Sensor controller host
specification
Main Units / Expansion Units | host | display | The smallest display unit | Z-axis | 10 µm *1 | X-axis | 50 µm *1 | Display range | Z-axis | ± 999.99 to ±999 mm (4 segments optional)*1 | X-axis | ± 999.95 to ±999 mm (4 segments optional)*1 | tool | Scan mode | HEIGHT, HEIGHT DIFFERENCE, AREA HEIGHT, PIN HEIGHT, MAX/MIN, HEIGHT AREA, BLACK & WHITE AREA, WIDTH, HEIGHT DIFFERENCE CALCULATION, THICKNESS CALCULATION, POSITION CORRECTION, 1-AXIS EDGE CORRECTION, 2-AXIS EDGE CORRECTION | Judgment tool: 16 tools, position correction tool: 1 tool*2 | Straight line mode | Height (AVE/MAX/MIN), Height Difference (AVE/MAX/MIN), Edge Position, Width/Diameter, Height Difference/Width Calculation, Thickness Calculation, Position Correction, Tilt Correction | Judgment tool: 16 tools*3, Position correction tool: 1 tool, Tilt correction: 1 tool*2 | Other features | general | ZERO/ offset, on-the-fly threshold change, 2-point calibration, measurement direction, measurement with position correction NG, ZERO/ offset memory, shooting mode (HDR), additional sensor date time | Information, N.O./N.C. switching, I/O monitor, automatic brightness adjustment, illumination (ON/OFF), comprehensive judgment conditions, NPN/PNP switching, simultaneous host/slave input, mutual interference prevention, password | Scan mode | Measurement Distance, Measurement Position (Small / Standard / Large), Measurement Mode, Measurement Interference Removal, Shooting Mode (High Gain), | Tilt Correction (Optional Fixed, Real-Time Correction), Halo Reduction, Trigger Input (Internal/External), Trigger Interval, Trigger Delay, Trigger Error, | Black and white histogram function, area height histogram function, datum area fixation, outline invalidation, rotation range, height image display in tool setting screen, zoom function | Straight line mode | Average times, laser position adjustment, TIMING input, sensor head tilt correction (fixed only), measurement ambient light cancellation, HOLD function, alarm setting, | Measurement method (average/maximum/minimum), laser sensitivity adjustment, average filter, median filter, X-axis median filter | input | input | Passive contact input / voltage input can be switched | Passive contact input: ON voltage 2 V or less, OFF current 0.1 mA or less, ON current 2 mA (in case of short circuit) | Voltage input: Maximum rated input voltage 26.4 V, ON voltage 18 V or more, OFF current 0.2 mA or less, ON current 2 mA (at 24 V) | Points | 8 points (IN1 to IN8) | function | IN1: External trigger↑↓ /TIMING, IN2 to IN8: can be assigned to any function | Assignable Functions: Program Switch, Stop Illumination, ZERO/ Offset (Batch), Reset (Error Only), Reset (Judgment Value Only), Reset (Judgment Value & Error) | output | output | The open collector output is NPN/PNP switchable and N.O./N.C. switchable | NPN open-collector output: 26.4 V max. 50 mA (20 mA when using the handset), residual voltage 1.5 V or less | PNP open-collector output: 26.4 V max. 50 mA (20 mA when using the handset), residual voltage 2 V or less | Points | 10 points (OUT1 to OUT10) | function | It can be assigned to any function | Assignable functions: Comprehensive judgment result (all OK/any OK/NG), Run, BUSY, error, position correction result, tilt correction result, logical operation result of each tool, | Black & White Area / Height Area Tool Results (OK/NG), Height / Height Difference /MAXMIN/ Calculation Tool Results (OK/NG/HIGH/LO), Alarm | Analog voltage output | ± 5 V, 1 to 5 V, 0 to 5 V output impedance 100 Ω*4 | Analog current output | 4 to 20 mA maximum load resistance 350 Ω*4 | Number of programs | 32 programs | Statistics | Scan Mode: Measured Value / Concordance (MAX, MIN, AVE), Processing Time (Latest Value, MAX, MIN, AVE), Count (OK / NG / Triggers) | Straight-line mode: Measured value / Consistency (MAX, MIN, AVE), Count (OK number / NG number / number of judgments) *1 *5 | Detection records | Save the quantity | Scan mode | 50 sheets (FTP client feature: active/high-resolution mode: active) | 80 sheets (FTP client feature: Active/High Resolution mode: Invalid) | 70 sheets (FTP client feature: invalid/high resolution