Description: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381208, two-channel design, field-replaceable sensor, and highly accurate and repeatable measurements for verification metering, dispensing, leak detection, pipe balancing, process measurement, and other non-legal-for-trade applications.
Features:
Reduce sensitivity to flow profile, solids, and/or gas entrapment changes with ultra-fast Rosemount 3810 Series electronics
Use the integrated MeterLink™ software to monitor flow analysis and display a visual view of how the flow meter is working
Use predictive diagnostics and process variable information to detect problems and avoid process exceptions and fault downtime
Wear and tear on moving parts is avoided and maintenance time and costs are reduced
Use field-replaceable, non-wetted sensors for maintenance
Simplify design and installation by widening the flow range and enhancing bi-directional flow capabilities
Adopt the new Type 4 CPU module (with up to 6 frequency or digital outputs) to increase inputs/outputs
Product parameters
Linearity: ±0.3% of measured value over a range of 1.2 to 12.2 m/s (4 to 40 ft/s)
Repeatability: ±0.10% of measured value
Speed: 1.2 to 12.2 m/s (4 to 40 ft/s) nominal and 0.3 to 14.6 m/s (1 to 48 ft/s) extended
Operating temperature range:
Sensor: -50°C to +150°C (-58°F to +302°F), depending on material selection
Electronics: -40 to +60°C (-40 to +140°F)
Operating pressure range: 0 to 155 Bar (0 to 2250 psig)
Material: carbon steel and stainless steel
Calibration: Calibration is performed in an ISO 17025 accredited Emerson flow calibration laboratory
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the USM381220 products of Rosemount/Rosemount Liquid Ultrasonic Flow Meter, if you are interested in Rosemount/Rosemount Ultrasonic Gas Leak Detector, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381224
Introduction: The Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381224, two-channel design, field-replaceable sensor, high accuracy and repeatability of measurement results, suitable for verification metering, distribution, leak detection, pipeline balancing, process measurement, and other non-trade transactions.
|
|
Rosemount/Rosemount Conventional Manifold 304 90° Transmitter
Introduction: The Rosemount/Rosemount Conventional Manifold 304 is available in a combination of 2-, 3-, and 5-valve configurations and can be connected to the transmitter using conventional or collinar flanges. Available in conventional and clamp versions, the manifold is factory connected to the transmitter and leak tested, calibrated, and installed ...
|
|
Rosemount/Rosemount Level Transmitter 1408H 116 psi working pressure
Introduction: Rosemount/Rosemount Level Transmitter 1408H, Rosemount 1408H Level Transmitter provides accurate continuous level measurement. The radar is specifically designed to meet the hygienic requirements of the food and beverage industry. Hygienic approvals (3-A®, FDA, EC 1935/2004, ...)
|
|
Rosemount/Rosemount Quad Vortex Flow Meter 8800DQ100 has a turndown ratio of 15.1
Description: The Rosemount/Rosemount Quad Vortex Flow Meter 8800DQ100 with a fourth integrated transmitter for process control provides the ultimate redundant flow measurement solution to prevent false trips with a two-of-three vote. The 8800 Quad Vortex Flowmeter has an out...
|
|
Rosemount/Rosemount Retractable pH/ORP Sensor 396R
Introduction: Rosemount/Rosemount Retractable pH/ORP Sensor 396R, the Rosemount Model 396R sensor is designed for long life in harsh, dirty applications where a separate sampling flow path is difficult and large insertion depths are required. It is related to 1- ...
|
|
The Rosemount/Rosemount Transmitter 2090P has a 20:1 turndown ratio
Introduction: The Rosemount/Rosemount Transmitter 2090P Pulp & Paper Pressure Transmitter is ideal for the pulp and paper industry due to its compact size and rugged construction. This lightweight transmitter is available with a 1in. Flush mounting connections, or ...
|
|
Rosemount/Rosemount Explosion Proof Transmitter 5081 Power Supply 12VDC
Introduction: Rosemount/Rosemount Explosion Proof Transmitter 5081, the Rosemount 5081 Explosion Proof Transmitter is a single-channel loop-powered device that can receive pH/ORP sensors, conductivity sensors (contact and ring) sensors, and amperometers (dissolved oxygen, chlorine, and ozone sensors).
