Introduction: The Rosemount/Rosemount Flow-Through Loop Conductivity Sensor 242, the Rosemount 242 Loop Conductivity Sensor is a non-intrusive flow-through design that can be installed in-tube without blocking the sampling flow path. This sensor is ideal for conductivity measurement applications with high conductivity liquids with a conductivity of up to 2 S/cm (2,000,000 μS/cm) and can be used with viscous, abrasive, or fibrous liquids.
Features:
Reliable measurement - insensitive to process flow and direction
It is not easy to clog and is suitable for liquids containing large amounts of suspended solids
No parts reach into the sample stream, preventing solids build-up
In-line calibration reduces downtime
Available in 25, 40, 50, 80 and 100 mm diameters (1, 1.5, 2, 3 and 4 inches) with ANSI and DIN compatible flanges
A wide range of liner and O-ring materials to ensure process compatibility
The all-in-one junction box simplifies the wiring process
Product parameters
Measuring range: Conductivity range: 100 μS/cm to 2 S/cm
Weight:
1" to 2": 10kg (22 lbs.)
3" to 4": 39 kg (86 lbs.)
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount flow-through ring conductivity sensor 242 products, if you are interested in Rosemount/Rosemount electromagnetic flowmeter, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount Retractable Contact Conductivity Sensor 402 Ambient temperature 0–100°C
Introduction: Rosemount/Rosemount Retractable Contact Conductivity Sensor 402, with the Rosemount 402 Retractable Conductivity Sensor, you will be able to accurately measure electrolytic conductivity in a wide range of applications, from high-purity water to cooled purified water. The Rosemount 400 sensor is very well suited to ...
|
|
Rosemount/Rosemount vortex flowmeter 8600DF030 outputs 4-20mA
Description: The Rosemount/Rosemount Vortex Flow Meter 8600DF030 product is optimized and cost-effective for general flow metering as well as clean fluid applications including steam, air, water, and nitrogen.
Features:
No moving parts, no repairs and maintenance ...
|
|
The Rosemount/Rosemount Low Flow Conductivity Sensor 404 cable is 3.1m in standard length
Introduction: The Rosemount/Rosemount Low Flow Conductivity Sensor 404 can be used to measure the conductivity of clean water. The sensors and flow cells are combined into a separate package. Because the retention volume of the flow cell is small, it reacts more quickly to sudden changes in conductivity and temperature. 404 Sensing ...
|
|
Rosemount/Rosemount Multi-Instrument Flange MIF-61 Accuracy±2mm
Introduction: Rosemount/Rosemount Multi-Instrument Flange MIF-61, in order to meet regulations regarding emissions, many ships are transitioning to liquefied natural gas (LNG) or liquefied petroleum gas (LPG) as their primary fuel source due to low sulfur emissions. However, this shift has given ...
|
|
Rosemount/Rosemount 4+1 Dual-Configuration Gas Ultrasonic Flowmeter 3415
Introduction: The Rosemount/Rosemount 4+1 Dual-Configurable Gas Ultrasonic Flowmeter 3415, the Rosemount 3415 4+1 Ultrasonic Flowmeter combines a field-proven Rosemount four-channel British Gas string meter (validated to OIML R137 1&2 accuracy class 0.5) and ...
|
|
Rosemount Vibrating Tuning Fork Level Switch 2521 Working pressure 16 bar
Introduction: Rosemount/Rosemount Vibrating Fork Level Switch 2521, Rosemount 2521 Vibrating Tuning Fork Level Switch is suitable for applications that require high sensitivity, such as the measurement of fine particles and powdery media in storage and process vessels. It is a highly sensitive and easy-to-use ...
|
|
Rosemount/Rosemount Four-Vortex Flow Meter 8800DQ020 with a turndown ratio of 15.1
Description: The Rosemount/Rosemount Quad Vortex Flow Meter 8800DQ020 with a fourth integrated transmitter for process control provides the ultimate redundant flow measurement solution to prevent false trips with a two-of-three vote. The 8800 Quad Vortex Flowmeter has an out...
