Introduction: E+H/Endershaus Capacitive Level Measurement Liquicap FMI52, the reliable, fully insulated probe of Liquicap FMI52 is ideal for continuous measurement of liquid levels, especially in small storage tanks, in media with adhesion formation, and in extremely high temperatures. The measurement is independent of the DK value (dielectric constant). Paired with the Fieldgate FXA320, remote measurement access using Internet technology, Liquicap offers the ideal inventory management solution.
Features:
For liquids with conductivity greater than 100μS/cm, no calibration is required, and the probe length is 0%/100% preset at the factory, making commissioning quick and easy.
Text display, menu-guided on-site setup (optional).
It has obtained various certifications and licenses, and has a wide range of applications.
IEC 61508 compliant for safety systems requiring SIL2 safety.
The wetted part is made of corrosion-resistant materials and FDA-approved materials.
Double overvoltage protection (gas discharger + protective diode) prevents tank discharge.
Electronic components provide built-in adhesion compensation
Product parameters
Measuring principle
Capacitance level meter
Features/Applications:
Fully insulated rod probe for standard and severe working conditions (temperature, pressure)
Interface measurements
Liquid/liquid interface with emulsion layer
peculiarity
Length of shield segment
Factory calibration
Short response time
Power/Communications
12…36 DC HART
PFM
Measurement accuracy
Repeatability of 0.1%
Linearity error in the measurement of conductive liquids
<0.25%
Ambient temperature
-50…+70°C
-58…+158°F
Process temperature
-80…200°C
-112…392°F
Process pressure (absolute)/maximum overpressure limit
Vacuum... 100 bar
(Vacuum...) 1450 psi)
The main wetted parts
Insulation material: FEP, PFA
316L
Process connections
G 3/4、G 1、G1 1/2 /NPT 3/4"、NPT 1、NPT1 1/2"
Minimum flange diameter DN25.../ASME 1".../JIS...
Hygienic process connections
Tri-Clamp ISO02852 clamp with no backlash
Milk connectors
Flush mounting
Sensor length
Overall Length: 6m (20ft)
Shield section length: up to 2m (7ft)
Maximum measuring distance
0.42…10.0 m
(1.38…33 ft)
correspondence
4…20mA HART
PFM
Certificates and certifications
ATEX、FM、CSA、IEC Ex、TIIS、INMETRO、NEPSI
Security certifications
Spill protection WHG
SIL
Design Certification
EN 10204-3.1
NACE MR0175
Hygienic approval
EHEDG
Class Certification
GL/ ABS
Options
Detachable housing
Hermetic probe seals
Apply restrictions
Varied, non-conductive medium, conductivity < 100 μS/cm
Pay attention to the pressure and temperature decrease
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the E+H/Endershaus Capacitive Level Measurement Liquicap FMI52 product, if you are interested in temperature transmitters, please also contact our staff, we look forward to your call, we hope our technology and service can bring you a better experience
|
More on that
|
E+H/Endershaus Modular thermocouple thermometer TC15
Introduction: The E+H/Endershaus Modular Thermocouple Thermometer TC15 is a highly modular, rugged thermometer for almost all industry applications. Compatible with all common communication protocols, the head-mounted transmitter is ready-to-use, with enhanced ...
|
|
E+H/Endershaus thermometer MultiSens Slim iTHERM TMS21
Description: The E+H/Endershaus thermometer MultiSens Slim iTHERM TMS21 is designed for use in applications that require a small size and light weight. The TMS21 adopts a modular design that flexibly meets the user's customized requirements. Only one process connection is needed to monitor the entire ...
|
|
E+H/Endershaus Radiometric Level and Density Measurement Gammapilot FMG50
Introduction: E+H/Endershaus Radioactive Level and Density Measurement Gammapilot FMG50, the Gammapilot FMG50 all-in-one transmitter enables non-contact point level detection, continuous level measurement, interface measurement and density measurement in liquids, solids, suspensions or sludge.
...
|
|
E+H/Endershaus Ultrasonic Flow Meter Proline Prosonic Flow 93W
Description: The E+H/Endershaus Ultrasonic Flow 93W ultrasonic flow meter offers a wide range of outputs for optimal measurement performance with automatic frequency sweeping.
Features:
Low investment costs – the larger the pipe diameter (up to DN 400 ...
|
|
E+H/Endershaus sensor Memosens CLS82E sensor Pt1000
Description: E+H/Endershaus sensor Memosens CLS82E, Memosens CLS82E is a high-end hygienic sensor for applications with a wide conductivity range.