mode: active) | 100 sheets (FTP client feature: invalid/high resolution mode: invalid) | *6 | Straight line mode | 400 sheets (FTP client features: Active/Hi-Res mode: -) | 500 sheets (FTP client feature: invalid/high-resolution mode: -) | *6 | Save the condition | NG only/ All selectable *6 | Image Data Transfer (FTP Client Function) | Transmission destination | FTP server | Transfer format | BMP/JPEG/TXT is optional | Transmission conditions | 4 conditions | All / Comprehensive judgment result (OK/NG) / Results of each tool (OK/(NG and ALM)) / Logical results of each tool (OK/NG) You can choose from | Ethernet | specification | 100BASE-TX/10BASE-T *7 | connector | RJ-45 8 pin connector *7 | Interfaces are supported | CC-Link, DeviceNetTM, EtherNet/IPTM, EtherCAT®, RS-232C, BCD output, TCP/IP protocol-less communication *8 | Number of units that can be connected | 1 host, 1 handset, and 1 communication unit (DL). | rated | Supply voltage | 24 VDC ±10% (including ripple) | Current consumption | Maximum 1.9 A or less (0.8 A or less when using the main unit only, 1.9 A or less when adding a handset) (excluding output load)*9 | Environmental resistance | Ambient temperature | 0 to +50°C (no freezing) | relative humidity | 35 to 85% RH (non-condensing) | Material | Main Chassis Housing: PC/ Power Connectors: PA, POM/ Analog Output Connectors: PA, POM/I/O Connectors: PA/ | Sensor Head Connector: Zinc +Ni Plating, PA/Ethernet Connector: Copper Alloy +Ni Plating / Rear Heat Sink of the Main Unit: Aluminum / | DIN rail fastener on the back of the main unit: POM/ nameplate :P C | weight | Approx. 210 g | *1 Displayed on the IX touch panel or PC software.
*2 Can be set according to the program.
*3 Diameter tool only, up to 8 pieces.
*4 Select one of ±5 V, 1 to 5 V, 0 to 5 V, 4 to 20 mA.
*5 When sample hold (edge), peak/valley, and P-P hold (horizontal/edge) are set.
*6 Saved in the internal memory of the sensor controller. The detection history, which is stored inside the sensor controller, can be backed up to a PC via a USB memory installed on the IX touch panel or PC software.
*7 Used to connect to IX touch panel or PC software. To connect the handset, you need to go through the RJ45 connector of the main unit.
*8 When using the DL series. For other interfaces, please contact KEYENCE.
*9 Includes DL series communication units.
This article introduces KEYENCE/KEYENCE multi-point laser sensor IX-H2000 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business
|
More on that
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-FB15N3
KEYENCE/KEYENCE Ultra-Small Amplifier Built-in Photoelectric Sensor PR-M/F Series Square Reflective Type (Background Suppression) Cable Type 15mm PR-FB15N3
specification
In this article, we introduce the KEYENCE/KEYENCE SUBMINIATURE AMPLIFIER built-in photoelectric sensor PR-M/F Series P ...
|
|
KEYENCE/KEYENCE Sensor Head LJ-V7200
KEYENCE Sensor Head LJ-V7200 Mounting Status: Diffuse Reflection
Reference distance: 200 mm
Enclosure rating: IP67 (IEC60529)*7
Ambient light: Incandescent lamp: 10,000 lux*8 max
Ambient temperature: 0 to +45 °C*9
Relative humidity: 85%RH to ...
|
|
KEYENCE/KEYENCE 3D Development Edition Controller LJ-X8000E
Compatible with 2D controller LJ-X8000E
Control inputs: 20 points (5 points for input terminal blocks, 15 points for parallel I/O)
Control output: 28 points (6 points for output terminal block, 22 points for parallel I/O) ・Photo MOSFET*3
Laser ON Input: No Voltage Input (Factory ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH250(10M)
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH250 (10M) Laser Sensor Amplifier Split Type Sensor Head (Detection Distance: 250mm) with a cable length of 10m
*1 According to Laser Notice No. 56 of the FDA (CDRH), the classification is carried out according to the IEC60825-1 standard.
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-B01
Squared Standard mounting metal parts
Type: Flat standard mounting bracket
Number of Builts: 1pcs
Material: SUS316L
Note: Comes with M3 screw×2
Weight: approx. 8 g
In this article, we introduce the KEYENCE/KEYENCE ultra-compact amplifier built-in photoelectric sensor PR-M/F Series O...
