Description: The Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341624 that leverages the power of a field-proven, United Kingdom-designed Rosemount quad string meter (OIML R137 1&2 accuracy class 0.5) combined with a second reflective verification flow meter to provide outstanding custody transfer accuracy and reliability.
Features:
Highly sensitive, vertical monitoring channels for real-time detection of liquid traces/remnants along the bottom of the pipe
Patented sensor synchronization prevents interference and noise and speeds up flow disturbance detection
By working together with the chord and reflection channels, common pattern errors are avoided
Reduce measurement uncertainty by alerting for pipe wall build-up, liquids, clogging, and gas quality degradation
The 3D view of the flow profile shows swirls, cross-currents, asymmetrics, and turbulence to accelerate problem solving
Human error is reduced by automatic calculation of the AGA 8 compression coefficient and the AGA 10 sound velocity
Adopt the new Type 4 CPU module (with up to 6 frequency or digital outputs) to increase inputs/outputs
Product parameters
Precision:
Four-channel flow meter: ±0.05% of reading over the entire calibration range
Two-channel flow meter: ±0.2% of reading when calibrated (±1.5% of actual volume without calibration)
Repeatability:
Quad Flow Meter: ±0.05% of reading at 1.5 to 30.5 m/s (5 to 100 ft/s)
Two-channel flow meter: ±0.1% of reading at 1.5 to 30.5 m/s (5 to 100 ft/s)
Speed: Rated flow rates up to 30m/s (100fps) and up to and beyond 38m/s (125fps) for some calibers
Operating temperature range:
T-21 Sensor: -20°C to +100°C (-4°F to +212°F)
T-22 Sensor: -50°C to +100°C (-58°F to +212°F)
Operating pressure range:
T-21/T-22 sensor: 689 to 27,579kPag (100 to 4,000 psig)
T-21/T-22 Sensors: 345kPag (50psig) minimum operating pressure at Qmax reduction (see product data sheet)
Material: carbon steel and stainless steel
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the USM341810 products of Rosemount/Rosemount Ultrasonic Flow Meter, if you are interested in Rosemount/Rosemount Ultrasonic Flow Meter, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount Flanged Vortex Flow Meter 8800DD100
Description: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DD100 features redundant, independent sensors and electronics to help avoid false starts. Suitable for safety interlock systems and related applications.
Features:
The isolated sensor design allows for a process without destroying the process code.
|
|
Rosemount/Rosemount 4+2 Dual-Configuration Gas Ultrasonic Flowmeter 3416
Introduction: The Rosemount/Rosemount 4+2 Dual-Configuration Gas Ultrasonic Flowmeter 3416, Rosemount 3416 4+2 Ultrasonic Flowmeter combines a proven Rosemount four-channel British Gas string meter (validated to OIML R137 1&2 accuracy class 0.5) and ...
|
|
Rosemount/Rosemount Clamp Temperature Sensor 0085 Class A Sensor
Description: The Rosemount/Rosemount Clamp Temperature Sensor 0085 is available in a variety of clamp sizes and materials and can be mounted in any position to provide a surface temperature measurement solution that can accommodate a wide range of temperatures. This platinum resistance resistance (RTD) sensor is available with silver or ...
|
|
Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8705120 15-900mm diameter
Description: The Rosemount/Rosemount electromagnetic flowmeter sensor is 8705120, with an all-welded construction that provides an airtight port for moisture and contaminant protection, while the junction box is removable and replaceable for easy field service.
Features:
For maximum protection, ...
|
|
Rosemount/Rosemount pH/ORP Sensor 396PVP
Introduction: Rosemount/Rosemount pH/ORP Sensor 396PVP, The Rosemount Model 396PVP sensor has been specifically designed to improve the effectiveness of harsh, dirty, and abrasive applications with large amounts of suspended solids (e.g., lime slurry, wastewater treatment, paper machine headbox, and dyeing, etc.).
|
|
Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707100 consumes up to 300W
Description: The Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707100 provides enhanced signal strength along with advanced signal processing and superior filtering technology for flow metering stability in the most difficult, noisy slurry applications.
