Introduction: E+H/Endershaus Analog Total Chlorine Sensor CCS120, CCS120 Analog Sensor for Standard Measurement of Total Chlorine. Even in the event of flow or conductivity fluctuations, reliable measured values are transmitted, the disinfection loop is controlled, and the water is free of bacteria. At the same time, the sensor is calibrated and maintained with long intervals, reducing maintenance costs.
Features:
The calibration cycle is 1-3 months under stable operating conditions
Prefabricated laminated caps allow for easy lamination changes
The measurement is not affected by the flow rate when the flow rate exceeds 30 l/h
Product parameters
Measuring principle
Total chlorine
apply
Drinking water, process water, sewage, swimming pool water
peculiarity
Fluorescence total chlorine measurement.
Measuring range
0.1...10ppm total chlorine; pH 6.5...9.5
Measuring principle
- Total chlorine includes residual chlorine (HOCl, OCl) and bound chlorine (chloride).
- The polarization voltage between the working electrode and the counter electrode is constant, resulting in an electrochemical reaction.
- Negligible relationship with pH.
devise
Closed fluorescence two-electrode total chlorine sensor.
Material
Sensor rod: PVC
Laminated cap: PPE
Dimensions
Diameter: Approximately 25mm
Length: 210mm
Process temperature
5...45°C
Process pressure
0...3bar
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the E+H/Endershaus Radar Measurement Travel Time Principle Micropilot FMR57 product, if you are interested in the Radar Measurement Travel Time Principle, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience
|
More on that
|
E+H/Endershaus Liquiphant FTL50
Introduction: E+H/Endershaus Liquiphant FTL50 and Liquiphant FTL50 tuning fork limit detection switches can be used in explosion hazard areas, with various international approvals, suitable for all industries.
Features:
Available for functional safety ...
|
|
E+H/Endershaus digital conductivity sensor Condumax CLS15D with IP68 degree of protection
Description: E+H/Endershaus digital conductivity sensor Condumax CLS15D, the Condumax CLS15D digital conductivity sensor is particularly suitable for low conductivity measurement ranges. It can be used in a wide range of applications and can be reliably measured with high precision, even in hazardous areas.
...
|
|
E+H/Endershaus Mass Flow Meter Proline Promass E 500 Measuring Tube 1.4539
Description: The E+H/Endershaus mass flow meter Proline Promass E 500 is a robust and cost-effective solution for long-term use for high-precision liquid and gas measurements in a wide range of standard applications in different industries. In combination with the innovative split transmitter, ...
|
|
E+H/Endershaus Tuning Fork Level Meter FTL20-0220 Limit Level Detection Switch
Product introduction: FTL20-0220 is an all-in-one limit detection switch. Typically used in tank farms, vessels and pipelines, in cleaning and filtration systems and cooling and lubrication tanks, for overfill protection or to prevent pumps from running dry.
Tuning fork level meter FTL20-002B
...
|
|
E+H/Endershaus Guided wave radar measures travel time principle Levelflex FMP51
Introduction: E+H/Endershaus Guided Wave Radar Measuring Stroke Time Principle Levelflex FMP51, Levelflex FMP51 is suitable for level measurement under extreme conditions in the process industry, such as high temperature and high pressure. Even if the liquid level fluctuates, foams or there is an obstacle in the tank...
|
|
E+H/Endershaus Mass Flow Meter Proline Promass I 100 Gas Error ± 0.5%
Description: The E+H/Endershaus mass flow meter Proline Promass I 100 measures viscosity in-line in the same way as standard Coriolis mass flow meters, in addition to measuring mass flow, density and temperature. In combination with the smallest transmitter available, the Promass I 100 flow meter ...
|
|
E+H/Endershaus Process Controller RIA45 Panel Mount
Introduction: The E+H/Endershaus process controller RIA45 displays analogue measured values with a process measuring instrument, evaluates and calculates them. The two-wire sensor can be powered via a loop.
Features:
5-digit 7-segment measured value LC backlit display
1 or 2 universal inputs
2 ...
|
|
E+H/Endershaus Radar Measurement Micropilot FMR60 Measurement accuracy +/-1mm
Introduction: E+H/Endershaus radar measures the Micropilot FMR60, the first 80 GHz radar designed by Endress+Hauser to comply with the IEC 61508 international functional safety standard.
