The failure of the industrial computer is caused by external reasons

Create Date: 2024-8-30 12:03:23|Source: EVOC/EVOC

The temperature is not suitable for the maintenance of the hard drive, if the case temperature reaches 30 degrees Celsius, the temperature of the internal hard drive will reach 40 degrees or higher. We can briefly DIR our industrial computer to achieve the effect of reducing the ambient temperature. 1. Replace high-power CPU and hard disk fans (hard disk fans should be fixed and should not be installed on the hard disk firmware rack to prevent hard disk sensation caused by fan rolling) to speed up heat dissipation; 2. Install an electric fan inside the chassis to exhaust air to the outside of the chassis and add air convection; 3. Install a small axial fan on the cabinet where the industrial computer is placed; 4. Install air conditioning in the control room to reduce the temperature of the space.

                               The failure of the industrial computer is caused by external reasons

1. The ambient humidity is not suitable

The industrial computer is mainly composed of integrated circuits of many electronic components, and its insulation function has a lot to do with the ambient humidity. If the humidity is too high, the circuit board will be short-circuited and incinerated by simply forming a short circuit; If the humidity is too low, static electricity will simply be generated, and some electronic components will be broken down. Therefore, too much humidity and too little humidity will bring potential threats to the industrial computer. The problem of electrostatic protection requires that we need to have a good instrument grounding on the industrial computer. It is worth clarifying that the grounding electrode of the industrial computer is different from the lightning protection grounding on the civil engineering, the grounding electrode site should be three meters away from the control room, and the ∮20 galvanized angle steel is used as the vertical direct ground electrode at 1700mm under the outdoor floor, and the number of grounding meets the grounding resistance of less than 1 ohm (the application of the shake meter test when backfilling), and then the selection of 40 * 40 * 4 galvanized flat steel and the grounding body are reliably welded (each welding point should be carefully treated with anti-rust), and the 25mm copper cable is transferred to the building to the system ground terminal and the industrial computer address. This can effectively reduce the damage caused by static electricity.

Second, the earthquake on the ground is large

In the production of many factories, the motor is required to produce physical bit movement actions such as drag and sensation, which not only brings huge noise, but also brings huge damage to the industrial computer disk, optical drive and floppy drive when the machine is operating. The process of producing disks is getting higher and higher, and the current speed has reached 7200 revolutions per second or even higher. In the large amount of data exchange in the automatic control system, the disk that runs for a long time and at high speed is simply caused by the disk sensation, which leads to the decline of disk read and write ability, slow positioning of the head, and even disk damage; Therefore, it reduces the environmental vibration of the industrial computer and is conducive to the maintenance of the disk. When we are in the process of engineering design, we can keep the industrial computer away from the operation site with a large seismic source as much as possible; If the job address cannot be changed, we can also place sponges and bufferable objects under the industrial control cabinet and box to reduce the damage caused by the sensation.

3. There is a lot of inhalable particulate matter in the air

Most of the materials in many factories require powder for processing, coupled with large external air activity and a lot of sand and dust, a large amount of sticky dust is simply accumulated in the industrial computer, resulting in excessive temperature in the industrial computer and hardware damage. This situation mostly occurs around cooling fans such as CPUs, power supplies, hard disks, and graphics cards. In places where the dust accumulation is light, punctual dust blowing can be selected under the condition that normal production allows. In places where the dust accumulation is serious, dust filter gauze can be placed in the ventilation area of the industrial control chassis and sorted out regularly.

Fourth, the power supply voltage fluctuates greatly and is prone to power failure

With the rapid development of industry and daily life, the demand for electricity is also increasing, and many areas have insufficient power supply, unstable voltage, and easy power outages. The voltage is unstable and the sudden power failure causes the system to restart frequently, and the system files are also simple and therefore lost and cannot be started normally; The head that is performing the read and write action sometimes causes the head to return inaccurately due to power failure, which causes the disk problem of the industrial computer. Therefore, the stability of the power supply in the working environment of the industrial computer is related to the normal operation of the industrial computer. We can choose stabilized power supply and UPS uninterruptible power supply for maintenance, and the specific equipment selection should be determined according to the load power and the amount of operation time that needs to be maintained.

