The driving principle of a capacitive touch screen

Create Date: 2024-8-30 12:03:23|Source: Hitec/HITECH

1. Projective capacitive contacts

Although the basic structure and working principle of the projected capacitive contact screen is the same as that of the four-wire impedance film, the projected capacitive impedance film does not pass through the contact field, but captures the change of capacitance between the electrodes. Generally speaking, when using a capacitive sensor form, it can almost be called a secondary extension of the contact switch. About contact switches.

The projection capacitance form does not require electrode deformation like the impedance film type, and can be detected from the surface of the contact plate up to 10 mm. In addition, the surface of the panel is covered with glass scars, and it has excellent durability and environmental resistance, but there is no change in capacitance, and the contact panel of the insulator does not work, so it cannot be operated when touched with gloves.

  ​                   The driving principle of a capacitive touch screen

2. Surface capacitance contact

The surface capacitance method is the same as the projection capacitance method. Induce a change in capacitance. When the projection capacitance method is considered to be the four-wire resistance film method, the surface capacitance method is equal to the five-wire resistance film method, and the fifth line is the human body. It is composed of a transparent conductive film and electrodes at four corners. During operation, the electrodes at the four corners are applied the same voltage, and the panels form uniform electrical boundaries.

When all are in phase, the capacitors on the panel are discharged. Activity. On the other hand, when a finger touches the contact screen, the capacitor becomes grounded. The current moves from the corners through the fingers, and the current value of the electrodes closer to the contact part increases. At this moment, only the amount of electricity coming from the four corners is measured. This ratio can be used to determine a specific part.

More on that
The internal composition of the touch screen - Hitec The internal composition of the touch screen - Hitec

The interior of the touch screen can be roughly divided into: communication interface unit, driver unit, memory variable unit, and display unit. In addition to the display unit, the other 3 units are invisible to us inside the touch screen. 1. Communication interface ...

Touch screen touch unresponsive fault analysis and processing - Hitech Touch screen touch unresponsive fault analysis and processing - Hitech

Correct equipment, operation and maintenance of reducer is an important part of ensuring the normal operation of mechanical equipment. Therefore, in your device, first check whether the wiring interface is loose, and then check whether the serial port and interrupt number are conflicting, if there is resistance, you should adjust the resources to avoid resistance. Look again ...

The reason for the decrease in the click accuracy of the Hitec touch screen The reason for the decrease in the click accuracy of the Hitec touch screen

Fault phenomenon Hitec contact screen, its click accuracy decreases, and the cursor is difficult to locate. Fault profiling processing 1) Run the Hitec Touch Screen Calibration Program. (Beginning--Settings--Control Panel--Sonic Screen---Cal...

The PLC and touch screen interact consistently The PLC and touch screen interact consistently

When the touch screen is connected with the PLC, in fact, the memory of the PLC is used, (the touch screen also has a small amount of memory, which is only used to store system data, that is, the screen, controls, etc.), the touch screen and the PLC communication is generally the master/slave contact, that is, the touch screen reads the data from the PLC, and the judgment is made in the display ...

How to choose the touch screen of industrial display - Hitec How to choose the touch screen of industrial display - Hitec

1. Four-wire resistive touch screen: It is not afraid of dust, oil and photoelectric disturbance, and is afraid of scratches is its main defect. It is suitable for public places with fixed users, such as industrial control sites, offices, homes, etc.; 2. Five-wire resistive touch screen: Excellent sensitivity and transmittance ...

Industrial touch screen touch solves the problem of unresponsiveness Industrial touch screen touch solves the problem of unresponsiveness

Many people have encountered industrial contact screen contact no response, no matter how we point to the industrial contact screen is not responding, at this time many people don't know what to do, today let's take a look at what to do when encountering industrial contact screen contact no response. ...

Introduction to common sense of human-machine interface - Hitec touch screen Introduction to common sense of human-machine interface - Hitec touch screen

1. What is the difference between the human-machine interface and the "touch screen" that people often say? Strictly speaking, the two are fundamentally different. Since the "touch screen" is only a hardware part that may be used in human-machine interface products, it is a replacement for the mouse and keyboard part of the function, the installation ...

Features of Industrial Tablet PCs – Hitech Features of Industrial Tablet PCs – Hitech

Industrial tablet PCs are a branch of computers, which is different from commercial computers mainly because the tablet PC specification can continue to maintain stable performance parameters in different natural environments. Industrial tablet PCs are mainly used in telecommunications, electric power, multimedia systems, national defense and security.

