Product Introduction
Digital Display Controllers (Temperature Controllers)
RD Series (RD100 / RD400 / RD500 / RD700 / RD900)
Measurement accuracy: ±0.2% of displayed value
Sampling cycle: 0.25 seconds
11-segment LCD display
Dedicated Loader communication function
Plug-in construction
Main features Four types of settings can be registered
Four sets of setpoints (SV) can be logged in and switched via digital input (DI).
Rich outputs
Analog transmission outputs may not be available depending on the type and type of control.
Rich output function combinations.
The number of points for digital output is limited depending on the model and specifications.
Analog transmission outputs may not be available depending on the type and type of control.
In the case of RD100, you can choose between communication and digital inputs.
Adjustable Control Responsiveness (POST Fine-Tuning Function)
The responsiveness of the PID control characteristics calculated by the automatic calculation (AT) can be easily adjusted through the POST fine-tuning function. And choose from 6 levels of POST fine-tuning to the responsiveness you need.
Dedicated LOADER communication function
All models are equipped with a dedicated Loader communication function as standard.
It is easy to connect with a computer and set up with PROTEM 2 software
Main specifications:
Number of input points: 1 point
Input Type *Please refer to the input value range code table
1) **Class: Thermocouples K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
2) The second category: temperature measuring resistor Pt100, JPt100
Sampling cycle: 0.25 seconds
Measurement accuracy: ± (0.2% of displayed value + 1 digit) *Varies depending on the input range
OUT1
1) Relay contact output: 1A contact
2) SSR voltage pulse output: DC 0/12V
3) Current output: DC 0-20mA, DC 4-20mA
4) Electric pressure output: DC0-5V, DC1-5V, DC0-10V
5) Open collector output: conversion mode
6) SSR (three-terminal bidirectional thyristor) output: rated 0.5A
< Optional Specifications >
OUT23 (OUT23) *You can select from different functions such as temperature control, alarm, heater disconnection alarm, loop disconnection alarm, and FAIL
1) Relay contact output: 1A contact
2) SSR voltage pulse output: DC 0/12V
3) Current output: DC 0-20mA, DC 4-20mA
4) Electric pressure output: DC0-5V, DC1-5V, DC0-10V
5) Open collector output: conversion mode
6) SSR (three-terminal bidirectional thyristor) output: rated 0.5A
Alarm/event output function (* 4 points more): temperature alarm, heater disconnection alarm, disconnection alarm, FAIL, etc
CT input for heater disconnection alarm (*2 points more)
Analog Transmission Output: The output method is the same as that of Output 1 (OUT 1) *Output from the Output 2 (OUT 2) position
Digital/Event/External Contact Input Function: * 2 points more
Communication function: RS-485 communication mode
< general specifications >
Power supply voltage (rated): AC100 - 240V / AC24V / DC24V
Ambient temperature: 0-50°C
Mass: RD100 about 120g
RD400 is about 185g
RD500 is about 190g
RD700 is about 200g
RD900 is about 250g
Safety Specification: UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE: Low Voltage Directive (LVD) EN61010-1
EMC Directive EN61326-1
RCM EN55011
|
More on that
|
Japan RIKA RKC Program Controller PZ400 / PZ900 Number of input points: 1 point
Introduction: Japan RIKA RKC program controller PZ400 / PZ900 Input points: 1 point, power supply voltage (rated): AC100 - 240V, AC/DC24V, the initial installation is simple, can quickly respond to the replacement of the instrument.
peculiarity
The large LCD screen can display a variety of information at the same time.
|
|
Japan RIKA RKC single-phase power conditioner THV-10 Power supply voltage: AC100~240V
Main features
Settings and data collection can be performed via host communication
RS-485 serial communication function is available. (Optional)
It can be connected to a PLC or a network device for setting and data collection.
Easily connected to ...
|
|
RKC thermostat RB100FD03-MN-4*2N-6N/AN/Y 1a contact
Main features
Four settings can be registered
Four sets of setpoints (SV) can be logged in and switched via digital input (DI).
Rich outputs
Analog transmission outputs may not be available depending on the type and type of control.
Rich output ...
|
|
RKC thermostat RH400WD02-V8*AN Pt100, JPt100
Main features
Adjustable Control Responsiveness (POST Fine-Tuning Function)
The responsiveness of the PID control characteristics calculated by the automatic calculation (AT) can be easily adjusted through the POST fine-tuning function. And you can choose from 6 levels of POST fine-tuning function to choose the sound you need.
|
|
The RKC LE100 / LE110 back-pressure level gauges output an 8-point level alarm
Main features
Measure the liquid level with 1 catheter
An inert gas is supplied to a conduit installed in a tank, and the level is measured by the back pressure that occurs in the conduit corresponding to the liquid level.
