FujiElectric ZPB Single Beam Infrared Gas Analyzer
peculiarity
High stability: zero drift±0.5%FS/week.
Mounted in a 19-inch cabinet, it weighs about 11kg, making it compact and lightweight.
Enables continuous measurement of the concentration of up to 5 gases.
Built-in magnetic oxygen analyzer or amperometric oxygen analyzer (optional).
Built-in air pressure disturbance compensation, RS-485 communication, automatic correction, alarm output, O2 conversion and other functions (optional).
The measuring parts are simple in structure and easy to maintain.
Main specifications:Measuring principle | NO, SO2, CO, CO2, CH4: Non-dispersive infrared absorption method (single beam)
O2: Electrochemical (built-in) or magnetic (built-in) or zirconia (ZFK7 type external) | Measurement composition and measuring range | NO:0~50ppm···5000ppm
SO2:0~50ppm···5000ppm
CO2:0~50ppm···25vol%
CO:0~50ppm···5000ppm
O2 (built-in electrochemical formula): 0~10vol%··· 25vol%
O2 (built-in magnetic type): 0~5vol%··· 100vol%
O2 (external zirconia type): 0~5vol%··· 25vol% | Measuring range | 1 component up to 2 ranges | repeatability | ± 0.5% FS or less | Linear | ± within 1% FS | Zero drift | ± 0.5% FS/week | Full-scale drift | ±2% FS/week | Response time (within 90%) | Within 30 seconds (Consumption time varies depending on the gas switching time) | Analog output signal | DC4~20mA or DC0~1V | Measured values are displayed | LCD with backlight (Japanese, English or Chinese: as specified)
Instantaneous values of each component, O2 to instantaneous values, O2 to average values, O2 to average values | Spanning switching | Manual and automatic range switching is possible by pressing a button, and remote switching is possible with external contact input (optional). | External contact input (optional) | Voltage input contact (supply voltage DC12~24V, maximum current 15mA)
Remote range switching, auto-correction remote start, remote output hold, average value reset | Contact output (optional) | 1c relay contact (contact capacity DC24V/1A resistive load)
Instrument abnormality, correction abnormality, range identification, automatic calibration, automatic correction is driven by solenoid valve,
Upper and lower limit alarms, CO concentration peak alarms | Barometric Disturbance Compensation (Optional) | Built-in as specified | Standard features | Output signal holds, manual/automatic range switching | Optional features | Auto-Calibration, Auto-Calibration Remote Start, Remote Output Hold, Range Identification Contact Output,
Upper and lower limit alarm output, O2 conversion value output, O2 conversion average value output, average value reset contact output,
CO concentration peak alarm contact output | Communication function (optional) | RS-485 (Modbus) (9-pin D-sub output) Half-duplex serial, synchronous start and stop | Gas flow monitor under test | Yes | Size of gas inlet and outlet | Rc1/4 or NPT1/4 female | Purge gas flow | 1L/min (as required) | Reference gas | Required (Dry N2 or Dry Air) | Ambient temperature and humidity | -20~60°C 90% or less (no condensation) | Supply voltage | AC100V~240V 50/60Hz | Rated power | Approx. 100VA | Dimensions | 133(H)×483(W)×382(D)mm | weight | Approx. 10kg | Applicable certifications | CE marked | The condition of the gas being measured | flow rate | 1.0L / min±0.2L / min | temperature | 0 ~ 50℃ | pressure | 10kPa or less | dust | Particles below 0.3 μm: 100 μg/Nm3 or less | Aerosol | not | moisture content | Saturation cannot exceed 2°C (the same as the measured gas and the reference gas) | Corrosive components | HCL 1ppm or less |
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow!
In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
FujiElectric UG30 Series POD
Introduction: FujiElectric UG30 series POD
Product Introduction
■Features
●Compatible with 32,768 color displays
It can handle 32,768 color displays, and the display effect is the same as that of photos.
●AV functions are substantial
Video input ...
|
|
FujiElectric ZPG Single Beam Infrared Gas Analyzer
FujiElectric ZPG Single Beam Infrared Gas Analyzer
peculiarity
High stability: zero drift±0.5%FS/week.
Installed in a 19-inch cabinet, it weighs about 9kg, making it compact and lightweight.
Enables continuous measurement of low gas concentrations.
