Introduction: Meanwell/Meanwell-HDRP-480 single-group output rail type industrial power supply, built-in PFC correction function, working frequency 100KHz, working temperature, humidity -10°C~+70°C; 20%~90 %RH non-condensing
Product Picture Show:
Features:
Built-in PFC correction function, PF>0.95Protection Characteristics: Short Circuit/Overload/Overvoltage/High Temperature,air cooling,DIN rail TS-35/7.5 or 15 can be installed,With power-on display (light-emitting diode),100% full load burn-in test,Operating frequency 100KHz,One-year shelf life,Size:227*125.2*100mm(W*H*D)
Product Model Introduction:
| | | | | | | | | | | | | | | | | | | | | | DC voltage adjustable range | | | | 1200ms, 40ms/220VAC full load | | | | | 180~264VAC, 47~63 Hz or 250~370VDC | | | | |
| | | | | | | Protection characteristics | | 105%~150% of rated output power | Protection mode: constant current limit, automatic recovery after the load abnormal condition is removed | | | | Protected mode: Turn off the output voltage and resume after restarting | Over-temperature protection | 100°C±5°C (TSW1) heat sink for detecting power transistors | Protection mode: Turn off the output voltage, and automatically recover when the temperature returns to normal | | Operating temperature, humidity | -10℃~+70℃; 20%~90 %RH non-condensing (please refer to load derating curve) | Store at temperature and humidity | | | 10~500Hz, 2G 10min./1 cycle, 60 minutes each in X, Y, and Z axes; Installation: Complies with IEC60068-2-6 | | | Input and output room: 3KVAC Input and ground: 1.5KVAC Output and ground: 0.5KVAC | | Input/output room, input and ground, output and ground: 100M Ohms / 500VDC | | | UL508, UL60950-1, TUV EN60950-1 compliant | | EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2) | | | | | 6pcs/15kg/1.75 cubic meters | | 1. All parameters are measured at 230VAC input, rated load and 25°C unless otherwise specified.
2. Ripple and noise voltages are measured at a 20MHz bandwidth oscilloscope with 12-inch twisted pair ends plus 0.1μ and 47μ capacitors.
3. Tolerance is the sum of voltage setting error, voltage regulation, and current regulation.
4. This power supply is considered to be installed as a device on the final device, which must reconfirm its EMC specifications.
5. The specific output current is shown in the output derating curve. |
Shape and installation dimensions:
The above is the product Meanwell/Meanwell-HDRP-480 single group output rail type industrial power supply, mainly to understand the main features, models, and installation dimensions of the product. We uphold the integrity of life, sincere service attitude, if you are interested in Yaskawa servo drive, please also contact our sales staff, we look forward to your call, hope our technology and service to bring you a good experience.
Our aim: to survive by quality, to develop by reputation, to serve eternity, to give us a chance, but also to give you a surprise.
|
More on that
|
Meanwell-HDR-75 DIN rail switching power supply
Introduction: Meanwell/Meanwell-HDR-75 DIN rail switching power supply, DIN standard rail TS-35/7.5 or 15 can be installed, working frequency 50KHz, weight 0.6Kg, impulse current: cold start current 20A/115V 40A/230V
Product Picture Show:
Product Features ...
|
|
MEAN WELL/Meanwell_HPS-65 single output switching power supply_100% full load burn-in test
HPS-65 Introduction: AC input current 1.2A/115VAC0.72A/230VAC, impulse current, cold start current 20A/115VAC40A/230VAC, working frequency 65KHz, features: global AC input power supply, protection features: short circuit/overload/overvoltage, air cooling, low leakage current ...
|
|
Meanwell Power RSP-2400-12 has a rated power of 2000.4W
Introduction: Meanwell/Meanwell Power RSP-2400-12, RSP-2400 is a 2.4KW single output enclosure type AC transformer-DC power supply.
Features:
AC input range 180-264VAC
Built-in active PFC function,
Efficiency up to 91.5%
...
|
|
Meanwell/Meanwell-HDRP-240 single-group output rail type industrial power supply
Introduction: Meanwell/Meanwell-HDRP-240 single output rail type industrial power supply, built-in PFC correction function, PF>0.95, working frequency 100KHz, overvoltage protection, 30~36V
Product image display
Features:
Worldwide AC input ...
|
|
MEAN WELL/Meanwell_HDR-60 DIN Rail Switching Power Supply_Leakage Current<1mA/240VAC
HDR-60 Introduction: Can be installed with DIN standard rail TS-35/7.5 or 15, with power on display (LED emitting diode), air cooling, insulation class II., 100% full load burn-in test, features: AC input power supply for worldwide, protection characteristics: short circuit/overload/overvoltage.
...
|
|
Taiwan Meanwell/Meanwell DIN rail type power supply HDR-60-48 rated current 1.25A
Introduction: Taiwan Meanwell/Meanwell DIN rail type power supply HDR-60-48, HDR-60 is an economical ultra-thin type 60W DIN rail type power supply in line with Germany industrial standards, suitable for installation on TS-35/7.5 or TS-35/15 rails, in the allow space saving cabinet body is designed to 52. ...
|
|
MEAN WELL/Meanwell_HDR-30 DIN rail switching power supply
HDR-30 Introduction: MeanwellHDR-30 DIN Rail Switching Power Supply, with Power on Display (LED Flash), DIN Standard Rail TS-35/7.5 or 15 can be installed, Insulation Class II. Features: Worldwide AC input power supply. Protection characteristics: short circuit/overload/overvoltage
...
|
|
HDR-120 DIN Rail Switching Power Supply
HDR-120 Introduction: Start-up, Rise Time 500ms, 70ms/230VAC Full Load 500ms, 70ms/115VAC Full Load, Holding Time 36ms/230VAC32ms/115VAC Full Load, DIN Standard Rail TS-35/7.5 or 15 can be installed. Features: Worldwide applicable AC input power supply, protection characteristics: short ...
|
|
MEAN WELL/Meanwell_HDR-45 DIN Rail Power Supply_DIN Standard Rail TS-35/7.5 or 15 can be installed
HDR-45 Introduction: Meanwell/Meanwell DIN rail switching power supply, can be installed with DIN standard rail TS-35/7.5 or 15, with boot display (LED emitting led), 100% full load burn-in test, working frequency 100KHz. Features: Worldwide AC input power supply. Protection Characteristics: Short Circuit/...
|
|