More on that
The cause of the failure point of the industrial computer - EVOC The cause of the failure point of the industrial computer - EVOC

There are 5 categories of common causes of industrial computer problems, which may be caused by processors, power supplies, motherboards, heat dissipation, graphics cards, etc., many of which can be dealt with by self-inspection and repair.

Embedded IPC Features - EVOC Embedded IPC Features - EVOC

Embedded industrial computer can cooperate with the industrial system to complete one or more specific industrial missions in a small industrial site, with open modular structure, strong data processing capabilities, good software development environment and high-performance network and communication support. When the electrical function is fully ...

The difference between industrial switches and industrial switches - EVOC The difference between industrial switches and industrial switches - EVOC

Commercial switches are commercial Ethernet switches, which are generally used in enterprise work networks and other occasions, and are generally rack-type, installed in enterprise computer rooms, and generally require high reliability, 24-hour uninterrupted long-term operation, large bandwidth, and more interfaces. ...

Key points of industrial computer fault judgment - EVOC Key points of industrial computer fault judgment - EVOC

1. Device operation system First: Review the settings in the CMOS and restore to factory settings if needed. Secondly: pay attention to the parameters of the hard disk, the temperature of the CPU, etc. Observe whether the information displayed during the self-test of the industrial computer is consistent with the actual hardware equipment. 2. Device software ...

The detailed advantages of the industrial computer - EVOC industrial computer The detailed advantages of the industrial computer - EVOC industrial computer

The industrial computer is similar to the general accounting machine, and the industrial computer has important accounting machine attributes and characteristics, such as the computer motherboard, CPU, hard disk, memory, peripherals and interfaces, and has an operating system, control network and protocol, accounting ability, and friendly man-machine interface. But there is also a ...

Industrial computer chassis classification - EVOC industrial computer Industrial computer chassis classification - EVOC industrial computer

(1) THE HEIGHT IS GENERALLY DIVIDED INTO 1U (44MM*430MM*XX), 2U (88*430*XX), 3U, 4U (176MM*430MM*XX), 5U, 6U, 7U, 8U, ETC., A 1U HEIGHT IS 44MM, AND OTHER HEIGHTS ARE IN ORDER; (2) Length: National ...

The difference between industrial control motherboard and commercial motherboard - EVOC industrial computer The difference between industrial control motherboard and commercial motherboard - EVOC industrial computer

The industrial control motherboard is an important part of the industrial computer, which can get used to the messy environment and long-term high-load work on the industrial site. The differences from commercial motherboards are: First, the materials and planning of components Commercial motherboards ...

The reason why the IPC starts up for a long time The reason why the IPC starts up for a long time

1. Close the auto-start item of the system boot file 2. RUN SCANDISK TO CHECK THE DISK FOR BAD SECTORS 3. Run the disk defragmenter to eliminate the fragmentation 4. Run the Disk Cleaner to eliminate the ...

The difference between industrial control motherboard and commercial motherboard - EVOC The difference between industrial control motherboard and commercial motherboard - EVOC

1. Scale specifications: Commercial motherboards currently mainly use ATX architecture; In order to adapt to a variety of application environments, industrial motherboards use motherboards of various sizes and specifications, including ATX, Micro-ATX, LPX, POS and other specifications. 2. The support of the expansion slot: commercial motherboards can often only supply ...

Industrial Tablet PC Resistive Screen Fault and Solution - EVOC Industrial Tablet PC Resistive Screen Fault and Solution - EVOC

Fault 1: The mouse is only moved in a small area or is forbidden to touch This usually happens when you first install the drive, run the contact screen calibration procedure. After changing the resolution of the industrial tablet, the contact screen calibration procedure is also run. Fault 2: Mouse 1 ...

