Introduction: The Rosemount/Rosemount Vortex Flow Meter 8800DR120, an integrated diameter gauge that accurately measures low flow rates and maintains the same surface spacing as standard flanged vortex gauges.
Features:
The intelligent reducer design improves low-flow measurement performance
Built-in reducers eliminate the need for on-site assembly, simplifying installation and reducing cost and project risk
With the same face-to-face dimensions as traditional 8800 Series meters, instrumentation can be arranged without changing the piping layout
The isolated sensor design allows for in-tube replacement without breaking the process seal
The unique gasketless gauge body design increases plant availability and reduces potential leak points
Vibration resistance is achieved using a mass balance sensor and adaptive digital signal processing with vision filtering
Each flowmeter has a standard internal signal generator that simplifies the calibration of electronic components
With no moving parts and no repairs or maintenance, you save time and money
Product parameters
Flowmeter Accuracy:
± 0.65 % of liquid flow (±1.00% for 6-in (150 mm) and larger diameters)
± 1% of gas and vapor flow (±1.50% for 6-in (150 mm) and larger diameters)
Turndown ratio: 38:01:00
Output:
4-20 mA with HART®
4-20 mA with HART® and scalable pulse output
FOUNDATION™ fieldbus with 2 analog input blocks, 1 backup link active scheduler function block, and 1 integration circuit function block (1 optional PID function block)
Wetted Materials: Stainless Steel - 316 ⁄ 316L and CF3M Nickel Alloys - C-22 and CW2M, consult facility for other wetted material options
Flange Options: ANSI Class 150 to 1500 DIN PN 10 to PN 160 JIS 10K to 40K Flange styles available
Operating temperature: -330°F to 800°F (-200°C to 427°C)
Bore: Flanged - 1-in to 12-in (15 to 300 mm)
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount vortex flowmeter 8800DR120 product, if you are interested in Rosemount/Rosemount vortex flowmeter, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount ** Sonic Gas Ultrasonic Flow Meter USM341716
Introduction: Rosemount **Sonic Gas Ultrasonic Flow Meter USM341716, which leverages the power of the field-proven Rosemount four-channel string meter (OIML R137 1&2 accuracy class 0.5) designed by British Gas, combined with the use of ...
|
|
Rosemount/Rosemount General Purpose pH/ORP Sensor 389VP
Description: The Rosemount/Rosemount General Purpose pH/ORP Sensor 389VP uses a molded Tefzel® body and Viton® O-rings to make each sensor extremely difficult to damage and highly resistant to chemicals. The complete package eliminates leaks common with other pH/ORP sensors ...
|
|
Rosemount/Rosemount Plug-in/Immersion Conductivity Sensor 150
Introduction: Rosemount/Rosemount Plug-in/Immersion Conductivity Sensor 150
Features:
Ideal for use as a fixed-point detector when accurate measurements are not required over a wide radio conductance range
Suitable for plug-in or immersion applications
...
|
|
Rosemount/Rosemount Electromagnetic Sensor MS060 Accuracy±0.25%
Introduction: The Rosemount/Rosemount electromagnetic sensor MS060, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high solids fluids, long fiber slurries, or installations that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Vortex Flow Meter 8600DF015 outputs 4-20mA
Description: The Rosemount/Rosemount Vortex Flow Meter 8600DF015 is optimized for cost-effective general flow metering as well as clean fluid applications including steam, air, water, and nitrogen.
Features:
No moving parts, no repairs and no maintenance ...
|
|
Rosemount/Rosemount Carbon Monoxide Analyzer CCO 5500
Introduction: The Rosemount/Rosemount Carbon Monoxide Analyzer CCO 5500, the CCO 5500 Carbon Monoxide (CO) Analyzer uses infrared absorption spectroscopy to continuously measure the concentration of carbon monoxide in combustion flue gases. The infrared source is mounted directly on the flue gas duct or chimney on the opposite side of the receiver. Infrared...
|
|
The Rosemount/Rosemount Chip Electromagnetic Flowmeter Sensor 8711 has a turndown ratio of 13:1
Introduction: The Rosemount/Rosemount Chip Electromagnetic Flowmeter Sensor 8711 is designed to be flangless, economical, compact, and lightweight, and can replace flanged electromagnetic flowmeters. The product is available in a wide range of durable lining and electrode materials, from highly corrosive liquids to fibrous slurries ...
|
|
Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707200 Power Supply 115VAC
Introduction: The Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707200 provides enhanced signal strength along with excellent signal processing and superior filtration technology for the most difficult, noisy slurry applications.
