There are many special faults, which come and go, looming, making it impossible to judge and deal with. At this time, you can clean the circuit board with water or alcohol, brush off the dust and rust on the circuit board with a soft brush, pay special attention to the dense solder joints, and the circuit near the 0 volt copper layer should also be cleaned and cleaned, and then dried with hot air. Unexpected effects are often achieved. At least facilitate the use of observational methods.

                                 Inverter maintenance and cleaning inspection method - Senlan inverter

Example 1, the problem of a frequency converter is not displayed, through the start of detection, the rectifier part and the inverter part are intact, so the power on inspection. The DC bus voltage is normal, but the starting voltage of the switching power supply control chip 3844 is only 2V. The on-line detection of the resistance of the voltage divider resistor is much smaller, and the off-line detection is normal. After the scrubbing method is selected, the problem is solved. It turns out that the positive pin pad of a capacitor is very close to the 0V layer, and the residual flux makes it semi-conductive.

Example 2: When the inverter is sent, there are several different alarm records. During the power-on test, various false alarms appeared in the same way. After carefully cleaning the solder joints of the flat cable socket connecting the control board and the driver board, the problem is solved.
More on that
Inverter dustproof method - Sunland inverter Inverter dustproof method - Sunland inverter

1. Plan a special inverter room When the power of the inverter is large or the number is large, a special inverter room can be planned. The doors, windows and cable holes in the room need to be sealed to avoid dust ingress; It is necessary to plan air filtration equipment and circulation channels to adhere to the normal indoor air ...

The cause of vibration and noise in the inverter - Sunland inverter The cause of vibration and noise in the inverter - Sunland inverter

Generally speaking, the inverter will inevitably present some problems during operation, such as oscillation and noise, which are common problems in VFD operations. So, what causes oscillation and noise in VFDs? What is the solution to these problems? Here are the causes of VFD oscillation and noise ...

PLC control belt conveyor soft start method PLC control belt conveyor soft start method

Belt conveyor is a kind of continuous conveyor, which is one of the main types of fixed or escorted cranes. Belt conveyor is the use of friction to convey the dynamic, with belts, steel belts, steel fiber belts and chemical fiber belts as a kind of compliance with the transmission of materials and traction operations.

Servo motor regular diagnosis and repair method - Senlan Servo motor regular diagnosis and repair method - Senlan

1. Common faults of motor heating up too high or smoke motor Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low; Overhaul...

The overload capacity of the dry-type transformer - Sunland inverter The overload capacity of the dry-type transformer - Sunland inverter

Dry-type transformer is a kind of power equipment, and under normal circumstances, dry-type transformer also requires a certain amount of overload, that is, the workload beyond its working ability. So what about the overload of dry-type transformers and how to influence them? ...

Overload trip analysis of an inverter Overload trip analysis of an inverter

The motor is able to rotate, but the operating current exceeds the rated value, which is called an overload. The fundamental reflection of overload is that although the current exceeds the rated value, the fluctuation of the excess is not large, and it generally does not constitute a large inrush current. 1. The main reason for overload (1) Excessive mechanical load ...

Sunland inverter is used in Baotou steel water supply Sunland inverter is used in Baotou steel water supply

In recent years, with the development of power electronics skills, the frequency conversion speed regulation skills have been very mature, practice has proved that the use of frequency conversion speed regulation in fans, pumps and loads can save 20%-50% of the electric energy, and the use of frequency conversion speed regulation can bring the following advantages in the future, its biggest advantage is that it has ...

The reason for using frequency conversion speed regulation - Senlan The reason for using frequency conversion speed regulation - Senlan

Now, the frequency conversion speed regulation system has been widely used in the industrial production of various small and medium-sized enterprises. This is all due to our ability to provide accurate speed control and complete stepless speed regulation. Therefore, it can easily control the ascent and descent of mechanical transmissions, traverse ...

