25. Bit status switch switch, bit status indicator, equipment linkage:
Through the bit state switching switch element OFF->ON, the macro command is executed: the bit status indicator is set to the ON state;
Select the execution macro through the PLC control, select ON->OFF as the trigger mode, and set the bit status indicator to OFF.
26. Button, watch hand, animation, multi-state indicator linkage control
Trigger macros with buttons to write values to addresses such as watch hands, animation positions, multi-state indicator states, and more.
27. The font is displayed in turn, and finally the whole is displayed
(1) In the animation element, add 5 states and 5 positions, execute macro instructions periodically, first write 0 to the state and position address, then use the delay function, delay 500ms, then write 1 to the state and position address, and then write 2 to the state and position address in the delay of 500ms; At a delay of 500ms, write 3 to the status and location address, and at 500ms, write 4 to the status and location address.
(2) In the animation symbol, add 5 states and 5 positions, add 2 multi-state setting components, and set the address to the state address and position address respectively, and select automatic increment (increase to the upper limit value), increment the value input 1, the upper limit value is 5, and the frequency is selected as 0,5 seconds.
28. Alarm display
First, add event login, select the status of the bit according to the question to set the alarm or the alarm through the upper limit of the value, enter the alarm content, and set the text.
It is necessary to scroll the alarm content and select the alarm bar element; It needs information such as event occurrence date, event occurrence time, event information, and number of occurrences, and selects the alarm display element; Information such as serial number, confirmation time, and return time is required to select an event display component.
29. Write the value by clicking the button and display it through the bar chart
If you set the same component address as the bar diagram component in the multi-state, select Increment/Decrement in the properties, and set the incremental/decrementing value and the upper value/lower limit value, you can increase or decrement the value by clicking this button.
In the bar diagram component, you can select the lower and upper limit values in the range according to the requirements of the problem, and set the corresponding upper and lower limit colors.
|
More on that
|
Veriton touch screen - precautions for using industrial tablet PCs
1. When turning on and off the power of the machine, it should be operated in strict accordance with the regulations;
2. According to the severity of the environment, set a time limit to open the machine head to clean the reflective stripes and inner surface of the touch screen;
3. At present, the mainstream industrial display program does not have a mouse cursor, because the flashing of the cursor will ...
|
|
How to add Siemens variables to the touch screen?
1. Create a new device driver: Enter the IP of the PLC.
2. Create a new PLC variable from Siemens.
3. Create a new button and download it to the touch screen.
|
|
How to insert the bit status indicator into the Weilun touch screen
Open the created Weilun touch screen project, select [Common] in the menu bar and click Open.
In the Common drop-down menu, select the Bit Status Indicator icon and click Open.
In the pop-up [New Bit Status Indicator] setting window [General Properties] ...
|
|
Velun Tong Touch Screen EBPro Software Knowledge Points (1-20)
1. Background color:
Right-click on the blank space of the window, select Properties, Pop-up Settings, and select a color in the background;
Hatch: In the background, tick the fill, select the pattern color and pattern.
2. Picture/Background Image:
Select Picture Element ...
|
|
How to set the touch screen not to standby?
1. Enter the system settings interface of the Weilun touch screen, and select the "Power Management" option in the "System Settings".
2. In "Power Management", you can set how long the touch screen will automatically enter the "standby" state without operation, and you can also set how long it will enter the "...
|
|
A detailed look at the seven different models of Veriton touch screens
Model 1, MT200, this model can be said to be the earliest model of this brand, which is very popular in some regions and can realize automated procedures.
Model two, MT500, this model is following the previous model, after the launch of the very good ...
|
|
Veriton touch screen - how to adjust the sensitivity of capacitive touch screen
Method 1: Reconfigure capacitive screen parameters through the configuration file
The configuration parameters of the capacitive touch screen are saved in the serial port screen, and the sensitivity of the capacitive touch screen can be configured by writing new parameters. For customers who need to add a panel to a capacitive touch screen, panel samples and structures can be ...
|
|
Veluntong Touch Screen EBPro Software Knowledge Points(30-34)
30. Button control indicator (same address)
Set the multi-state transfer switch element/bit state transfer switch element and the multi-state indicator element/bit status indicator element to the same address, click the multi-state transfer switch element/bit state transfer switch element, and the corresponding indicator ...
|
|
What are the symptoms of a faulty touchscreen motherboard?
