Introduction: The Rosemount/Rosemount Ultrasonic Gas Leak Detector Incus, Incus is an advanced ultrasonic gas leak detection system equipped with four ultra-sensitive sound sensors that continuously monitor the ultrasonic waves generated by the release of pressurized gases over a wide area. Ideal for monitoring well-ventilated outdoor environments, Incus ultrasonic detectors are designed to withstand extreme conditions and are not affected by inclement weather, wind direction, leak direction, and gas dilution or delamination.
Features:
Immediate response to all gas leaks (toxic, flammable or inert).
No calibration is required
Quad sensor head for particularly wide overall monitoring range: 2 to 40 m (7 to 130 ft)
Each sensor is completely free of moving parts, will not age, will not drift, and will never need to be replaced under normal operating conditions
Operates in extreme temperatures: -40°C to 85°C (-40°F to 185°F)
Automatic electronic self-test for fail-safe operation
4–20mA analog or stepped "multipoint" RS-485 digital interface, and HART™ communication protocol
Worldwide Hazardous Location Approvals: IECEx, ATEX, c FM US, EAC, KOSHA, INMETRO, ABS, DNV
Innovative mapping tools assist in the optimization of the scope of target risks
Programmable time delays filter out intermittent unwanted warning sources
Product parameters
Installation: AISI 316 stainless steel (included)
Power supply: 15 - 30Vdc (24Vdc)
6W - Standard Operation
Weight: 18kg (40lb)
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces Rosemount/Rosemount Ultrasonic Gas Leak Detector Incus products, if you are interested in Rosemount/Rosemount Ultrasonic Gas Leak Detector, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
The Rosemount/Rosemount Temperature Transmitter 644 outputs 4-20mA
Introduction: Rosemount/Rosemount Temperature Transmitter 644, the Rosemount 644 temperature transmitter is versatile and available using HART®, FOUNDATION™ fieldbus, or PROFIBUS® protocols, with top, field, or rail mounting styles and a variety of enclosure options. Pass...
|
|
Rosemount/Rosemount Clamp-on Electromagnetic Flowmeter Sensor 8711005 40:1 turndown ratio
Description: The Rosemount/Rosemount clip-on electromagnetic flowmeter sensor 8711005 and the flangeless design provides a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, dimensions and ...
|
|
The Rosemount/Rosemount Chip Electromagnetic Flowmeter Sensor 8711 has a turndown ratio of 13:1
Introduction: The Rosemount/Rosemount Chip Electromagnetic Flowmeter Sensor 8711 is designed to be flangless, economical, compact, and lightweight, and can replace flanged electromagnetic flowmeters. The product is available in a wide range of durable lining and electrode materials, from highly corrosive liquids to fibrous slurries ...
|
|
The Rosemount/Rosemount Low Flow Conductivity Sensor 404 cable is 3.1m in standard length
Introduction: The Rosemount/Rosemount Low Flow Conductivity Sensor 404 can be used to measure the conductivity of clean water. The sensors and flow cells are combined into a separate package. Because the retention volume of the flow cell is small, it reacts more quickly to sudden changes in conductivity and temperature. 404 Sensing ...
|
|
Rosemount/Rosemount Toroidal Conductivity Sensor 228 stainless steel
Description: The Rosemount/Rosemount Toroidal Conductivity Sensor 228 performs well in high conductivity liquids up to 2S/cm (2,000,000uS/cm). These sensors can still function in dirty and corrosive environments where metal electrode sensors can fail. Reliable...
|
|
Rosemount/Rosemount Field Communication Unit 2460 Power Supply 24-48VDC
Introduction: Rosemount/Rosemount Field Communication Unit 2460, the Rosemount 2460 Field Communication Unit transmits real-time tank metering data from field devices to Rosemount TankMaster inventory management software and/or host/DCS systems. There are eight configurable ends.
|
|
Rosemount Hydrofluoric Acid Resistant pH Sensor 372 Range: 0—12pH
Description: The Rosemount/Rosemount Hydrofluoric Acid Resistant pH Sensor 372 uses a special glass formulation that greatly reduces the rate of HF corrosion, making it more cost-effective to measure HF solutions containing up to 1% (10,000 ppm).