|
|
Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF060
Introduction: Rosemount/Rosemount Flanged Vortex Flow Meter 8800DF060
Features:
The isolated sensor design allows for in-tube replacement without breaking the process seal
The unique gasket-free gauge body design increases plant availability and ...
|
|
Rosemount In-Line Oxygen Analysis, Oxymitter™ 4000, protocol, 4-20mA
Introduction: The Rosemount/Rosemount In-Line Oxygen Analysis Oxymitter™ 4000 is the world's first in-line zirconia oxygen analysis transmitter for flue gas measurement, up to explosion-proof level. These oxygen content measurements are available ...
|
|
Rosemount/Rosemount Temperature Transmitter 648 LCD Display
Introduction: The Rosemount/Rosemount Temperature Transmitter 648 accurately measures internal process temperatures without the need for thermowelling or process perforation. Process temperatures can be safely recorded without cutting pipes and flow frequencies or process shutdowns can be calculated.
Features:
Provides excellent ...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381420 Pressure range 0 to 155 Bar
Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381420, a new custody transfer meter with excellent linearity over the flow range, further reducing product loss and unexplained loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Flanged Electromagnetic Flowmeter Sensor 8705025
Description: The Rosemount/Rosemount flanged electromagnetic flowmeter sensor 8705025 all-welded construction provides an airtight port for moisture and contaminant protection, while the junction box is removable and replaceable for easy field service.
Features:
In order to achieve maximum ...
|
|
Rosemount/Rosemount Signal Converter 333 HART® Tri-Loop™
Introduction: The Rosemount/Rosemount Signal Converter 333 HART® Tri-Loop™ provides easy access to up to three additional analog outputs. This signal converter converts a digital HART multivariable signal into three independent 4-20mA analog process variables without the need for additional ...
|
|
Rosemount/Rosemount Level Switch 2130 Vibrating Tuning Fork
Introduction: Rosemount/Rosemount Level Switch 2130, the Rosemount 2130 Level Switch was developed for challenging applications, harsh operating environments, and tight safety environments. The sturdy construction and built-in powerful diagnostics will keep you focused on your plant. Plug-and-play devices, meaning ...
|
|
Rosemount/Rosemount Level Transmitter 3302 Operating temperature -40—150°C
Description: The Rosemount/Rosemount Level Transmitter 3302 is used for level and interface measurements, providing a cost-effective and reliable solution for liquid applications. The Rosemount 3302 has no moving parts, requires no calibration, and is virtually unaffected by process conditions. With the help of the top ...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381410
Description: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381410, a new custody transfer meter with excellent linearity over the flow range to further reduce product loss and unidentified loss. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
Rosemount/Rosemount Vortex Flow Meter 8800DR140 with a turndown ratio of 38:01:00
Description: The Rosemount/Rosemount Vortex Flow Meter 8800DR140, an integrated diameter gauge that accurately measures lower flow rates and maintains the same surface spacing as standard flanged vortex gauges.
Features:
Intelligent reducer design improves low flow measurement ...
|
|
Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381208 Operating pressure range 0-155Bar
Introduction: The Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381208, two-channel design, field-replaceable sensor, high accuracy and repeatability of measurement results, suitable for verification metering, distribution, leak detection, pipeline balancing, process measurement, and other non-trade transactions.
|
|
The Rosemount/Rosemount Fixed Gas Detection Transmitter 925 outputs 4-20mA
Introduction: Rosemount/Rosemount Fixed Gas Detection Transmitter 925, Designed for use with the Rosemount 625 gas sensor, the Rosemount 925 Fixed Gas Detection Transmitter has received global certifications for the latest hazardous area and performance standards.
Features:
...
|
|
The Rosemount/Rosemount pressure transmitter 3051 Coplanar™ has a turndown ratio of up to 150:1
Introduction: Rosemount/Rosemount Pressure Transmitter 3051 Coplanar, the Rosemount 3051 Coplanar™ Pressure Transmitter offers business-leading performance and patented technology for added user convenience.
Features:
Rosemount 3051 ...
|
|