Features:
Hardware and software designed in accordance with IEC 61508 ...
|
|
E+H/Endershaus radar measures travel time principle Micropilot FMR56 with a measurement accuracy of 3 mm
Introduction: E+H/Endershaus Radar Measurement Journey Time Principle Micropilot FMR56, Micropilot FMR56 is designed for level measurement in light conditions such as bulk bins or containers. Micropilot is suitable for continuous, non-contact use of solid bulk materials such as powders and granules.
|
|
E+H/Endershaus pH electrode Memosens CPS91E is IP68 rated
Description: E+H/Endershaus pH electrode Memosens CPS91E, Memosens CPS91E with Memosens 2.0 digital technology supports extended data storage, service predictive maintenance and IIoT IIoT.
Features:
Reliable measurement of heavily contaminated media: open-hole ...
|
|
E+H/Endershaus Capacitive Level Measurement Liquicap FMI52 Vacuum pressure 100 bar
Introduction: E+H/Endershaus Capacitive Level Measurement Liquicap FMI52, Liquicap FMI52 is a reliable fully insulated probe for continuous level measurement of liquids, especially in small storage tanks, adherent media and extreme high temperatures.
|
|
E+H/Endershaus Mass Flow Meter Proline Promass 40E Measuring Tube 904L
Introduction: The E+H/Endershaus mass flow meter Proline Promass 40E has earned a good reputation for its cost-saving use of the Coriolis principle. The flow meter with integrated Promass 40 transmitter is suitable for low-end measurement applications, providing high-precision liquid and gas flow measurement, ...
|
|
E+H/Endershaus digital conductivity sensor Indumax CLS50D
Description: E+H/Endershaus Digital Conductivity Sensor Indumax CLS50D, Indumax CLS50D is an inductive conductivity sensor for standard, hazardous and high-temperature environments.
Features:
Durable, chemically resistant, suitable for harsh conditions ...
|
|
E+H/Endershaus Gauge Pressure Transmitter Cerabar PMP75 with a measuring range of 100 m to 400 bar
Introduction: E+H/Endershaus Gauge pressure transmitter Cerabar PMP75, a digital pressure transmitter with metal diaphragm seal, is mainly used in the process industry and the hygienic industry to measure the pressure, level, volume and mass of liquids or gases. The transmitter is suitable for high temperature and high pressure occasions, ...
|
|
E+H/Endershaus Travel-time radar measures Micropilot FMR10
Description: E+H/Endershaus Travel-time radar measurement Micropilot FMR10, Micropilot FMR10 for continuous, non-contact level measurement, particularly suitable for use in the water and wastewater industry, as well as for utilities in various industries. The FMR10 is the first to use Bluetooth ® for commissioning, operation and maintenance.
|
|
E+H/Endershaus field temperature transmitter iTEMP® TMT142
Introduction: The E+H/Endershaus field temperature transmitter iTEMP® TMT142 demonstrates unmatched reliability, precision and long-term stability in critical process applications across all industries. The configurable temperature transmitter not only transmits the conversion signal from the RTD sensor and thermocouple, ...
|
|
E+H/Endershaus Hydrostatic Level Gauge Deltapilot FMB70 Measurement accuracy 0.1%
Description: E+H/Endershaus Hydrostatic level sensor Deltapilot FMB70, with anti-condensation CONTITE measuring cell and double-chamber housing, mainly used in the process industry and hygiene, measures the level of liquids or slurry media in open or closed containers, independent of foam ...
|
|
E+H/Endershaus Conductive Limit Detection Three-rod Probe 11363Z
Introduction: E+H/Endershaus Conductive Limit Detection Three-Pole Probe 11363Z, 11363Z High Corrosion Resistance Probe, can be used for limit level detection and overflow protection in plastic or non-conductive containers.
Features:
Various process connections are available: Thread G1 1/ ...
|
|
E+H/Endershaus Sheath TA535 insertion depth 10 mm
Introduction: E+H/Endershaus Sheath TA535, with its hexagonal extension, is suitable for industrial applications with medium and advanced process pressures. It is generally fixed to pipes or tanks that use threaded connections. Due to its special construction, it can carry a 6 mm diameter (0.24 in) probe ...
|
|
E+H/Endershaus digital ORP electrode Memosens C PF82E with a length of 120 mm
Introduction: E+H/Endershaus Digital ORP Sensors The Memosens CPF82E is a robust digital ORP sensor that reliably measures ORP values under harsh conditions. Stain-resistant PTFE diaphragm, low maintenance workload, built-in mounting bracket, easy to install...
|
|