Features:
After on-site inspection...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381424
Description: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381424, a new custody transfer meter with excellent linearity over the flow range to further reduce product loss and unidentified loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341212
Introduction: Rosemount/Rosemount primary sonic gas ultrasonic flowmeters are USM341212 for non-legal-for-trade metering of natural gas, such as verification metering, pipeline balancing, storage measurement, production or moisture metering. Featuring Mark III electronics and two-channel measurement redundancy.
...
|
|
Rosemount/Rosemount Wireless Integrated Orifice Flowmeter 3051CFP tubing sizes range from 15 to 40mm
Description: The Rosemount/Rosemount Wireless All-in-One Orifice Flow Meter 3051CFP, with the Rosemount 3051CFP Wireless All-in-One Orifice Flow Meter, there are no wiring costs and industry-leading accurate flow measurement through the WirelessHART® protocol. By Ann ...
|
|
The Rosemount/Rosemount Gauge and Absolute-Pressure Transponder 2088 has a 50:1 higher turndown ratio
Introduction: Rosemount/Rosemount Gauge & Absolute Pressure Transmitter 2088, with the Rosemount 2088 Gauge & Absolute Pressure Transmitter, you can get the job done on time with a quick and easy-to-install solution. The transmitter features a Field Operator Display Interface (LOI) that provides an easy-to-use ...
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF010 Turndown ratio 38:01:00
Description: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF010 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Thin Slice Vortex Flow Meter 8800DW010 Outputs 4-20mA
Description: The Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW010 provides a lightweight, cost-effective alternative to flanged vortex flow meters. The compact, space-saving design is versatile and can be installed in any location.
Products...
|
|
Rosemount/Rosemount High Temperature Oxygen Analyzer 5081FG
Introduction: The Rosemount/Rosemount HVO Analyzer 5081FG, Rosemount 5081FG Field HTC Transmitter provides continuous, accurate measurement of residual oxygen in flue gases from 550° to 1400°C combustion. The 5081FG is an explosion-proof and intrinsically safe circuit for ...
|
|
Rosemount/Rosemount 648 Wireless Temperature Transmitter Dual chamber enclosure
Description: The Rosemount 648 wireless temperature transmitter provides outstanding wireless accuracy and stability for process monitoring. This durable transmitter uses a dual-chamber housing for better reliability in the field. The transmitter works with Rosemount X-well™ technology and Rosemount 0085 ...
|
|
Rosemount/Rosemount Transmitter 702 Update time 1 second to 60 minutes
Introduction: The Rosemount/Rosemount Transmitter 702 Plunger in Place Detection Discrete Transmitter uses a plunger to improve the efficiency of natural gas well sites. The transmitter is used in conjunction with an existing plunger position sensor to detect a position event and send back a wireless signal.
Features:
Designed for ...
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF080 Turndown ratio 38:01:00
Introduction: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF080 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Optical Dissolved Oxygen System RDO resolution 0.01ppm
Introduction: The Rosemount/Rosemount Optical Dissolved Oxygen System RDO, RDO® Sensors & Analyzers designed for the determination of dissolved oxygen in water. It is ideal for wastewater aeration tanks and aeration ponds. The sensor can be calibrated according to standard test instruments or water-saturated air. Air calibration can be ...
|
|
The Rosemount/Rosemount Hygienic Pressure Transmitter 2051HT offers a turndown ratio of up to 50:1
Introduction: The Rosemount/Rosemount Hygienic Pressure Transmitter 2051HT provides a reliable solution for gauge and absolute pressure measurements in the life sciences and food and beverage industries. The transmitter features Emerson's reliable pressure sensor technology and industry-standard process connections ...
|
|
Rosemount/Rosemount Sensor 8721 Caliber 1/2-4 inch
Description: The Rosemount/Rosemount Sensor 8721 features a fully welded instrument body and is specifically designed for safe, hygienic and reliable performance in food, beverage and life sciences applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
|
|