EVOC made a wonderful appearance at the CIIF with its solutions EVOC made a wonderful appearance at the CIIF with its solutions

On September 19, the 20th China International Industry Fair with the theme of "innovation, intelligence and green" was held in the National Convention and Exhibition Center (Shanghai). As a well-known enterprise in the field of industrial automation, EVOC brings four major professional solutions: intelligent manufacturing, artificial intelligence, Internet of Things, and rail transit.

Industrial computer keyboard and mouse failure treatment method - EVOC Industrial computer keyboard and mouse failure treatment method - EVOC

The industrial computer, that is, the industrial computer, the primary structure and operating principle are the same as that of ordinary computers, the difference is that the industrial computer adopts a steel structure chassis, with fixed strips inside, and has a high anti-magnetic, dust-proof and anti-oscillation ability, which is suitable for complex industrial sites. The IPC can be used for data receiving.

EVOC IPC downtime analysis and solutions EVOC IPC downtime analysis and solutions

Downtime is a common problem of industrial computers, and solving downtime can ensure the high reliability and real-time performance of industrial computers. The following is an analysis of the common causes and solutions of industrial computer downtime. 1. Too much dust causes downtime ...

The internal structure of the industrial computer - EVOC The internal structure of the industrial computer - EVOC

There are many internal structures of industrial computers, and most of the hardware is installed inside the industrial computers, such as passive backplanes, industrial power supplies, CPUs, motherboards, memory, hard disks, graphics cards, fans, etc. 1. Passive base plate. The slots of the passive backplane consist of multiple slots for the ISA and PCI buses ...

The difference between PCI slot and PCI-e slot in EVOC industrial computer The difference between PCI slot and PCI-e slot in EVOC industrial computer

When selecting industrial computers, we often encounter PCI and PCI-e expansion slots, what are the differences between the two? 1. The color is different. In IPC motherboards, the PCI slot is milky white, while the PCI-e slot is black. 2. The transmission rate is different. PCI slot max data ...

There is no display solution after the industrial computer is powered on - EVOC There is no display solution after the industrial computer is powered on - EVOC

1. There is no display after the industrial computer is powered on 1. When the industrial computer is turned on, there is a connected alarm sound and the display does not appear, which may be poor memory oxidation contact or memory failure, and the memory is reinserted or replaced after power failure. If after replacing the memory, the IPC boots up and still has the alarm ...

EVOC IPC problem analysis EVOC IPC problem analysis

In fact, there is not much difference between the industrial computer and the general computer, only the power supply and the motherboard are nominally more stable and reliable than the general computer, after all, the requirements of the industrial site are a little higher than the civil one, the so-called industrial computer encounters the same problems as the general computer, such as the black screen of the crash can not be started ...

Industrial computer start-up alarm, listen to the sound analysis of the alarm - EVOC Industrial computer start-up alarm, listen to the sound analysis of the alarm - EVOC

The first type: the BIOS of the Award 1 short - the system starts normally 2 Short - Conventional Fault 1 long and 1 short – RAM or motherboard makes mistakes 1 long and 2 short - the fault of the display or graphics card 1 long and 3 short - the keyboard controller is at fault 1 Long 9 Short - Motherboard Fla ...

Common problems and solutions of industrial computer - EVOC industrial computer Common problems and solutions of industrial computer - EVOC industrial computer

1. It can be powered on but not lit 1. There is no alarm sound display of Didi when booted, maybe it is poor contact of memory oxidation or there is a problem with the memory itself, the solution is to wipe the memory with an eraser and reinsert it back after power-off, and replace the memory with its own problem.

The difference between PCI, CPCI, and PXI slots in industrial computers The difference between PCI, CPCI, and PXI slots in industrial computers

1. PCI is the abbreviation of Peripheral Component Interconnect (Peripheral Component Interconnect specification), which is the main expansion slot of industrial computers, and it is also the type of slot with the most on the board of industrial motherboards.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top