1. The scale of the sensor:

(1) In normal use (static test or quasi-static test, the frequency of use is not high), the size of the sensor should be selected to consider the force value of the measurement, but also to consider the weight of the auxiliary tool (test fixture), etc., the general selection of the sensor scale is (measurement + tool) × 1.2-1.5 times.

(2) When used dynamically, the scale of the sensor is generally selected to be greater than 3-5 times of the measuring force.

(3) Considering that when the maximum output of the equipment (servo motor, cylinder output, etc.), it is necessary to consider the effect of the pulse on the sensor. As a result, the size of the sensor at the time of selection is more than twice that of an overshoot.

                              Range, accuracy and installation of load cells – ifm

2. Accuracy of the sensor:

(1) The accuracy of the sensor should be selected according to the requirements of the measurement system for the load cell.

(2) The induction accuracy of the sensor: &=(√(RL2+RR2+RH2+CP2))/4, the linearity of the sensor, hysteresis, repeatability, creep, sensitivity temperature affect the induction value, and the induction accuracy of the sensor is 2-3 times higher than the system accuracy.

(3) Sensor sensitivity S, determine the resolution of the sensor, and determine the system resolution.

3. Installation method:

(1) Fixing method: thread, plane, accessories and other fixing methods.

(2) Installation space: determine the scale requirements of the sensor: length, width, outer diameter, etc.

More on that
ifm products in the automotive industry ifm products in the automotive industry

For more than 30 years, ifm is a global group of companies that researches, manufactures and sells components and systems for the detection, control and processing of signals – from standard sensors to application-specific controllers. ...

The difference between ifm inductive and capacitive sensors The difference between ifm inductive and capacitive sensors

There are many different series under ifm sensors, including inductive and capacitive sensors. So what's the difference between the two sensors? ifm inductive sensors are essential in industrial use.

ifm takes you through level sensors ifm takes you through level sensors

How it works Static pressure measurement principle: when the liquid level sensor is put into a certain depth in the liquid to be measured, the pressure on the liquid surface of the sensor is formulated as: Ρ = ρ .g.H + Po formula: P: The pressure on the liquid surface of the transmitter ...

Fuel level sensors monitor the cause of the fuel level – ifm Fuel level sensors monitor the cause of the fuel level – ifm

The oil level sensor according to the resistance is mechanically connected to the float, and the float can rise or fall with the fuel level, and the resistance of the sensor changes as the float moves. The sensor used is part of the current balance circuit in the fuel gauge display circuit, which is generally used to drive ...

Grounding Considerations for Servo Drives – ifm Grounding Considerations for Servo Drives – ifm

1. The correct shield grounding point is at the reference potential inside the circuit, which depends on whether the noise source and receiver are grounded together, or may float. Second, it is necessary to ensure that the shield is grounded at the same point so that the ground power ...

The main feature of the wireless sensor network is the ifm sensor The main feature of the wireless sensor network is the ifm sensor

(1) Large-scale In order to obtain accurate information, many sensor nodes are usually arranged in the monitoring area, perhaps in the tens of thousands, or even more. The large-scale nature of the sensor network contains two implications: on the one hand, the sensor nodes are distributed in a large geographic area, such as in the original ...

Failure analysis of ifm gas sensors Failure analysis of ifm gas sensors

1. How long does it take for the gas sensor to be recalibrated after use: The length of the time distance between the initial calibration and recalibration depends on many factors, generally including the operating temperature, humidity, pressure, what kind of gas the sensor is exposed to, and the length of time it is exposed to the gas. But most of the ...

Precautions for the installation of high-frequency pressure sensors – ifm Precautions for the installation of high-frequency pressure sensors – ifm

The depth of the internal thread of the installation with the sensor should be greater than the length of the external thread of the sensor itself, so as to avoid the sensitive diaphragm of the sensor pushing to the bottom of the internal thread, so that the sensor is affected by stress. If the size of the internal thread has been ...

Wireless sensor problems and solutions – ifm Wireless sensor problems and solutions – ifm

1. After the wireless sensor device is installed, it appears to be beating or the number is inaccurate Reason: There is electromagnetic interference on the site, or the signal line and the power line go to the same trunking. Solution: The product function selected by the customer does not meet the on-site working conditions, and it needs to be installed or replaced.

Principle and characteristics of IFM capacitive sensors Principle and characteristics of IFM capacitive sensors

Capacitive sensors can detect any object without touch. In contrast to inductive sensors, which can only detect metals, capacitive sensors are also capable of detecting non-metallic materials. principle 1. The first thing to be measured is ...

Classification of ifm magnetic sensors Classification of ifm magnetic sensors

Any sensor made by using magnetic properties and magnetic flux changes is called a magnetic sensor. There are two common types of magnetic sensors: piezomagnetic sensors and magnetoelectric sensors. The two types of sensors are quite different in terms of operating principle and range of use. ...

Sensor performance indicators – ifm Sensor performance indicators – ifm

Selection of sensitivity In general, within the linear scale of the sensor, the higher the sensitivity of the sensor, the better. Because as long as the sensitivity is high, the value of the output signal corresponding to the measured change is relatively large, which is conducive to the signal processing.

ifm pressure sensors are prone to problems ifm pressure sensors are prone to problems

The first is pressure, and the transmitter cannot afford to lose it. In this case, check if the pressure connector is leaking or clogged, if not, check the wiring method and see if the power supply is normal, simple pressure to confirm if the output has been changed, or if there is an output at the zero point of the sensor ...

How to use load cells and amplifiers – ifm How to use load cells and amplifiers – ifm

1. Wiring according to wiring requirements 2. Connect the specified size DC power supply to the transmitter. 3. Connect the sensor and adjust it to the corresponding zero output value (the corresponding zero output value (e.g. 0-10V output. ...

Take you to know the proximity sensor - ifm Take you to know the proximity sensor - ifm

Proximity sensor is a general term for sensors that replace touch detection systems such as limit switches and aim at detecting objects without touching them. It converts the moving and possessive messages of the detected target into electrical signals. ...

Load cell wiring method – ifm Load cell wiring method – ifm

There are four-wire and six-wire load cells. Four-wire system: EXC EXC: Power cord, that is, the DC power supply supplied by the instrument to the sensor. SIG, SIG-: The signal line, that is, the signal line output by the sensor, is output to the instrument. In addition to the above four lines, there are more than two in the four-wire system: SEN, SEN-: feedback line ...

ifm UGT505 is used to improve air quality ifm UGT505 is used to improve air quality

Green City Solutions is committed to improving urban air quality. As a result, they developed CityTree, the world's first bio-skill air filter. The filter is integrated in the UGT505. CityTree uses ...

Introducing the ifm all-metal inductive sensors Introducing the ifm all-metal inductive sensors

Changes in mechanical spacing can be detected directly and parameterized easily via the IO-Link interface Interval measurement provides robust endpoint position detection High quality stainless steel housing (316L) The temperature scale is the most ...

Features of the S-type load cell – ifm Features of the S-type load cell – ifm

1. S-type load cells are moderately priced and suitable for mass production - good sensor consistency is required, suitable for automated batch production, and high requirements for processing equipment to eliminate inconsistencies and faults formed by manual operation. 2、 ...

Common faults of pressure sensors – ifm Common faults of pressure sensors – ifm

If the power supply is normal, it is necessary to carry out a simple pressurization to see if the output has changed, perhaps observe whether the zero position of the sensor has an output, assuming that it has not changed, the sensor has been damaged, otherwise it is the appearance of the damage or other links of the whole system. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top