Settings and data collection can be performed via host communication
RS-485 serial communication function is available. (Optional)
It can be connected to a PLC or a network device for setting and data collection.
The analog transmission output can be easily connected to the measuring instrument
It can be equipped with an analog transmission output function. (Optional)
Because it can be output as a valid value, it can be easily connected to measuring instruments such as recorders and digital displays.
Simple data management via RKC-specific communication
RKC-specific communication is standard.
It can be connected to a PC via USB via our communication converter COM-KG. Various settings and setpoints can be easily saved to a PC, and various setpoints can be uploaded to the THV-10 from a PC.
RKC dedicated communication is set up exclusive. Do not use for control or operation.
It is equipped with abundant functions as standard
It is equipped with functions such as automatic/manual switching, slope setting function, buffer rise/buffer descending function, external contact input, two-position control, and RKC dedicated communication.
Approximately 50% lightweight
Succeeded in achieving a significant weight reduction target for the 20A/30A type. Realize the lightweight of the equipment control panel or control box.
Comparison with our THV-1 (20A/30A).
No transformer flux density limitation for transformer miniaturization (optional)
The transformer's primary measurement control function suppresses excessive current that occurs due to a momentary power failure on the load side. If the transformer is controlled in the first test, the transformer control function is required. There is no transformer flux density limit.
Detects non-linear load heater breaks
A maximum of 3 knee points can be set to match the load profile with the characteristics of the heater. It is used for loads with large resistance values and temperature dependence (lamps, heaters, etc.).
The inflection point can be set automatically.
Main specifications:
Maximum load capacity: AC20A, AC30A, AC45A, AC60A, AC80A, AC100A
Control mode: phase control/zero cross control (switchable)
Applicable loads:
a) Phase control: Linear (impedance type) loads, transformer primary side control (magnetic flux density approx. 1.25 T or less)*1 Please refer to the transformer primary side control protection function
b) Zero cross control: straight (impedance type) load
Input Signal:
a) DC current input DC 4 to 20mA (input internal resistance: 50Ω)
b) DC voltage input DC 1 to 5V (input internal resistance: 30kΩ)
c) DC voltage input DC 0 to 10V (input internal resistance: 30kΩ)
d) Voltage pulse input DC 0/12V (input internal resistance: 30kΩ)
Output mode
a) Phase angle ratio, voltage ratio, voltage self-multiplication ratio
b) Constant current control and power proportional control
a) Standard configuration. b) Optional.
Power frequency: 50/60Hz shared (automatic identification)
Standard Features:
a) Automatic/manual switching (optional external setting)
b) Slope setting function (optional external setting)
c) Slow ascent/descent function: 0.0 to 199.9 seconds
d) External contact input (DI): 1 point, no voltage contact input
(Can be used to switch between RUN/STOP, Auto/Manual, Phase Control/Zero Cross Control, Slow Up/Slow Down Function/Active, Set Data Lock/Unlock, Overcurrent Alarm Function)
e) 2nd position control [external upper and lower limit setter (knob) is optional]
f) RKC-specific communication interface: Our COM-KG communication converter can be used through the RKC-specific communication protocol.
