JF5 series base enclosed terminal block is suitable for the frequency of 50Hz or 60Hz, the rated voltage to 660V, the rated cross-sectional area of 1.5-25mm2 round copper wire for connection. This series of products is connected by screw crimping, and the wire end needs to be crimped before it can be connected to the terminal block. It is installed on G-rails.
Comply with standards: GB/T 14048.7, IEC 60947-7-1.
This article introduces CHINT/CHINT terminal block — JF5 series AC contactor products, if you are interested in CHINT/CHINT contactor, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT HZ5 series combination switch
HZ5 series combination switch is mainly used for AC 50Hz or 60Hz, voltage 380V and below electrical circuits as power switch and cage induction motor starting, commutation, variable speed switch, can also be used for control line switching.
Comply with standards: GB/T 14048.3, IEC 60947-3.
...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-1250
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-250
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT LAY39 series buttons
LAY39 series button is suitable for AC 50Hz or 60Hz, rated working voltage 380V and below or DC working voltage 220V in industrial control circuits, as electromagnetic starters, contactors, relays and other electrical circuit control, with indicator light button is also suitable for light signal ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-40/02
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-1000
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT YBLX-HL series travel switch YBLX-HL/5030
YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with the standard ...
|
|
CHINT/CHINT Terminal Appliance —NU210-40 Surge Protector
NU210-40 is a surge protective device with short circuit protection. Connect to circuits and devices with an AC rated voltage of 230/400V, 50Hz. Able to protect terminal electrical equipment from the impact of induced lightning, it has the ability to protect against indirect lightning and direct lightning effects or other transient overvoltage surges.
|
|
CHINT/CHINT AX-5 auxiliary contacts
The AX-5 auxiliary contact is suitable for AC 50Hz, the agreed heating current to 6A, the rated voltage to 415V or the DC rated voltage to 130V, and it is assembled with the NL1 residual current action circuit breaker for the signal indication of the long-distance circuit breaker.
Conform to the standard: GB/T 14048.5, ...
|
|
CHINT/CHINT NXB-63H miniature circuit breaker
Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated working voltage (U): 230V-(1P, 1P+N), 400V-(2P-4P, 3P+N);
Rated insulation voltage (Ui): 500V;
Frequency: 50Hz
Electromagnetic tripping ...
|
|
CHINT/CHINT OUVT-X1 over/undervoltage tripper
Rated working voltage (Ue): AC 230V, 50Hz;
Overvoltage action setting value (Uo): 280(1±5%)V;
Undervoltage action setting value: (35%-70%) Ue;
Rated insulation voltage (Ui) : 500V;
Trip characteristics: Tripper combined with NXB-63 series circuit breaker ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/20
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT HY23 Series Reverse Switch HY23-133
HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour.
Rated voltage: 380
Rated current: 30
Control Electricity ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-200
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT NXCQ contactor type mechanical emergency starter
Product Overview
NXCQ series contactor emergency start device is a product specially designed and developed for fire water supply system, with the function of manual mechanical emergency start fire pump, in line with GB/T50974-2014 "Technical Specification for Fire Water Supply and Fire Hydrant System" for manual mechanical emergency starting.
|
|
CHINT/CHINT Terminal Appliance —NXB-125G Miniature Circuit Breaker
CHINT/CHINT Terminal Appliance —NXB-125G Miniature Circuit Breaker
Rated current (In): 63A, 80A, 100A, 125A (1P, 2P);
Rated working voltage (Ue): 230V—— (1P), 400V—— (2P, 3P, 4P);
Rated insulation voltage (Ui ...
|
|
CHINT/CHINT Contactor NC11 Quota insulation voltage 690V
Introduction: CHINT/CHINT contactor NC11 is mainly used in the meter box to control the power supply system of the meter: under normal circumstances, the main contact of the contactor is kept on (that is, the main contact is normally closed at four poles, and one of the poles is used for the protection of the user's neutral line short circuit), only when the user owes ...
|
|
CHINT/CHINT NBHLE-40Y residual current action circuit breaker
NBHLE-40Y residual current action circuit breaker is suitable for AC 50Hz, rated voltage 240V, rated current to 40A in the line, play the role of overload, short circuit and leakage protection, can also be used as the line under normal conditions for infrequent on/off use.
The product conforms to IEC61009-1, GB/T 1691 ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-800
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-160
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|