1. The motherboard cannot recognize/display the peripheral devices.
2. The peripherals will stop working for a few seconds or more.
3. A slow boot may indicate that your motherboard is broken, although it could also be other components.
4. The touch screen does not recognize the flash drive, or ...
|
|
The steps of Weiluntong touch screen CMT to MT copy screen
1. Press the "Menu" button to enter the menu interface.
2. Select the "Picture" option to enter the screen settings interface.
3. In the screen settings interface, find the "Copy" option and press the "Enter" key to enter.
4. In the "Copy" option, select "Copy...
|
|
How to set the standby time on the touch screen
The default standby time is 1 minute. The specific steps are as follows:
1. First of all, open our touch screen editing software, and be sure to select the software corresponding to the touch screen model.
2. Edit the touch screen screen we need.
3. Open the common menu in the upper left corner ...
|
|
What is the reason why the touch screen cannot be turned on after restoring the factory settings?
1. Check that the power cord is plugged in and if there is electricity. If there is no electricity, you can replace the cord or plug.
2. Check if the power switch is on. If it doesn't turn on, you can try turning on the power switch.
3. Check if the battery is charged. If the battery is low ...
|
|
Weiluntong touch screen - introduction to the operation skills of touch screen
1. If you are using a capacitive touch screen, then it is recommended that you first install the driver required for the capacitive touch screen correctly according to the requirements of the manual when you use it for the first time, and then click "Start"/"Program"/"Microtouch Touc" on the screen with your fingers.
|
|
How does the Weilun Tong touch screen connect with the Omron NJ controller?
1. Omron NJ controller programming
1. The structure data type required for the new project, such as the Boolean switch to be used in this example to create a structure data type of "take-up machine IO", and the integer data used in this example to create a "take-up machine".
|
|
How to update the software of Velonton
1. Copy the required OS to a USB flash drive (FAT32 format is only supported); For example, in the next test, place the OS file in the firmware folder at the root of the USB flash drive.
2. Plug the USB flash drive into the USB host port of the HMI to be updated;
3. Click the arrow in the bottom right corner of the screen ...
|
|
Velun Tong - cMT1107X new product released
The cMT X series models are recognized and trusted by users for their excellent functions and stable performance. Therefore, after the launch of the standard and advanced cMT X series models, Weiluntong Technology has launched the cost-effective cMT X basic human-machine interface:
It can meet the needs of only a single network port and traditional ...
|
|
Key points for the selection of Weiluntong touch screen
1. Consider the size, how big the screen is, 7 inches or 10 inches, etc
2. Whether there is an Ethernet communication interface or a USB interface
3. Consider the type of interface supported by the touch screen, RS232/RS485 interface
4. Whether there is a general agreement, so that it can cooperate with different brands...
|
|
Weiluntong touch screen - what is a resistive touch screen
The three main types of Weiluntong touch screens are: resistive technology touch screen, surface acoustic wave technology touch screen, and capacitive technology touch screen. Each type of Veruntong touch screen has its own advantages and disadvantages, let's learn about resistive touch screens today!
The outer layer of the resistive screen is generally ...
|
|
How to change the description of the touch screen measurement point of Weiluntong
1. First of all, open the created Weilun touch screen project, select Common in the menu bar and click Open.
2. Secondly, select the system parameter icon in the common drop-down menu and click to open.
3. Finally, click Change.
...
|
|
Weincloud, bring you a different cloud experience | cMT X series
With the sudden changes in the market environment, the digital transformation of enterprises is imminent. In the process of digital transformation, cloud service integration is an important part. However, the high-level technical threshold and huge construction costs often discourage enterprises.
Therefore, Weiluntong Technology ...
|
|