Optional features:
a) Alarm output: 1 point
Output: Transistor output, synchronization method Allowable load current: 100mA, load voltage: DC30V or less
Selectable excited/non-excited (FAIL alarm can only be non-excited)
(Heater disconnection alarm, power regulator fault alarm, power frequency abnormality alarm, overcurrent alarm, FAIL alarm can be selected)
b) Heater disconnection alarm
Current measurement accuracy
20A/30A: ±1.5A (20A or less for current measurement: ±1.2A, 10A or less for current measurement: ±1.0A)
45A/60A/80A/100A : Maximum rated current±5%
c) Current limiters
Setting range: 20A, 30A: 0.0 to 32.0A, 45A: 0.0 to 55.0A, 60A: 0 to 70A, 80A: 0 to 90A, 100A: 0 to 110A
d) Transmission output
Output voltage: DC 0 to 10V (Allowable load resistance: 1kΩ or more)
e) Communication Functions
Interface: EIA standard RS-485
Protocols: RKC communication (ANSI X3.28-1976 subcategory 2.5 A4 standard), MODBUS-RTU
Communication speed: 9600, 19200, 38400, 57600BPS
< general specifications >
Operating temperature range: -15 - +55 °C (guaranteed range)
Power supply voltage for load: AC85 to 264V (including power supply voltage fluctuation) Rating: AC100 to 240V
Quality:
Approx. 0.45kg (20A, 30A)
Approx. 1.2 kg (45A, 60A)
Approx. 1.8 kg (80A, 100A)
Safety Specifications :
UL UL508 (File No. E177758)
cUL C22.2 No.14 (File No. E177758)
CE marking *2:
Low Voltage Directive: EN60947-4-3 (Form 4) Rated insulation voltage: 690 V
EMC Directive: EN60947-4-3 (Form 4)
RoHS Directive: EN50581
|
More on that
|
Japan RKC physical and chemical thermostat RKC-CD901-D008M weight 0.3Kg
Product RKC CD901-D008M Overview: High-performance multi-function high-specification controller, sampling cycle 0.1 seconds, accuracy 0.1%, stable heating/cooling function, abundant event output specifications, standard corresponding to overseas safety standards.
Details of the product.
Processing customization: ...
|
|
Japan RKC physicochemical modular controller SRZ sampling cycle 0.25 seconds
Product parameters
Measurement accuracy: ±0.2% of displayed value
Sampling cycle: 0.25 seconds
One unit can control 4 channels
I cope with preceding exclusive communication
Plug-in construction
Digital inputs and outputs are available
A communication converter that can be connected to a variety of fieldbuses
...
|
|
Japan RIKA RKC SST series three-phase solid state relay
Product Introduction:
Japan Rika RKC SST series three-phase solid-state relay, screw-mounted type, equipped with a function to detect component faults.
1) Screw mounting type
2) Maximum load capacity: AC10A, AC20A, AC30A
3) Power supply voltage: AC...
|
|
Japan RIKA RKC PG500 resin pressure sensor Abundant input and output
Main features
Equipped with a large LED display
A large, high-brightness LED display is used to achieve visibility even from a distance
Abundant inputs and outputs
Equipped with digital input, analog output, alarm output, communication function, etc.
Product Introduction
...
|
|
RKC thermostat CB100FD10-M*CN communication mode: RS-485
Main features
FM compliant temperature high/low limit controller
Limit the controller's actions
When the temperature controller detects an abnormal increase in temperature, such as a malfunction of the temperature control device, the limiting controller outputs a signal (relay contact output). ...
|
|
Japan RKC physical and chemical digital display controller SA100 mass about 120g
Product parameters
Brand: RKC/Physicochemical
Model: SA100.
Sample time: 0.5 seconds.
AC: RS-485.
Power supply voltage (rated value): AC100-240V/AC.
Working environment temperature: 0-50°C.
...
|
|
Japan RKC physical and chemical digital display controller CB100 weighs 170g
Product Details
Brand Name: RKC/Physical and Chemical
Model No.: CB100
Control Type: Temperature
Control Mode: Intelligent Temperature Control Regulator
Temperature Range: Selectable (°C)
Temperature Measurement Error: 1(°C)
Cut-out size :48* ...
|
|
Japan RIKA RKC SBR-EW100 hybrid recorder The ambient temperature is 0~50°C
Product Introduction:
The Japan Rika RKC model is SBR-EW100, and the recorders of this series use "multiple displays" to confirm the data at a glance. This model is a replacement for the SBR-EY100, which was discontinued in 2005, and is available in 5 sizes. There are also products of the same series ...
|
|
Japan RIKA RKC communication converter COM-ME-1 Mass: about 150g
Introduction: Japan Rika RKC COM-ME-1 is a communication converter for our SRZ series, FZ series, and GZ series and Ethernet (MODBUS/TCP) connection.
peculiarity
This converter is used to connect our SRZ series, FZ series, and GZ series to ...
|
|
Japan RKC physical and chemical COM-JE PLC communication converter
Main features
COM-JE
PLC communication converter
The controller and PLC can be connected without a program.
