    Product Introduction
    The Rosemount/Rosemount Plug-in Conductivity Sensor 141 is available with 0.2/cm and 1.0/cm optional battery constants for medium conductivity applications
Product Description
Introduction: The Rosemount/Rosemount Plug-in Conductivity Sensor 141 is designed for clean, low conductivity applications. The 141 sensor comes with a 3/4" MPT process connection that can be mounted directly into the process pipe, vessel, or flow-through tee. The sensor is available with high temperature options up to 200° C.
Rosemount/Rosemount Plug-in Conductivity Sensor 141

Features:

Selectable cell constants of 0.2/cm and 1.0/cm for medium conductivity applications

High temperature option for sensors used between 100°C and 200°C

The integrated cast aluminum junction box simplifies field wiring

Product parameters

Weight: 2 lb / 3 lb (1.0 kg / 1.5 kg) • Weight is rounded to the nearest 0.5 kg or full pound

Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.

This article introduces the Rosemount/Rosemount Plug-in Conductivity Sensor 141 product, if you are interested in Rosemount/Rosemount transmitter, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
More on that
Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707160 Power consumption 300W Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707160 Power consumption 300W

Description: The Rosemount/Rosemount Slurry Electromagnetic Flow Meter Sensor 8707160 provides enhanced signal strength along with advanced signal processing and superior filtration technology for flow metering stability in the most difficult, noisy slurry applications.   Features: ...

Rosemount/Rosemount Controller 3490 input 4-20 mA Rosemount/Rosemount Controller 3490 input 4-20 mA

Description: The Rosemount/Rosemount Controller 3490 provides control for any 4–20mA or HART-compatible transmitter. The backlit display clearly displays the measured values as well as the status of all inputs and outputs. Product development is customer-centric and utilizes easy-to-navigate menus ...

Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341212 Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341212

Introduction: Rosemount/Rosemount primary sonic gas ultrasonic flowmeters are USM341212 for non-legal-for-trade metering of natural gas, such as verification metering, pipeline balancing, storage measurement, production or moisture metering. Featuring Mark III electronics and two-channel measurement redundancy. ...

Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8721015 Tubing size 15-100mm Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8721015 Tubing size 15-100mm

Description: Rosemount/Rosemount electromagnetic flowmeter sensor 8721015 designed for food, beverage, and life sciences applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards. Features: Lightweight and compact ...

Rosemount Flanged Vortex Flow Meter 8800DF120 Rosemount Flanged Vortex Flow Meter 8800DF120

Introduction: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF120 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.   Features: Isolated sensor design allows for ...

Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381208 Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381208

Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter is a USM381208 two-channel design with field-replaceable sensors for accurate and repeatable measurements for verification metering, dispensing, leak detection, pipeline balancing, process measurement, and other non-custody transfer applications.

Rosemount/Rosemount Retractable Contact Conductivity Sensor 402 Ambient temperature 0–100°C Rosemount/Rosemount Retractable Contact Conductivity Sensor 402 Ambient temperature 0–100°C

Introduction: Rosemount/Rosemount Retractable Contact Conductivity Sensor 402, with the Rosemount 402 Retractable Conductivity Sensor, you will be able to accurately measure electrolytic conductivity in a wide range of applications, from high-purity water to cooled purified water. The Rosemount 400 sensor is very well suited to ...

Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensor 8721025 1/2-4in size Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensor 8721025 1/2-4in size

Description: Rosemount/Rosemount hygienic electromagnetic flowmeter sensors 8721025 designed for food, beverage, and life science applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.   Features: Light...

Rosemount/Rosemount Wireless Discrete Dual Input Transmitter 702 Materials: Low copper, aluminum, or stainless steel Rosemount/Rosemount Wireless Discrete Dual Input Transmitter 702 Materials: Low copper, aluminum, or stainless steel

Introduction: The Rosemount/Rosemount Wireless Discrete Dual Input Transmitter 702 is a cost-effective, ready-to-install unit that provides two inputs. With the safety and reliability of WirelessHART® technology, the transmitter provides access to the ...