Features:
...
|
|
The Rosemount/Rosemount Low Temperature Sensor 614 has an accuracy of ± 0.02 °C
Introduction: The Rosemount/Rosemount Cryogenic Point Temperature Sensor 614 is designed for temperature measurement in cryogenic and refrigerated storage tanks. These point temperature elements are routed using mineral-insulated, flexible steel cables to measure the internal temperature of a fully loaded tank during cooling and to detect tank isolation during cooling.
|
|
Rosemount Hydrofluoric Acid Resistant pH Sensor 372 Range: 0—12pH
Description: The Rosemount/Rosemount Hydrofluoric Acid Resistant pH Sensor 372 uses a special glass formulation that greatly reduces the rate of HF corrosion, making it more cost-effective to measure HF solutions containing up to 1% (10,000 ppm).
Features:
After on-site inspection...
|
|
Rosemount/Rosemount In-Line Oxygen Analyzer 6888A Ambient temperature -40 to 70°C
Description: The Rosemount/Rosemount In-Line Oxygen Analyzer 6888A continuously and accurately measures the amount of oxygen in the flue gas of any combustion process. Accurate measurement of residual oxygen is critical to combustion reactions, reducing energy costs, improving safety, and reducing emissions. Rugged oxygen ...
|
|
Rosemount/Rosemount Retractable pH/ORP Sensor 398R
Introduction: The Rosemount/Rosemount Retractable pH/ORP Sensor 398R, the Rosemount 398R, with its Tefzel™ and titanium chemically resistant construction and patented TUpH™ reference junction, make it an ideal sensor for measuring the pH of demanding process liquids. ...
|
|
Rosemount/Rosemount Pressure Sensor MAS2600 Weight: 0.3kg
Introduction: The Rosemount/Rosemount pressure sensor MAS2600 uses MAS2600 pressure sensors to obtain accurate level and wind data for marine storage tanks. The sensor is designed to be mounted inside or outside the tank roof and sides, providing the flexibility to meet your needs ...
|
|
Rosemount/Rosemount High Static Differential Pressure Transmitter 3051S
Introduction: Rosemount/Rosemount 3051S High Differential Pressure Transmitter, the Rosemount 3051S High Differential Pressure Transmitter is engineered to withstand static pressures up to 15000 psi (1034 bar) and is designed with a compact SuperModule™ for harsh production ...
|
|
Rosemount Vibrating Tuning Fork Level Switch 2521 Working pressure 16 bar
Introduction: Rosemount/Rosemount Vibrating Fork Level Switch 2521, Rosemount 2521 Vibrating Tuning Fork Level Switch is suitable for applications that require high sensitivity, such as the measurement of fine particles and powdery media in storage and process vessels. It is a highly sensitive and easy-to-use ...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381424 Pressure range 0 to 155 Bar
Description: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381424, a new custody transfer meter with excellent linearity over the flow range to further reduce product loss and unidentified loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381412
Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381412, a new custody transfer meter with excellent linearity over the flow range to further reduce product loss and unspecified loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Vortex Flow Meter 8800DR010 Turndown ratio 38:01:00
Description: The Rosemount/Rosemount Vortex Flow Meter 8800DR010, an integrated downsized gauge accurately measures lower flow rates and maintains the same surface spacing as a standard flanged vortex gauge.
Features:
Intelligent reducer design improves low flow measurement ...
|
|
Rosemount/Rosemount Corrosion and Erosion Monitoring System Permasense ET410
Introduction: The Permasense ET410, a unique ultrasonic sensor that continuously measures pipe thickness and provides real-time insight into corrosion and erosion trends, is the Permasense ET410 corrosion and erosion monitoring system. The ET410 sensor system is a non-intrusive, battery-powered, fast...
|
|
Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW040
Description: The Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW040 provides a cost-effective, lightweight alternative to flanged vortex flow meters. The compact, space-saving design is versatile and can be installed in any location
Product Features ...
|
|
Rosemount/Rosemount General Purpose pH/ORP Sensor 389
Introduction: Rosemount/Rosemount Universal pH/ORP Sensor 389, the Rosemount 389 sensor uses a molded Tefzel™ body and Viton™ O-rings to make each sensor extremely difficult to damage and highly resistant to chemicals. The complete package eliminates the need for additional pH ...
|
|
Rosemount/Rosemount Level Switch 2110 Operating Pressure: -3.62—1450 psi
Introduction: Rosemount/Rosemount Level Switch 2110, The Rosemount 2110 Level Switch provides reliable level detection and reduces the need for maintenance for measurements in tight spaces and pipelines. Level applications and basic spill protection can be installed simply and quickly. Compliance with hygienic certifications, expanding the ...
|
|