The COM-JE acts as the host computer and stores the controller's data in the PLC's registers.
It is only necessary to operate the PLC register commands, and the number of controllers can be easily handled.
|
|
Japan Rika RKC CD701-DK01-MN*NN CD701 thermostat 0.5 seconds
Product Introduction
Number of input points: 1 point
Input Type: *Input range refers to the input value range code table (model · price)
1) Thermocouples: K, J, T, S, B, E, B, N, W5Re/W26Re, PLII., U, L
2) Temperature Measuring Resistance: Pt100, JPt1 ...
|
|
Japan RKC physical and chemical heater disconnection alarm HBA-21 working voltage 220V
Product features
HBA-21 (for single phase contact control system)
Input Type: Current Detector (CV-1-□)
Detectable load current, depending on AC5A, AC30A, AC100A (CV-1 rating
Programmable range: CV-1 rating ...
|
|
Japan physical and chemical RKC RD400F501-4N-4*1N-5N-AN thermostat
The digital display controller [ process / temperature controller ] has a plug-in structure with good maintenance performance; At the same time, the product depth has been reduced by 40% compared to the original model (CD series). It is the latest standard temperature controller.
Product parameters
Brand Name: RKC/...
|
|
RKC thermostat SA100FK06-MM-3*GN-NN/Y 250Ω external resistor
Main features
FM compliant temperature high/low limit controller
Limit the controller's actions
When the temperature controller detects an abnormal increase in temperature, such as a malfunction of the temperature control device, the limiting controller outputs a signal (relay contact output). Should...
|
|
Japan RKC physical and chemical back pressure level gauge LE100 voltage 220v
Product parameters
Brand Name: RKC
Model: LE100/LE110
Measuring range: 800m
Resolution: 900*890
Supply voltage: 220V
Dimensions: 800*900(mm)
Explosion-proof grade: Class 1
Main features ...
|
|
Japan Rika RKC resin pressure digital display controller HA930 Sampling cycle: 0.025 seconds
Main features
It can be connected directly to a strain gauge resin pressure sensor
It can be directly connected and controlled with our pressure sensors.
High-speed sampling cycle of 0.025 seconds
The high-speed sampling cycle can be carried out in response to rapidly changing processes.
|
|
Japan Rika RKC PZ400/PZ900 Program Controller (Temperature Controller)
Main features
The current status is clear at a glance
The large LCD screen can display a variety of information at the same time, and the operating status can be clearly displayed.
It is clear at a glance whether the program is working correctly or not.
Easy to operate (direct button setting)
Commonly used settings can be ...
|
|
Japan Rika RKC SR Mini HG SYSTEM (H-PCP-J) modular controller
Product Introduction:
Japan RIKA RKC SR Mini HG SYSTEM (H-PCP-J) modular controller, which can be connected to each PLC without program; Compatible with output ratio function (digital output module H-DO-G-D); Using the pulse of the rotary encoder as a module ...
|
|
Japan RIKA RKC modular controller SRZ 1 can control 4 channels
Main features
1 small module condensed with 4 temperature controllers
Four CHs can be controlled using one compact module. (Heating and cooling control type is 2 CH)
Temperature control module (Z-TIO) can be connected to up to 16 units (up to 64CH)
A variety of specializations are available.
|
|
Japan Rika RKC REX-P300 Program Controller (Process/Temperature Controller)
Product Introduction:
Japan Rika RKC, model REX-P300 has been discontinued (replacement product PF900), program controller (process / temperature controller).
Number of input points: 1 point maximum
Input Type: General Purpose Input ※ The input range refers to the input value range code table ...
|
|