Rosemount/Rosemount 148 Temperature Transmitter 4-20mA Simulation Rosemount/Rosemount 148 Temperature Transmitter 4-20mA Simulation

Summary: The Rosemount 148 temperature transmitter is a standard unit that can be used with a variety of sensor type inputs and can be cost-effectively installed with higher measurement accuracy than direct-wire solutions. The transmitter is available in a DIN B top-mount configuration and has a ...

Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416 Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416

Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416, a new custody-transfer meter with excellent linearity over the flow range, further reducing product loss and unspecified losses. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...

The Rosemount/Rosemount Radar Level Gauge 5900S ± 0.5mm accuracy The Rosemount/Rosemount Radar Level Gauge 5900S ± 0.5mm accuracy

Introduction: The Rosemount/Rosemount Radar Level Gauge 5900S has an accuracy of ±0.5 mm (0.020 in.) to minimize level measurement uncertainty. It enhances ...

Rosemount/Rosemount Corrosion and Erosion Monitoring System Permasense ET410 Rosemount/Rosemount Corrosion and Erosion Monitoring System Permasense ET410

Introduction: The Permasense ET410, a unique ultrasonic sensor that continuously measures pipe thickness and provides real-time insight into corrosion and erosion trends, is the Permasense ET410 corrosion and erosion monitoring system. The ET410 sensor system is a non-intrusive, battery-powered, fast...

Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341216 Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341216

Introduction: Rosemount Primary Sonic Gas Ultrasonic Flow Meter USM341216 for non-legal-for-trade metering of natural gas, such as verification metering, pipeline balancing, storage measurement, production or moisture metering. Featuring Mark III electronics and two-channel measurement redundancy. ...

Rosemount/Rosemount Retractable pH/ORP Sensor 398R Rosemount/Rosemount Retractable pH/ORP Sensor 398R

Introduction: The Rosemount/Rosemount Retractable pH/ORP Sensor 398R, the Rosemount 398R, with its Tefzel™ and titanium chemically resistant construction and patented TUpH™ reference junction, make it an ideal sensor for measuring the pH of demanding process liquids. ...

Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707100 consumes up to 300W Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707100 consumes up to 300W

Description: The Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707100 provides enhanced signal strength along with advanced signal processing and superior filtering technology for flow metering stability in the most difficult, noisy slurry applications. Features: ...

Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707030 Power 115VAC Rosemount/Rosemount Slurry Electromagnetic Flowmeter Sensor 8707030 Power 115VAC

Introduction: The Rosemount/Rosemount Slurry Electromagnetic Flow Meter Sensor 8707030 provides enhanced signal strength along with advanced signal processing and superior filtration technology for flow metering stability in the most difficult, noisy slurry applications. Features: ...

Rosemount/Rosemount Conductivity Sensor 403 PUR-Sense™ Rosemount/Rosemount Conductivity Sensor 403 PUR-Sense™

Introduction: Rosemount/Rosemount Conductivity Sensor 403 PUR-Sense™, Rosemount 403 and 403VP sensors are primarily used to measure conductivity in water for injection (WFI). The sensor can also be used in water purification systems in the food and beverage industry. Features: ...

Rosemount/Rosemount Continuous Gas Analyzer XECLD Rosemount/Rosemount Continuous Gas Analyzer XECLD

Description: Designed to detect ultra-low NOx emissions in industrial and commercial combustion, the Rosemount/Rosemount Continuous Gas Analyzer XECLD uses highly stable, solid-state chemiluminescence detection (CLD) technology to help operators demonstrate ...

Rosemount/Rosemount pH Sensor Hx338 Rosemount/Rosemount pH Sensor Hx338

Introduction: Rosemount/Rosemount pH Sensor Hx338, Rosemount Hx338+ Sensor offers a unique pre-pressurized pH reference technology for the biotechnology and pharmaceutical industries. The pre-pressurized reference does not allow process substances to leak into the sensor, thus preventing batch-to-batch contamination. pH ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top