Features:
...
|
|
The Rosemount/Rosemount Temperature Transmitter 3144P outputs 4-20mA
Introduction: The Rosemount/Rosemount Temperature Transmitter 3144P, Rosemount X-well technology accurately measures internal process temperatures without the need for thermowelling or process perforation. Process temperatures can be safely recorded without cutting pipes and flow frequencies or process shutdowns can be calculated. Convert each temperature ...
|
|
Rosemount/Rosemount Direct Fit Manifold R306 ** Maximum operating temperature 399°C
Introduction: The Rosemount/Rosemount Direct Coupled Manifold R306 can be assembled directly with a direct attach gauge or absolute pressure transmitter. Pressure-Lock™ valves are designed for use with Rosemount R305 and R306 to simplify operation, improve reliability, and improve operator safety. R306 ...
|
|
The Rosemount/Rosemount Pressure Transmitter 326P has a 4:1 turndown ratio
Description: The Rosemount/Rosemount Pressure Transmitter 326P is designed for pressure and hydrostatic level applications in the food and beverage industry. The transmitter is hygienically certified (3-A, FDA, EC 1935, etc.), has a polished stainless steel housing, and is equipped with a wide range of industry-standard process connections ...
|
|
Rosemount/Rosemount Level Switch 2110 Operating Pressure: -3.62—1450 psi
Introduction: Rosemount/Rosemount Level Switch 2110, The Rosemount 2110 Level Switch provides reliable level detection and reduces the need for maintenance for measurements in tight spaces and pipelines. Level applications and basic spill protection can be installed simply and quickly. Compliance with hygienic certifications, expanding the ...
|
|
Rosemount/Rosemount Sanitary Coriolis Meter H100S
Introduction: Rosemount Hygienic Coriolis Meter H100S, Coriolis Flow Meter made of 316L stainless steel, 3A/EHEDG certified, and finished up to 32Ra (0.8?m), is a hygienic application that requires high reliability, repeatability, and stable measurements.
|
|
Rosemount Electromagnetic Flowmeter 8750W360 Caliber 0.15-8in
Description: The Rosemount/Rosemount Electromagnetic Flowmeter 8750W360, with its reliable, all-welded coil housing and lightweight sensor design (IP68 rating) ensures that the meter is compatible with all utility, water and wastewater applications. Certified for drinking water.
Product Features ...
|
|
Rosemount/Rosemount Retractable pH/ORP Sensor 396R
Introduction: The Rosemount/Rosemount Retractable pH/ORP Sensor 396R, the Rosemount Model 396R sensor is designed to provide the longest service life in harsh, dirty applications where it is difficult to provide a separate sampling flow path and where large insertion depths are required. It is related to 1- ...
|
|
Rosemount/Rosemount In-Line Oxygen Analyzer 6888A Ambient temperature -40 to 70°C
Description: The Rosemount/Rosemount In-Line Oxygen Analyzer 6888A continuously and accurately measures the amount of oxygen in the flue gas of any combustion process. Accurate measurement of residual oxygen is critical to combustion reactions, reducing energy costs, improving safety, and reducing emissions. Rugged oxygen ...
|
|
The Rosemount/Rosemount In-Line Oxygen Analyzer CX1100 outputs 4-20mA
Description: The Rosemount/Rosemount In-Line Oxygen Analyzer CX1100 provides oxygen measurement in clean combustion applications. Get accurate oxygen measurements to optimize combustion reactions, reduce energy costs, and comply with environmental regulations. The equipment is fully welded and does not require reference gas.
|
|
Rosemount/Rosemount 148 Temperature Transmitter 4-20mA Simulation
Summary: The Rosemount 148 temperature transmitter is a standard unit that can be used with a variety of sensor type inputs and can be cost-effectively installed with higher measurement accuracy than direct-wire solutions. The transmitter is available in a DIN B top-mount configuration and has a ...
|
|
The Rosemount/Rosemount Transmitter 3051S MultiVariable™ has a 200:1 turndown ratio
Description: The Rosemount/Rosemount Transmitter 3051S MultiVariable™, a single device of a multivariable transmitter that measures differential pressure, static pressure, and process temperature. This multivariable transmitter is a cost-effective solution to reduce pipe penetrations, impulse pipes, and connection systems ...
|
|
Rosemount/Rosemount Plug-in Conductivity Sensor 141
Introduction: The Rosemount/Rosemount Plug-in Conductivity Sensor 141 is designed for clean, low conductivity applications. The 141 sensor comes with a 3/4" MPT process connection that can be mounted directly into the process pipe, vessel, or flow-through tee. The sensor offers up to 200° ...
|
|