, November 1, 2018 – Advantech today announced that it will be a leading dynamic cooling management system at the Advantech IoT Co-creation Summit held in Suzhou, China, November 1-2, as an early success story of its IoT co-creation project.
|
|
Advantech - Why are SSDs more power-efficient than HDDs?
At present, the mainstream hard disks are mainly divided into: HDD (Hard Disk Drive), which is a mechanical hard disk, and SSD (Solid Disk Drive), which is a solid state drive. In terms of power consumption, SSDs have better performance than HDDs, so what causes them?
01 Solid ...
|
|
Advantech's edge computing is among the top 20 companies
Edge Measurement Street announced the overall list of "2020 China's Top 20 Edge Computing Companies", and Advantech High-tech was selected for the overall list with its years of deep cultivation in the edge measurement industry, independent innovation and outstanding brand advantages.
With the advent of 5G, the Internet of Things ...
|
|