|
|
Rosemount/Rosemount Power Locator Hagan Repeatability 1.0%
Introduction: Rosemount/Rosemount Power Locator Hagan, the industry needs a powerful force to accurately control process valves, dampers, and feed mechanisms and react to demand signals. Emerson's Rosemount Analytical Pneumatic Power Positioners consistently meet these demanding control requirements, with ...
|
|
Rosemount In-Line Oxygen Analysis, Oxymitter™ 4000, protocol, 4-20mA
Introduction: The Rosemount/Rosemount In-Line Oxygen Analysis Oxymitter™ 4000 is the world's first in-line zirconia oxygen analysis transmitter for flue gas measurement, up to explosion-proof level. These oxygen content measurements are available ...
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF100 with a turndown ratio of 38:01:00
Description: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF100 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Quad Vortex Flow Meter 8800DQ100 has a turndown ratio of 15.1
Description: The Rosemount/Rosemount Quad Vortex Flow Meter 8800DQ100 with a fourth integrated transmitter for process control provides the ultimate redundant flow measurement solution to prevent false trips with a two-of-three vote. The 8800 Quad Vortex Flowmeter has an out...
|
|
Rosemount Electromagnetic Flowmeter Sensor 8711015 4-200mm
Description: The Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8711015 and offers a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, size and weight are the most ...
|
|
Rosemount/Rosemount Gas Ultrasonic Flow Meter 3410 10.4 VDC—36 VDC
Introduction: The Rosemount/Rosemount Gas Ultrasonic Flow Meter 3410, the next generation of Rosemount 3410 Series electronics quickly processes critical gas ultrasonic flow data to ensure that changing flow dynamics are communicated in seconds. As with all Rosemount 3410 Series ...
|
|
Rosemount/Rosemount Radar Level Gauge 5900C SIL2 Safety Certified
Description: The Rosemount/Rosemount Radar Level Gauge 5900C provides ± 2 mm (0.08 in.) accuracy. It is often used in conjunction with a high-precision multi-point temperature sensor to calculate the net volume. It is SIL 2 certified and complies with IEC 61508.
Give birth...
|
|
Rosemount/Rosemount In-Line Oxygen Analyzer 6888A Ambient temperature -40 to 70°C
Description: The Rosemount/Rosemount In-Line Oxygen Analyzer 6888A continuously and accurately measures the amount of oxygen in the flue gas of any combustion process. Accurate measurement of residual oxygen is critical to combustion reactions, reducing energy costs, improving safety, and reducing emissions. Rugged oxygen ...
|
|
Rosemount/Rosemount Electromagnetic Sensor MS140 Pipe size 80-900mm
Introduction: The Rosemount/Rosemount Electromagnetic Sensor MS140, MS Slurry Sensor is a reliable solution for difficult-to-measure applications such as grit, high-solids fluids, long-fiber slurry, or installations that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW040
Description: The Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW040 provides a cost-effective, lightweight alternative to flanged vortex flow meters. The compact, space-saving design is versatile and can be installed in any location
Product Features ...
|
|
The Rosemount/Rosemount Low Temperature Sensor 614 has an accuracy of ± 0.02 °C
Introduction: The Rosemount/Rosemount Cryogenic Point Temperature Sensor 614 is designed for temperature measurement in cryogenic and refrigerated storage tanks. These point temperature elements are routed using mineral-insulated, flexible steel cables to measure the internal temperature of a fully loaded tank during cooling and to detect tank isolation during cooling.
|
|
Rosemount Flanged Vortex Flow Meter 8800DD120
Description: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DD120 features redundant, independent sensors and electronics to help avoid false starts. Suitable for safety interlock systems and related applications.
Features:
The isolated sensor design allows for a process without destroying the process code.
|
|
Rosemount/Rosemount High Performance pH & ORP Sensor 3300HTVP
Introduction: Rosemount/Rosemount High Performance pH and ORP Sensor 3300HTVP, Rosemount 3300HTVP PERpH-X High Performance pH/ORP Sensor is designed to be durable and can significantly extend the life of the sensor in a variety of complex applications. This retrofittable sensor is used in high ...
|
|