Features:
Hygienic design, certified materials, EHEDG tested, 3-A and FDA recognized...
|
|
E+H/Endershaus temperature transmitter iTEMP® TMT84
Introduction: The E+H/Endershaus temperature transmitter iTEMP® TMT84 offers excellent reliability, accuracy and long-term stability for critical processes in all industries, not only for the transmission of thermoresistive (RTD) and thermocouple (TC) digital conversion signals, but also for the use of PRO ...
|
|
E+H/Endershaus Modular RTD Thermometer TR10
Introduction: The E+H/Endershaus modular RTD thermometer TR10 is a highly modular, rugged thermometer for almost all industry applications. Compatible with all common communication protocols, the head-mounted transmitter is ready-to-use, with enhanced ...
|
|
E+H/Endershaus hydrostatic level gauge Deltapilot FMB52 with a turndown ratio of 1001
Description: E+H/Endershaus Hydrostatic Level Gauge Deltapilot FMB52, Deltapilot FMB52 cable sensor with CONTITE measuring cell with fixed process connection, mainly used in the process and environmental protection industries, for measuring liquids or slurries in open or closed containers...
|
|
E+H/Endershaus Travel Time Radar Measurement Micropilot FMR20
Introduction: E+H/Endershaus Travel-time radar measurement Micropilot FMR20, Micropilot FMR20 for continuous, non-contact level and flow measurement (via linearized tables), is particularly suitable for use in the water and wastewater industry, as well as for utilities in various industries. It can be done by HART...
|
|
E+H/Endershaus Universal Dissolved Oxygen Measurement Transmitter Liquisys COM253
Description: The E+H/Endershaus universal dissolved oxygen measurement transmitter Liquisys COM253, the Liquisys COM253 standard transmitter can be used with the COS41 and COS61 dissolved oxygen measurement sensors.
Features:
Increased operational safety: Continuous process checks ...
|
|
E+H/Endershaus color sensor OUSAF22 IP65 degree of protection
Introduction: E+H/Endershaus Colorimetric sensors OUSAF22, OUSAF22 optical sensors, are used for color measurement in the visible region of the electromagnetic spectrum.
Features:
Accurate color and purity monitoring ensures better product quality
Fast...
|
|
E+H/Endershaus Radar measures travel time principle Micropilot FMR54
Introduction:E+H/Endershaus Radar Measurement Travel Time Principle Micropilot FMR54, Micropilot FMR54 is mainly used for liquid level measurement in high temperature and high pressure occasions, and its specially designed flat panel antenna is especially suitable for liquid level measurement with waveguide installation.
Features:
...
|
|
E+H/Endershaus Mass Flow Meter Proline Promass I 300 Measuring Tube 904L
Description: The E+H/Endershaus mass flow meter Proline Promass I 300 is designed with a single straight tube to measure mass flow, density and temperature at the same time as in-line viscosity measurements. The Promass I 300 is equipped with an all-in-one transmitter that offers excellent operation and system integration.
|
|
E+H/Endershaus temperature transmitter iTEMP® TMT180
Description: The E+H/Endershaus temperature transmitter iTEMP® TMT180 is designed for signal transmission in RTD Pt100 sensors and can be set with different measurement ranges. 4 ... A standard current output signal of 20 mA is used for process measurements. It can be used in all kinds of non-explosion-proof areas, providing ...
|
|
E+H Proline Promass G100 Liquid error ±.10%
Description: The E+H/Endershaus mass flow meter Proline Promass G 100 enables safe and precise measurement of liquids and gases in high-pressure applications with pressures up to 350 bar (5080 psi). Simple and safe safety with safety diaphragm and threaded process connections.
|
|
E+H/Endershaus Tuning fork level switch Soliphant FTM21
Introduction: E+H/Endershaus Tuning fork level switch Soliphant FTM21, Soliphant FTM21 limit switch is suitable for non-flowing solid fine and coarse material level detection.
Features:
No calibration required: Simple commissioning (plug and play)
Anti-adhesion and maintenance-free
...
|
|
E+H/Endershaus temperature transmitter iTEMP TMT72
Introduction: The E+H/Endershaus temperature transmitter iTEMP TMT72 is designed for high reliability, measurement accuracy and long-term stability in critical process sections in all industries. The transmitter is configurable and communicates via HART® to receive not only RTDs and thermocouples, but also thermocouples.
|
|
E+H/Endershaus Bar Protective Sleeve TA562 Maximum insertion depth 5 mm
Introduction: E+H/Endershaus Bar Protective Sleeve TA562, because of the harsh process conditions, the strength of the protective sleeve must be precisely calculated. Dyeing penetration test, ultrasonic test, helium leak test, pressure durability test, and various non-destructive material tests to prove the material and workmanship.
|
|
E+H/Endershaus Electronic differential pressure transmitter Deltabar FMD72 process pressure 160 bar
Description: E+H/Endershaus Electronic differential pressure transmitter Deltabar FMD72 electronic differential pressure measuring system is used to measure the pressure, level, volume or mass of liquids in pressure vessels or distillation columns/evaporators. The high-pressure side sensor (HP) measures the hydrostatic pressure of the liquid, and the low-pressure side sensor (LP) ...
|
|
E+H/Endershaus Ultrasonic Measurement of Travel Time Principle Prosonic FDU93
Introduction: E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FDU93, the FDU93 ultrasonic sensor is suitable for continuous, non-contact level measurement of liquids, slurries, sludges, powders and solid lumps, maintenance-free, and can also be used for flow measurement in open channels and measuring weirs ...
|
|