LE110 is a LE100 type back pressure type level gauge equipped with differential pressure (level gauge pressure and ...
|
|
Japan RIKA RKC communication converter COM-ME series SRZ: host communication
Main features
COM-ME-1
Ethernet (MODBUS/TCP) communication converter
This converter is used to connect our SRZ series, FZ series, and GZ series to an Ethernet network (MODBUS/TCP).
This converter is used to transfer our SRZ ...
|
|
Japan RIKA RKC HBA-22 heater disconnection alarm
Main product specifications:
Japan Rika RKC HBA-22 heater disconnection alarm, for relay contacts and drive SSR, corresponding to the controller with a short proportional cycle (about 2 seconds or more) for control system heater disconnection alarm.
HBA-22 (for single-phase SSR control ...
|
|
Japan RIKA RKC LE110 level sensor/back pressure level gauge
Product Description:
Japan Rikaku RKC LE110 Level Sensor/Back-pressure Level Gauge can measure the liquid level with a single conduit, supply inert gas to the conduit installed in the tank, and measure the liquid level by using the back pressure that occurs in the conduit corresponding to the liquid level. LE110 ...
|
|
Japan RIKA RKC thermostat RH100 working voltage 220V
Product Details
Control Type: Temperature
Model: RH100
Opening size: 40.5*40.5
Mounting type: card type
Output signal: 4-20mA
Operating voltage: 220V
Dimensions: 48*48*100mm
...
|
|
RKC Resin Pressure Converter PCT-300 Power supply voltage: AC100—240V
Main features
Connect controllers, displays, and recorders
The signal of the resin pressure sensor is converted into an analog output that can be connected to a controller, display and recorder.
Up to 4 points of analog output
Up to 4 points of analog output are possible
DC0— ...
|
|
Japan Rika RKC AE500 digital display Sampling period 0.5 seconds
Product Introduction:
Japan RIKA RKC AE500 digital display, a large LED display with excellent visibility that can be seen from the soft place; The upper limit input alarm value and the lower input alarm value can be assigned to 4 outputs; The communication function (RS-485) can be ...
|
|
Japan RIKA RKC RB400 temperature controller Pt100, JPt100
Number of input points: 1 point
Input Type *Please refer to the input value range code table
1) Class ***: Thermocouples K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
2) The second category: temperature measuring resistor Pt100, JPt100
Sampling period: 0.25 ...
|
|
Japan RIKA RKC RD100-MN-4*2N-NN digital display thermostat 1a contact
Product Introduction
Number of input points: 1 point
Input Type *Please refer to the input value range code table
1) **Class: Thermocouples K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
2) The second category: temperature measuring resistor Pt100, JPt100
...
|
|
Japan RIKA RKC single-phase power conditioner THV-10
Introduction: Japan RIKA RKC single-phase power conditioner THV-10 standard is equipped with automatic/manual switching, slope setting function, buffer rise/buffer drop function, external contact input, two-position control, RKC dedicated communication and other functions
Features:
It can be done via host communication ...
|
|
Japan Rika RKC CB100L Limit Controller Sampling cycle: 0.5 seconds
Main features
FM compliant temperature high/low limit controller
Limit the controller's actions
When the temperature controller detects an abnormal increase in temperature, such as a malfunction of the temperature control device, the limiting controller outputs a signal (relay contact output). ...
|
|
Japan Rika RKC PZ400 digital program controller 0.05 seconds
Product Details
PA400
The PZ400 is a program controller that can easily set the time for the rise, maintenance and fall of complex target values.
It is easy to operate with the direct setting button
The program capacity is 16 models × 16 segments (linkable) ...
|
|
Japan RIKA RKC REX-P24 Program Controller Sampling cycle: 0.5 seconds
Introduction: Japan RIKA RKC REX-P24 program controller (temperature controller) sampling cycle: 0.5 seconds, power supply voltage (rated): AC100-240V, ambient temperature: 0-50 °C.
peculiarity
The small body (48mm) can be equipped with program control as standard, ...
|
|
Japan RIKA RKC communication converter COM-ME-1 Mass: about 150g
Introduction: Japan Rika RKC COM-ME-1 is a communication converter for our SRZ series, FZ series, and GZ series and Ethernet (MODBUS/TCP) connection.
peculiarity
This converter is used to connect our SRZ series, FZ series, and GZ series to ...
|
|
Japan Rika RKC THW-A three-phase power conditioner
Product Introduction:
Japan Rikaku RKC THW-A three-phase power conditioner, a digital control operator equipped with a display and setting buttons in the front, when the soft start/soft stop is set to 0, it can respond to high-speed temperature rise control with fast response; Because of the constant current control ...
|
|
Japan RKC physical and chemical thermostat REX-P200 opening size 96*96(mm)
Product Details
Imported: No
Customization: No
Brand Name: RKC/Physical and Chemical
Model: REX-P200
Control Type: Temperature
Control Mode: Intelligent Temperature Control Regulator