The principle of touch screen control PLC The principle of touch screen control PLC

The control of the PLC itself is completed by the change of the control register D, the input port X, the soft relay condition M and the time relay T and other condition variables, so as long as the condition of these variables can be corrected, the control of the PLC can be completed, and the touch screen can pass through the 232 or ...

Hitec touch screen repair Hitec touch screen repair

How to repair the Hitec touch screen when common problems occur   If the Hitec touchscreen display is confused, there are many reasons. For example, if the battery voltage is too low, the display will be confused. In addition, it may be that the power strip in the mechanical equipment is not installed and the storage area is chaotic ...

Introduction to human-machine interface technology - Hitec Introduction to human-machine interface technology - Hitec

Human-computer interface, the real sense of human-computer interaction method is that people will get rid of any form of interactive interface, the method of entering information is becoming more and more simple, casual, capricious, with the help of artificial intelligence and big data, you can be very intuitive, direct, comprehensive capture of human needs, and...

Precautions for the use of industrial touch film screens - Hitec Precautions for the use of industrial touch film screens - Hitec

1. The resolution needs to be fixed Every time the screen resolution of the industrial touch film screen is adjusted, there will be some shifts, and the solution is to manually adjust or restart the machine, but this frequent adjustment is not good for the machine. ...

Industrial Tablet PC Crash Causes and Solutions - Hitech Industrial Tablet PC Crash Causes and Solutions - Hitech

1. Poor internal heat dissipation of industrial tablet computers Industrial tablet PCs are in a harsh environment, with a lot of dust in addition to high temperatures. When the dust enters the industrial tablet computer, the heat dissipation effect of various electronic components such as boards and CPUs is poor, forming the "crash" of the industrial tablet computer. ...

Touchscreen usage skills - Hitec Touchscreen usage skills - Hitec

1. Run your app in full screen Remove the file name bar and menu bar so you can enjoy the benefits of running the entire screen. 2. Choose bright colors (don't use black) The bright color of the set can hide the finger prints, reduce the dazzling light and star...

Frequently Asked Questions on Human Machine Interface Products - Hitec Frequently Asked Questions on Human Machine Interface Products - Hitec

1. What is the difference between the human-machine interface and the "touch screen" that people often say? Strictly speaking, there is a fundamental difference between the two. Because the "touch screen" is only a hardware part that may be used in human-machine interface products, it is a kind of replacement for the mouse and keyboard part of the function.

Categories and Advantages and Disadvantages of Resistive Touch - Hitech Categories and Advantages and Disadvantages of Resistive Touch - Hitech

Resistance contact is divided into four-wire resistance and five-wire resistance contact, the simple difference is four wires and five wires in the functional area. A constant voltage of 5V is added to each layer of the two-layer transparent metal layer with four-wire resistance analogue technology: ...

Hitec industrial touch screen composition Hitec industrial touch screen composition

The industrial touch screen is an intelligent interface that connects people and machines through touch industrial flashers. It is an intelligent operation flash terminal that replaces traditional control buttons and indicator lights. It can be used to set parameters, flash data, monitor equipment conditions, and draw curves/animations.

The advantage of capacitive touch screen - Hitech The advantage of capacitive touch screen - Hitech

The capacitive skill touch screen uses the current induction of the human body to work. The capacitive contact screen is a four-layer composite glass screen, the inner and outer surface of the glass screen and the interlayer are each coated with a layer of ITO, the outermost layer is a thin layer of silica glass protective layer, the interlayer ITO coating is used as the working surface, and the four corners lead to ...

Frequently Asked Questions about Human-Machine Interface – Hitech Frequently Asked Questions about Human-Machine Interface – Hitech

1. The difference between human-machine interface and configuration software Human-machine interface products, often referred to as "touch screen", include HMI hardware and corresponding special screen configuration software.

The reason for the failure of industrial touch screens - Hitech The reason for the failure of industrial touch screens - Hitech

After clicking on the three corners of the contact screen, enter the offline form (note: different contact screens enter the offline form in different ways). Once in the offline format, click "INITIALIZE", and after clicking, keep clicking "SET-UP-I/O" and then "SET-UP-TOUCH-PANEL". ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top