How to carry out electrical system commissioning quota? ——Sunland inverter How to carry out electrical system commissioning quota? ——Sunland inverter

The commissioning of the electrical system refers to the commissioning of the entire high and low voltage system. The power supply commissioning of civil electrical projects such as general residences, schools, office buildings, hotels, and shops shall be carried out in accordance with the following provisions: (1) About the commissioning of the belt in the distribution room ...

How to carry out frequency conversion of frequency converter - Senlan How to carry out frequency conversion of frequency converter - Senlan

(1) Rectifier. As one of the most important components of the inverter, the rectifier can convert the AC power into direct current. Its working method is more common to that of a battery charger or arc welder. It uses a diode bridge to limit the communication sine wave to only one direction.

Inverter control motor speed method - Senlan Inverter control motor speed method - Senlan

1. Why can the rotation speed of the motor be changed freely? The unit of motor rotation speed: r/min the number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz3000 [r/min] 4-pole motor 50Hz1500[r/min] Conclusion: The rotation of the motor ...

Characteristics of two-phase electric fan inverter - Sunland inverter Characteristics of two-phase electric fan inverter - Sunland inverter

The digital signal processor is selected, and the work efficiency is higher A good quality two-phase electric fan inverter uses a digital signal processor, which can make the work efficiency higher, that is, it may take 3 hours to complete the work, but now it only takes 2 hours to be able to...

Hope Sunland launched the new Hope800 series inverter Hope Sunland launched the new Hope800 series inverter

Hope Sunland Technology Co., Ltd. is a national key high-tech enterprise dedicated to the research and development of high, medium and low voltage frequency conversion technology and the design, development, production, sales and service of related products.

Sunland SBH series high-voltage inverter eight development direction cases Sunland SBH series high-voltage inverter eight development direction cases

The following application case of Sunland SBH series high-voltage inverter is a very comprehensive display of the eight development directions of high-voltage inverter High-voltage inverters, petrochemicals, mining, electricity Application plan 1 petrochemical occupation: Senlan twin ...

The reason for the explosion of the inverter module - Senlan inverter The reason for the explosion of the inverter module - Senlan inverter

1. Condensation The temperature difference in the workshop is large, and the inside of the inverter presents condensation. 2. Impact load. The load fluctuates greatly, and the output current of the inverter suddenly increases, resulting in module damage. 3. The inverter is overloaded in the start, ...

Common problems in the use of inverters - Hope Sunland Common problems in the use of inverters - Hope Sunland

1. Please clarify the maintenance function of the inverter? (1) After detecting the abnormal situation, take the initiative to correct the action, such as overcurrent loss speed prevention, regeneration overvoltage stall prevention. (2) Block the power semiconductors after detecting the abnormality...

The inverter is different from the inverter power supply - Senland The inverter is different from the inverter power supply - Senland

In terms of power supply, everyone may know that the inverter and the inverter power supply are auxiliary equipment for charging electrical appliances, but many people do not know what is the inverter power supply and what is the inverter. With the continuous progress of the times, electrical appliances will be constantly updated, and auxiliary equipment is constantly changing.

Attention to the shortcomings of the inverter - hope Senlan Attention to the shortcomings of the inverter - hope Senlan

The wiring interval between the motor and the inverter is too long, causing the new motor to catch fire Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, ...

Senlan wiring knowledge Senlan wiring knowledge

1. Wiring of fire emergency lighting Generally, the flame retardant wire is used to wear the metal pipe and the thickness of the protective layer is ≥ 30mm, in the decoration project, when the emergency lighting circuit can only be applied to the ceiling, the heat-resistant or fire-resistant wire should be selected and the fire-resistant and heat-resistant matching should be considered.

The main circuit of the inverter application - Hope Sunland The main circuit of the inverter application - Hope Sunland

There is a circuit breaker QF and a communication contactor KM between the power supply and the inverter, when the inverter does not need to be used for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. It has maintenance functions such as overcurrent and undervoltage. The main power of the inverter ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top