Delixi CDF1 isolation switch introduction and the difference with the transfer switch Delixi CDF1 isolation switch introduction and the difference with the transfer switch

Delixi CDF1 load isolation switch, the product material is carefully selected, with the advantages of reliability and durability. At the same time, it is locked when the power is on, and it can only be turned on when the power is off, which effectively avoids the occurrence of electric shock accidents. The contacts are made of high-quality copper ...

Delixi Electric rushed to the front line of the anti-epidemic in various places Delixi Electric rushed to the front line of the anti-epidemic in various places

On March 12, Delixi Electric partner Qingdao Hengtong Ruide received an order, continued to deploy a batch of components to be shipped to Laixi cabin hospital, Delixi Electric strategic cooperation plant Qingdao Fengtai Electric overnight deployment, 24 hours smoothly completed handover, escort for Qingdao war epidemic. ...

CDQ1F series PC-level excitation automatic transfer switch - Delixi CDQ1F series PC-level excitation automatic transfer switch - Delixi

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

Delixi inverter application case Delixi inverter application case

The traditional textile printing and dyeing industry is a labor-intensive industry, and the degree of automation is not high. Most of the transmissions used are not speed regulation, and most of the occasions that need speed regulation are DC motors, such as warping machines, sizing machines and many printing and dyeing equipment.

Delixi Electric CDW3 universal circuit breaker introduction Delixi Electric CDW3 universal circuit breaker introduction

The CDW3 series frame circuit breakers are rated from 400A to 6300A and 415V/690V AC for extreme environmental conditions of 50 Hz AC and -40°C to 70°C. It is mainly used in the distribution network, distributing electric energy, protecting lines and power supply equipment from ...

Inverter maintenance technology - Delixi inverter Inverter maintenance technology - Delixi inverter

(1) Fault characteristics a) *** tripping may occur during operation, but if it is restarted after resetting, it often trips as soon as the speed rises. b) has a large inrush current, but most drives can already be tripped, maintenance without damage. Due to the ...

Delixi circuit breaker model difference Delixi circuit breaker model difference

CDB1 miniature circuit breaker is a kind of current-limiting high-breaking miniature circuit breaker with double protection of overload and short circuit, which is suitable for AC 50Hz, rated voltage 400V and below, rated current 63A and below circuits, as line overload and short circuit protection, can also be used under normal circumstances.

Delixi Electric universal switching power supply Delixi Electric universal switching power supply

Delixi general switching power supply can provide stable DC output products, widely used in communications, LED displays, industrial control, radio and television, computer networks, medical equipment, intelligent monitoring and other fields. Delixi universal switching power supply SA, DA, TA, QA Type 85 - 132 / ...

Delixi inverter Delixi inverter

Delixi inverter has launched CDI9000 series inverter, CDI9100 series inverter, CDI9100-S series inverter, CDI9200-G series general-purpose inverter, CDI9200-P series fan pump inverter, CDI9200-ZS series injection molding machine special inverter, CDI9200-GS series ...

The reason for the instability of the voltage regulator output - Delixi The reason for the instability of the voltage regulator output - Delixi

It shows that the voltage regulator base is not voltage corrected, and the voltage regulator in this situation is like a transformer, the higher the input voltage, the higher the output voltage, the input decreases and the output voltage also decreases. This...

Delixi inverter controller data instability solution Delixi inverter controller data instability solution

Problem depiction: The data of Delixi inverter controller is unstable, and sometimes there is a deviation, how to deal with it? Solution: This is the result of severe disturbance of the controller. Often the controller ...

How about Delixi switch? How about Delixi switch?

Delixi focuses on the development of green energy-saving industry, the construction of LED ecological industrial chain. It has established an industrial development format with Shanghai as the research and development center and Hangzhou and Jiaxing as the production base of LED lighting products, specializing in the development, production and sales of LED fluorescent lamps, three-proof lamps, downlights, spotlights, street lamps and other high-tech products.

Delixi inverter fault maintenance Delixi inverter fault maintenance

Delixi inverter is a commonly used inverter, how to maintain in the event of failure?   Constant speed overcurrent: When the inverter is running at a constant speed, the output current exceeds the current value. Check whether the output circuit of the inverter is short-circuited. Check if the input voltage is low. Examine...

Delixi circuit breaker common model features Delixi circuit breaker common model features

CDB1 miniature circuit breaker is a current-limiting high-breaking miniature circuit breaker with overload and short-circuit maintenance, which is suitable for communication 50Hz, additional voltage 400V and below, additional current 63A and below circuits, as line overload and short circuit maintenance, can also be used under normal circumstances.

Confession of Delixi inverter "energy-saving pioneer". Confession of Delixi inverter "energy-saving pioneer".

  My name is Inverter, and among the many new energy-saving products, I am known as the "energy-saving forward" for my excellent function. In today's world, extreme disasters occur frequently, with melting glaciers, rising sea levels, persistent droughts, and heavy rainfall.

Prevent damage to the inverter - Delixi inverter Prevent damage to the inverter - Delixi inverter

1. Check and tighten all terminals to prevent serious heating caused by loosening. 2. Conduct a comprehensive view of the input (including output) terminal, rectifier module, inverter module, DC capacitor and fast-melting devices, and the parameters ...

How to wire and use the number of switches when the inverter starts and stops - Delixi How to wire and use the number of switches when the inverter starts and stops - Delixi

The control of the inverter is nothing more than the fundamental logic of starting, aborting, forward rotation, rotation, and speed regulation, which fundamentally requires that the level condition is effective, rather than the rising edge is effective, so the use of button switches to control the inverter is generally required to use the self-protection of the button...

Delixi molded case circuit breaker external two tripping wire connection Delixi molded case circuit breaker external two tripping wire connection

The molded case circuit breaker tripper is divided into undervoltage tripper and shunt tripper. This article explains the wiring method of the circuit breaker with sub-excitation tripper. The shunt tripper is often used as an additional accessory for the user, it is a remotely operated circuit breaker disconnection device, installed in the molded case circuit breaker, when the shunt ...

Delixi leakage protector tripping causes and solutions Delixi leakage protector tripping causes and solutions

1. The leakage protector does not match the load. This situation mostly occurs when using high-power electrical appliances, and it is generally only necessary to replace the leakage protector that matches the practical needs from scratch. 2. Check whether the switch wiring is correct, ...

Delixi inverter selection points Delixi inverter selection points

Variable-frequency Drive (VFD) is an electric power control equipment that uses frequency conversion skills and microelectronics skills to control and communicate motors by changing the frequency of the working power supply of the motor. The inverter is mainly composed of rectifier (communication to DC), filtering, inverter (DC to ditch) ...

Delixi brought EasyPro series solutions to the fair Delixi brought EasyPro series solutions to the fair

Shanghai, September 19, 2018 ---- Today, the 20th China International Industry Fair (hereinafter referred to as the "Industry Fair") officially kicked off in Shanghai. From the perspective of a new breakthrough in the integration of manufacturing and the Internet, this year's industry fair focused on showing the scientific and technological innovation of China's manufacturing profession.

Next Page »
12345678910Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top