|
|
KEYENCE/KEYENCE amplifier built-in TOF laser sensor LR-T series MU-CB2
Power cable for MU-N series
End Shape: Cable Termination: 2 Core Loose Wire, Controller: Connector
Length: 2 m
Material: PVC (Vinyl Chloride)
Remarks: For extended units
Weight: approx. 100 g
This article introduces the KEYENCE/KEYENCE amplifier built-in TOF laser ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH50(10M)
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH50 (10M) Laser Sensor Amplifier Split Type Sensor Head (Detection Distance: 50 mm) with a cable length of 10 m
*1 Classified according to Laser Notice No. 56 in the FDA (CDRH) on the IEC60825-1 basis ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series M8 Connector Type Cable OP-88505
KEYENCE/KEYENCE Laser Sensor LR-X Series M8 Connector Type Cable High Elasticity 2 m OP-88505
Type: High elasticity
Sensor side: M8 4pin straight
Cable termination: Loose wires
Length: 2 m
Material: Cable part :P VC connector ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor IX-1000
Sensor controller main unit
specification
*1 Displayed in the control panel for IX or in the PC software.
*2 Can be set according to the program.
*3 Select one of ±5 V, 1 to 5 V, 0 to 5 V, 4 to 20 mA.
*4 Set sample hold (edge), peak/valley ...
|
|
KEYENCE/KEYENCE Optoelectric Sensor with Built-in Amplifier PR-M/F Series OP-87670
Slit plate φ0.5 square use
Type: Slender for flat surfaces
Number of Builts: 1pcs
Slit plate size: ø0.5
Material: SUS304
Remarks: ・Detection distance: 30mm (when both transmit and receiver sides are attached) ・Transmission type only
Weight; About 1 g
This article introduces KEYENCE's ...
|
|
KEYENCE/KEYENCE Controller PNP Type LJ-G5001P
Controller PNP type LJ-G5001P
Key features:
Sensor head calculation, contour adjustment, filter, smoothing, averaging, position adjustment, OUT name change, measurement mode selection
(Height, Position, Gap, Width, Center Position, Cross-sectional Area, Crossing, Angle, Contour Ratio...)
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH100(10M)
KEYENCE/KEYENCE LR-XH100 (10M) Laser Sensor Amplifier Split Type Sensor Head (Detection Distance: 100mm) with a cable length of 10m
*1 Classified according to Laser Notice No. 56 in the FDA (CDRH) according to the IEC60825-1 standard.
This article introduces the ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-X50C (Detection Distance: 50mm)
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-X50C Laser Sensor Standard M8 Connector Type (Detection Distance: 50mm)
*1 The cable length of the M8 connector type is 30 m or less. When connecting IO-Link, keep it to less than 20 m.
*2 Select 500 μs ...
|
|
KEYENCE/KEYENCE Optoelectric Sensor with Built-in Subminiature Amplifier PR-M/F Series OP-85497
Connector cable M8L word 2m PVC
specification
This article introduces the KEYENCE/KEYENCE ultra-small amplifier built-in photoelectric sensor PR-M/F series OP-85497 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your visit.
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-B05
Mini slim side-mounted metal parts
Type: Small slender side mount
Number of Builts: 1pcs
Material: SUS316L
Remarks: Comes with M3 screw×2, plate nut
Weight: approx. 10 g
This article introduces the KEYENCE/KEYENCE ultra-small amplifier built-in photoelectric sensing ...
|
|
KEYENCE/KEYENCE Photoelectric Sensor LR-W Series Power Supply 10 to 30VDC
Introduction: The unique technology used in the LR-W series gives it the ability to analyze the full spectrum. The series detects all differences, from surface finish differences that are difficult to see with the naked eye to color changes. The LR-W's metal housing and IP65/67 enclosure rating allow it to withstand the harsh environment of the environment.
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH250
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH250 Laser Sensor Amplifier Split Type Sensor Head (Detection Distance: 250mm) with a cable length of 2 m
*1 Classified according to Laser Notice No. 56 in the FDA (CDRH) according to the IEC60825-1 standard.
This paper...
|
|
KEYENCE/KEYENCE photoelectric sensor PZ-M series control output 100mA
Introduction: KEYENCE's stand-alone photoelectric sensor PZ-V/M series uses a laser sensor with distance principle detection, which is not easily affected by the color and tilt of the workpiece, and performs stable detection. Unaffected by highly reflective target backgrounds, it is highly resistant to dust and dirt.
...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XN12N
KEYENCE/KEYENCE Laser Sensor Amplifier Discrete Amplifier Cable Type Expansion Unit NPN LR-XN12N
*1 When 500 μs is selected, the following limits are specified.
· Tuning is limited to 2-point tuning.
· The detection range shield is set during tuning. (The screen is not supported...)
|
|
KEYENCE/KEYENCE amplifier built-in TOF laser sensor LR-T series MU-CB8
Power cable for MU-N series
End Shape: Cable Termination: 8-core loose wire, Controller: Connector
Length: 2 m
Material: PVC (Vinyl Chloride)
Remarks: For the main unit
Weight: approx. 150 g