Introduction: The Rosemount/Rosemount clip-on electromagnetic flowmeter sensor 8711080 and the flangeless design provides a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
The flangeless structure has the smallest size and weight, which helps to reduce costs
Compact form factor, ideal for installations with a limited number of straight pipe positions
Suitable for any process application with available rugged linear options and standard, grounding, and warhead electrodes
The lightweight, flangeless design simplifies installation
The all-welded design eliminates the need for gaskets and prevents moisture ingress.
The unobstructed design with no moving parts minimizes the need for maintenance and repairs
Use a removable, replaceable terminal block to avoid process downtime and enable on-site repairs
Product parameters
Accuracy: Up to 0.15% volumetric flow accuracy at 13:1 and 0.25% at 40:1
Diameter: 0.15-8 in (4-200 mm)
Lining materials: ETFE, PTFE and PFA
Electrode material: 316L stainless steel, nickel alloy, platinum, tantalum, titanium
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount Clip-on Electromagnetic Flowmeter Sensor 8711080 products, if you are interested in Rosemount/Rosemount Sensor, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount Vortex Flow Meter 8600DF080
Description: The Rosemount/Rosemount Vortex Flow Meter 8600DF080 is optimized and cost-effective for general flow metering as well as clean fluid applications including steam, air, water, and nitrogen.
Features:
Flowmeter accuracy
Liquid flow ...
|
|
Rosemount/Rosemount Primary Sonic Gas Ultrasonic Flowmeter USM341206
Introduction: Rosemount/Rosemount primary sonic gas ultrasonic flowmeters are USM341206 for non-legal-for-trade metering of natural gas, such as verification metering, pipeline balancing, storage measurement, production or moisture metering. Featuring Mark III electronics and two-channel measurement redundancy.
...
|
|
Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381218
Introduction: The Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381218, two-channel design, field-replaceable sensor, high accuracy and repeatability of measurement results, suitable for verification metering, distribution, leak detection, pipeline balancing, process measurement, and other non-trade transactions.
|
|
Rosemount/Rosemount Flanged Electromagnetic Flowmeter Sensor 8705025
Description: The Rosemount/Rosemount flanged electromagnetic flowmeter sensor 8705025 all-welded construction provides an airtight port for moisture and contaminant protection, while the junction box is removable and replaceable for easy field service.
Features:
In order to achieve maximum ...
|
|
Rosemount Flanged Vortex Flow Meter 8800DF040
Introduction: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF040 eliminates potential leaks with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF080 Turndown ratio 38:01:00
Introduction: The Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF080 eliminates potential leak points with a gasket-free, anti-clogging gauge body. Discrete sensors facilitate the replacement of flow and temperature sensors without damaging the process seal.
Features:
Isolated sensor design allows for ...
|
|
Rosemount/Rosemount Clamp-on Electromagnetic Flowmeter Sensor 8711010
Description: The Rosemount/Rosemount clip-on electromagnetic flowmeter sensor 8711010 and flangeless designs provide a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, dimensions and ...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416
Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416, a new custody-transfer meter with excellent linearity over the flow range, further reducing product loss and unspecified losses. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Toroidal Conductivity Sensor 228 stainless steel
Description: The Rosemount/Rosemount Toroidal Conductivity Sensor 228 performs well in high conductivity liquids up to 2S/cm (2,000,000uS/cm). These sensors can still function in dirty and corrosive environments where metal electrode sensors can fail. Reliable...
|
|
Rosemount/Rosemount Thin Slice Vortex Flow Meter 8800DW005 with a turndown ratio of 38:01:00
Description: The Rosemount/Rosemount Thin Slice Vortex Flow Meter 8800DW005 provides a cost-effective, lightweight alternative to flanged vortex flow meters. The compact, space-saving design is versatile and can be installed in any location.
Products...
|
|
Rosemount/Rosemount Nuclear Transformer Connector 356
Introduction: Rosemount/Rosemount Nuclear Transformer Connectors 356 Rosemount 356 Nuclear Transformer Connectors are engineered to assemble the Rosemount 3152K Nuclear Transformer Pressure Transmitter to provide a reliable solution for harsh environments. This electrical conduit connector has a clamp-on disconnect design, which makes it easy to ...
|
|
Rosemount/Rosemount Sanitary Coriolis Meter H100S
Introduction: Rosemount Hygienic Coriolis Meter H100S, Coriolis Flow Meter made of 316L stainless steel, 3A/EHEDG certified, and finished up to 32Ra (0.8?m), is a hygienic application that requires high reliability, repeatability, and stable measurements.
|
|
Rosemount Hydrofluoric Acid Resistant pH Sensor 372 Range: 0—12pH
Description: The Rosemount/Rosemount Hydrofluoric Acid Resistant pH Sensor 372 uses a special glass formulation that greatly reduces the rate of HF corrosion, making it more cost-effective to measure HF solutions containing up to 1% (10,000 ppm).
Features:
After on-site inspection...
|
|
Rosemount/Rosemount Clamp-on Electromagnetic Flowmeter Sensor 8711060 4-200mm diameter
Description: The Rosemount/Rosemount clip-on electromagnetic flowmeter sensor 8711060 provides a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, dimensions and ...
|
|
Rosemount/Rosemount In-Line Oxygen Analyzer 6888C Communication Protocol 4-20mA
Introduction: The Rosemount/Rosemount In-Line Oxygen Analyzer 6888C, Rosemount 6888C In-Line Oxygen Analyzer provides continuous, accurate measurement of oxygen in flue gases in hazardous areas. Accurate measurement of the amount of residual oxygen is essential for the combustion reaction, reducing energy costs and improving safety.
|
|
Rosemount/Rosemount Electromagnetic Sensor MS300 Accuracy±0.25%
Introduction: The Rosemount/Rosemount electromagnetic sensor MS300, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high-solids fluids, long-fiber slurry, or installations that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Vortex Flow Meter 8800DR030 Diameter 15-300mm
Description: The Rosemount/Rosemount Vortex Flow Meter 8800DR030, an integrated diameter reduction gauge accurately measures low flow rates and maintains the same surface spacing as standard flanged vortex gauges.
Features:
Intelligent reducer design improves low flow measurement ...
|
|
Rosemount/Rosemount Multipoint Temperature & Level Sensor 765
Introduction: Rosemount/Rosemount Multipoint Temperature & Water Level Sensor 765, The Rosemount 765 is configured with an integrated water level sensor connected to a temperature sensor tube that measures the free water level at the bottom of the tank and correctly calculates the product volume. Rosemount multi-point temperature sensors use multi...
|
|
Rosemount/Rosemount replacement probe Oxymitter™ 4000 communication protocol 4-20mA
Introduction: The Rosemount/Rosemount replacement probe Oxymitter™ 4000, the Oxymitter 4000 in-situ oxygen transmitter is the world's first in-situ zirconia-based oxygen transmitter for flue gas measurement with an explosion-proof rating. These oxygen measurements can be used in control systems or operated by boilers.
|
|
Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341716
Description: The Rosemount/Rosemount Advanced Sonic Gas Ultrasonic Flow Meter USM341716 that leverages the power of a field-proven, United Kingdom-designed Rosemount four-channel string meter (OIML R137 1&2 accuracy class 0.5) designed by Towngas, combined with ...
|
|