Delixi CDI-EM60 inverter technical characteristics

Create Date: 2024-8-30 12:03:23|Source: Delixi

Delixi CDI-EM60 inverter has optimized open-loop vector control, V/F control, stable function, optimized function, standard configuration of common users, but also expand multi-channel I/O interface and communication function, is a delicate type of small power type.

                               Delixi CDI-EM60 inverter technical characteristics

Technical features:

1. Miniaturized size, easy to operate, including DC braking and optional built-in braking unit, high accuracy of shutdown azimuth

2. Independent keyboard, the keyboard can be externally introduced and supports hot-swappable, the maximum distance of external quotation can be up to 50 meters, and the keyboard with parameter replication function can be optional.

3. Expandable RS485 communication interface, realize standardized MODBUS-RTU communication protocol, and connect with all kinds of host computers.

4. Long life planning, controllable fan. The AVR function (Active Voltage Regulation) ensures high output torque at low input voltages. A variety of maintenance functions ensure the safe and reliable operation of the motor.

5. All standard products are treated with conformal paint.

6. Independent air duct planning and wind plate blocking technology ensure good heat dissipation of the inverter, which greatly improves the environmental adaptability of the product.
More on that
Delixi Electric CDW3 universal circuit breaker introduction Delixi Electric CDW3 universal circuit breaker introduction

The CDW3 series frame circuit breakers are rated from 400A to 6300A and 415V/690V AC for extreme environmental conditions of 50 Hz AC and -40°C to 70°C. It is mainly used in the distribution network, distributing electric energy, protecting lines and power supply equipment from ...

How to wire and use the number of switches when the inverter starts and stops - Delixi How to wire and use the number of switches when the inverter starts and stops - Delixi

The control of the inverter is nothing more than the fundamental logic of starting, aborting, forward rotation, rotation, and speed regulation, which fundamentally requires that the level condition is effective, rather than the rising edge is effective, so the use of button switches to control the inverter is generally required to use the self-protection of the button...

The operating structure of the high-voltage circuit breaker - Delixi The operating structure of the high-voltage circuit breaker - Delixi

1. Classification of switch operation organization At present, the switches we encounter are generally divided into many types, such as oil-rich type (old model, now you can't see it at all), oil-poor type (some user stations also have it), SF6, vacuum, GIS (combined electrical appliances) and so on. These are all about the arc extinguishing medium of the switch. ...

Delixi contactor common faults Delixi contactor common faults

After long-term use or too frequent movements, or improper daily maintenance, problems may occur during operation and affect the normal operation. Frequently asked questions are as follows: 1. Coil problem The first problem with the coil is because of the ...

Introduction of molded case circuit breaker - Delixi Introduction of molded case circuit breaker - Delixi

Delixi plastic case circuit breaker is also called equipment circuit breaker, the external contact of the grounding terminal, arc extinguisher, tripper and operating organization are installed in a plastic shell. Auxiliary contacts, undervoltage trippers, parallel trippers, etc. Most of them are modular, very compact in structure, and generally do not consider maintenance ...

Choose the right inverter method - Delixi Choose the right inverter method - Delixi

The type of inverter is selected according to the type of production machinery, speed regulation range, static speed accuracy, and starting torque requirements, and it is most appropriate to decide which inverter is the most suitable to use. The so-called suitability is not only easy to use, but also economical, to meet the basic conditions and requirements of technology and production. ...

Delixi product parameter unit VF and V difference Delixi product parameter unit VF and V difference

Voltage vf and v difference: The two have different meanings, vf on the battery represents the feedback voltage, while v represents the capacity of the battery, which is the unit of measurement of voltage. Lithium battery is a kind of battery with lithium metal or lithium alloy as the positive/negative electrode data and the use of non-aqueous electrolyte solution. ...

What are the advantages and disadvantages of dry and oil regulators? - Delixi What are the advantages and disadvantages of dry and oil regulators? - Delixi

Oil Regulator: Also known as non-contact inductive regulator or intelligent non-contact regulator (only the name of the company's own selling point). Forte: 1. No contact, no protection, impact resistance (especially instantaneous impact, 2 times of normal.) The reason for this is the slow response, which ...