...
|
|
FujiElectric V9060iT Human Machine Interface (HMI)
Introduction: FujiElectric V9060iT HMI 15.1-inch, TFT, 64K color, 3-ch serial, CF, A·· B USB, communication I/F built-in, XGA
Product Picture Show:
Specifications:
The above ...
|
|
FujiElectric V9080iS Human Machine Interface (HMI)
Introduction: FujiElectric V9080iS HMI 8.4-inch, TFT, 16.7M color, SVGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZKM zirconia gas analyzer
Introduction: FujiElectric ZKM zirconia gas analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
4~7 seconds of rapid ringing ...
|
|
FujiElectric PHC type 6 color inkjet recorder
Introduction: FujiElectric PHC type 6 color inkjet recorder, inkjet method 100mm paper width recorder, clear recording, thermocouple, temperature measurement resistance, voltage/current signal as input
Product Picture Show:
Main features of the product:
...
|
|
FujiElectric V9100iC Human Machine Interface (HMI)
Introduction: FujiElectric V9100iC Human Machine Interface (HMI) 10.4 inches, TFT, 16.7M color, XGA, 3ch serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZRE Infrared Gas Analyzer
FujiElectric ZRE Infrared Gas Analyzer
peculiarity
It adopts a single beam type, which is compact and easy to maintain.
Excellent long-term stability.
The large LCD screen is used to make it clearer and more eye-catching, and easy to operate.
...
|
|
FujiElectric ZEME Pressure-Resistant and Explosion-proof Gas Analyzer
Introduction: FujiElectric ZKME Pressure-Resistant and Explosion-proof Gas Analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds ...
|
|
FujiElectric PPU large paperless recorder
Introduction: FujiElectric PPU Large Paperless Recorder, 300×300mm Front Size Up to 36 points can be recorded for up to 12 types of thermocouples, 2 types of temperature resistors, and voltage/current input signals.
Product Picture Show:
...
|
|
FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
Introduction: FujiElectric ZFKE Pressure-Resistant and Explosion-proof Gas Analyzer
peculiarity
Zirconia sensors can be replaced and maintenance is simple.
Fast response speed of 4~7 seconds, which can be used for combustion control.
It is possible to open the case without opening the shell.
|
|
FujiElectric PHA inkjet recorder
Introduction: FujiElectric PHA inkjet recorder is a 180mm paper width recorder with 6 colors of inkjet, vivid recording, and inkjet method. Thermocouples, temperature resistors, and voltage/current signals are used as inputs
Product Picture Show:
Key Specifications:
...
|
|
FujiElectric V9150iX Human Machine Interface (HMI)
Introduction: FujiElectric V9150iX Human Machine Interface (HMI) 15-inch, TFT, 16.7M Color, XGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F, LAN 1ch, Audio
Product Picture Show:
Specifications:
...
|
|
FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI)
Introduction: FujiElectric/Fuji TS1070S/TS1100S Human Machine Interface (HMI) supports remote operation through VNC server function, and supports various specifications as standard, and the FROM capacity has been greatly expanded by 2.2 times.
Product Picture Show:
Specifications:
...
|
|
FujiElectric ZAF Thermal Conductivity Gas Analyzer
FujiElectric ZAF Thermal Conductivity Gas Analyzer
peculiarity
Large, easy-to-see LCD display.
Can communicate with a computer.
Compact panel mounting structure.
Automatic correction function for zero point and full-scale point (optional)
|
|
FujiElectric ZKG Magnetic Oxygen Analyzer
FujiElectric ZKG Magnetic Oxygen Analyzer
peculiarity
Magnetic method (pressure detection type) eliminates the need for auxiliary gases.
The detection part does not have heating parts such as heaters, and is suitable for oxygen measurement in flammable gases.
Almost unaffected by other ...
|
|
FujiElectric FWD Air Ultrasonic Flow Meter
FujiElectric FWD Air Ultrasonic Flow Meter
peculiarity
Suitable for a variety of pipe diameters to meet your needs.
Suitable for diameter 25mm~200mm.
There is no pressure loss, and zero energy loss is realized.
This product adopts ultra...
|
|
FujiElectric V9071iW Human Machine Interface (HMI)
Introduction: FujiElectric V9071iW Human Machine Interface (HMI) 7-inch, TFT, 16.7M Color, WVGA, 3ch Serial, SD I/F, A/mini B USB, COM I/F
Product Picture Show:
Specifications:
The above introduction ...
|
|
FujiElectric ZKJ Infrared Gas Analyzer
FujiElectric ZKJ Infrared Gas Analyzer
peculiarity
It is suitable for measuring the concentration of NOx, SO2, CO, CO2, CH4, and O2 gases in incinerators, combustion exhaust gases, and various industrial furnaces
Up to 5 components of the gas concentration can be continuously ...
|
|
FujiElectric ZSS in-line laser gas analyzer
FujiElectric ZSS in-line laser gas analyzer
peculiarity
Analyzer for HCL, NH3, O2, CO, CO2, CH4 gas concentration measurement.
Due to the fast response speed (less than 1~5 seconds), it can be assembled into the control system.
|
|