Delixi voltage regulator fault performance and elimination Delixi voltage regulator fault performance and elimination

Regulator problem 1: The regulator cannot be started Reason: Whether the phase sequence of the input power cord has been changed, and the air switch in the machine is not turned on or broken. Repair methods: 1. Swap the two power supply wires arbitrarily or check whether the power supply line is correct; 2. Close or replace the switch. Voltage Regulator ...

The role of Delixi AC voltage regulator The role of Delixi AC voltage regulator

Delixi high-precision fully active AC voltage regulator uses linear integrated circuits to form a control system, controls the servo motor, drives the contact voltage regulator to actively regulate the voltage, and is equipped with delay, overvoltage, undervoltage and overcurrent maintenance functions. The product has high efficiency, the same input and output voltage waveforms, and the output ...

Delixi time control switch adjustment method Delixi time control switch adjustment method

Press the undo function key first, then press and hold the school time function key, then adjust the time and date to the current moment, press the punctual function key again, adjust the time that needs to be closed and open to the specified value, if you need to set multiple groups, then press the punctual function key to set, without multiple groups ...

Delixi inverter selection principles and steps Delixi inverter selection principles and steps

Inverter selection is a skill, if the selection is not appropriate, it may damage the inverter explosion, and seriously affect the normal production of the factory, so it is very important to select the inverter scientifically and reasonably. The following are the principles of inverter selection: ...

Delixi inverter all aspects of the selection of precautions Delixi inverter all aspects of the selection of precautions

The inverter is a device that can control the speed of the motor, and it completes the speed regulation by adjusting the voltage and frequency of the motor. When selecting an inverter, there are several factors to consider, including the power of the motor, the type of load, the operating environment, etc. This article will specifically introduce the selection of frequency converters ...

Delixi inverter fault maintenance Delixi inverter fault maintenance

Delixi inverter is a commonly used inverter, how to maintain in the event of failure?   Constant speed overcurrent: When the inverter is running at a constant speed, the output current exceeds the current value. Check whether the output circuit of the inverter is short-circuited. Check if the input voltage is low. Examine...

The general principle of circuit breaker selection - Delixi The general principle of circuit breaker selection - Delixi

(1) The additional operating voltage of the circuit breaker ≥ the additional voltage of the line. (2) The additional current of the circuit breaker ≥ the line load current. (3) The additional short-circuit of the circuit breaker can be turned on and off to ≥ the maximum shortness that may be present in the line.

Delixi molded case circuit breaker external two tripping wire connection Delixi molded case circuit breaker external two tripping wire connection

The molded case circuit breaker tripper is divided into undervoltage tripper and shunt tripper. This article explains the wiring method of the circuit breaker with sub-excitation tripper. The shunt tripper is often used as an additional accessory for the user, it is a remotely operated circuit breaker disconnection device, installed in the molded case circuit breaker, when the shunt ...

A brief introduction to three-phase transformer - Delixi A brief introduction to three-phase transformer - Delixi

All large AC power blocks are connected by a three-phase transformer for transmission and distribution at high voltage levels. Single-phase transformers can be electrically connected to form a three-phase transformer bank in a distribution system. But the standard is to combine a single phase coil into a three-phase transformer unit on a common core ...

Problems in the installation and use of Delixi voltage regulator Problems in the installation and use of Delixi voltage regulator

What is the voltage regulator can not be connected in parallel, the voltage regulator is not open for a long time, what will be the problem with the voltage regulator still open under normal voltage, is it said that the voltage regulator and the undervoltage lamp is not lit to clarify that the voltage regulator is normal? Will a normally open regulator burn it out at normal voltage? ...

The circuit breaker is set in accordance with the principle - Delixi circuit breaker The circuit breaker is set in accordance with the principle - Delixi circuit breaker

1. When the main circuit is equipped with a total leakage maintainer, the main barrier switch, the branch barrier switch, the main circuit breaker, the branch circuit breaker or the main fuse, and the shunt fuse should also be installed. When the total leakage maintainer is a leakage circuit breaker with short-circuit, overload, and leakage maintenance functions, it can not be ...

Classification of low-voltage electrical appliances - Delixi Classification of low-voltage electrical appliances - Delixi

1. Classified according to the operating voltage level Low-voltage electrical appliances: electrical appliances used to communicate circuits below 1200V and DC 1500V to play the role of on/off, protection, control or regulation. High-voltage electrical appliances: communication 1200V or more, DC 1500V or more. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383