Introduction: E+H/Endershaus Conductive Limit Detection Double-rod Probe 11362Z, 11362Z is a highly corrosion-resistant probe that can be used for limit level detection and overflow protection in plastic or non-conductive containers. Two-point control is also possible through the conductive vessel wall.
Features:
Various process connection options: Thread G1 1/2 A (flat thread)
Thread 1 1/2" NPT (Cone Thread)
DIN standard flanges, DN 40 – DN 200, PN 16 or PN 40, also available with tongue-and-groove flanges
ANSI standard flanges, 1 1/2" – 4", 150 psi or 300 psi, also optional clamp flanges (11362 only).
When using the Nivotester FTW325 probe for overflow protection, the EW 11Z electronic insert can be installed. Continuous monitoring of the maximum limit values of the cables.
The Series 11362Z can be used in hazardous explosion areas, wastewater treatment plant zone 0 (grease sumps), and spill protection (WHG) for water-contaminated liquids.
Product parameters
Measuring principle
Electrical conductivity
Features/Applications:
Double-rod probe with high resistance to liquid corrosion
Power/Communications
Relays
Ambient temperature
-20...80 °C
(-4...176 °F)
Process temperature
-40...150 °C
(-40...302 °F)
Process pressure (absolute)/maximum overpressure limit
Vacuum... 30 bar
(Vacuum...) 435 psi)
The minimum conductivity of the medium
20 µS/cm
The main wetted parts
PTFE, PFA, 316 TI, Alloy B/C4, Titanium, Tantalum, Monel
Process connections
G 1 1/2A
NPT1 1/2"
Flange DIN / ASME
Sensor length
0.1...4m
(4...157ft)
correspondence
Relays
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the E+H/Endershaus Conductivity Limit Detection Double Rod Probe 11362Z product, if you are interested in E+H/Endershaus Conductivity Limit Detection Double Rod Probe, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience
|
More on that
|
E+H/Endershaus Digital fluorescence dissolved oxygen sensor Memosens COS81E
Description: E+H/Endershaus digital fluorescence dissolved oxygen sensor Memosens COS81E, Memosens COS81E digital fluorescence dissolved oxygen sensor, ideal for hygienic applications.
Features:
The Memosens COS81E follows the EHEDG and ASM...
|
|
E+H/Endershaus Digital ORP Electrode Orbisint CPS12D Process pressure 16 bar
Description: E+H/Endershaus Digital ORP Electrode Orbisint CPS12D, Orbisint CPS12D is an all-rounder digital glass ORP electrode for process and environmental measurements.
Features:
The electrode adopts a large-area anti-fouling PTFE annular diaphragm, which is strong and resistant.
|
|
E+H/Endershaus Radar measures travel time principle Micropilot FMR57
Introduction: E+H/Endershaus Radar Measurement Journey Time Principle Micropilot FMR57, Micropilot FMR57 sensor meets the highest requirements for level measurement of bulk solids and is suitable for level measurement in tall silos, coal bunkers or stockpiles.
Features:
Hardware and ...
|
|
E+H Proline Promass E 200 Gas error ±.50%
Description: The E+H/Endershaus mass flow meter Proline Promass E 200 is a robust, long-term stable solution for high-precision liquid and gas measurement in standard applications in the chemical industry. The Proline E 200 is a true loop-powered two-wire flowmeter, ...
|
|
E+H/Endershaus Thermal Mass Flow Meter Proline t-mass A 150
Description: The E+H/Endershaus thermal mass flow meter Proline t-mass A 150 is designed for cost-effective measurement and simple monitoring of commonly used gases, especially in compressed air. It is the trend in sub-metrology applications, with a rugged one-piece aluminum alloy housing that uses four-wire technology ...
|
|
E+H/Endershaus turbidity sensor OUSTF10
Description: E+H/Endershaus turbidity sensors OUSTF10 OUSTF10 scattered light turbidity sensors are used to measure miscible fluids in suspended solids, emulsions and process liquids.
Features:
Accurate and highly sensitive purity monitoring for better product quality
...
|
|
E+H/Endershaus Average Thermometer Prothermo NMT81
Introduction: E+H/Endershaus average thermometers Prothermo NMT81, Prothermo NMT81 for the average temperature measurement of the medium with optional level monitoring.
Features:
Up to 24 RTDs can be installed for precise asset management
Pick up...
|
|
E+H/Endershaus Thermophant® T TTR31 range -50 – 150°C
Introduction: E+H/Endershaus Thermophant® T TTR31, modern process measurement technology needs to have the advantages of cost-effective, space-saving, reliable operation, easy installation and commissioning, this temperature switch fully meets these requirements, suitable for the safety of process temperatures.
|
|
E+H/Endershaus digital ORP electrode Memosens CPS12E with IP68 degree of protection
Description: E+H/Endershaus Digital ORP Electrode Memosens CPS12E, Memosens CPS12E is an all-rounder digital ORP electrode. Reliable measurement in harsh conditions or in hazardous locations.
Features:
Rugged and low-maintenance ORP electrodes: large ...
|
|
E+H/Endershaus mass flow meter Proline Promass O 500 liquid ± 0.0005g/cm3
Description: The E+H/Endershaus mass flow meter Proline Promass O 500 is suitable for the oil and gas industry and provides high-precision measurement of liquids and gases at the highest process pressures. The sensor is perfectly suited for offshore conditions and is resistant to stress corrosion fracture. Promass O 500's ...
|
|
E+H/Endershaus ultrasonic level sensor FMU44 temperature sensor
Product Introduction: All-in-one measuring transmitter for non-contact level measurement of liquids, slurries and lumps Pros Menu-based on-site operation with four-line plain text display for quick and easy instrument commissioning in 7 languages Field envelope display for easy instrument failure
|
|
E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FDU92 FDU92
Introduction: E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FDU92 FDU92, FDU92 ultrasonic sensors are suitable for continuous, non-contact level measurement of liquids, slurries, sludges, powders and solid lumps, maintenance-free, and can also be used for flow measurement in open channels and measuring weirs.
|
|
E+H/Endershaus digital pH sensor Orbipac CPF81D with IP68 degree of protection
Introduction: E+H/Endershaus Digital pH Probe Orbipac CPF81D, the Orbipac CPF81D is a digital pH probe that is a simple measurement solution for demanding applications.
Features:
The electrodes can be mounted in both flow-through and fixed mounting brackets
High long-term ...
|
|
E+H/Endershaus temperature transmitter iTEMP® TMT84
Introduction: The E+H/Endershaus temperature transmitter iTEMP® TMT84 offers excellent reliability, accuracy and long-term stability for critical processes in all industries, not only for the transmission of thermoresistive (RTD) and thermocouple (TC) digital conversion signals, but also for the use of PRO ...
|
|
E+H/Endershaus Bar Protector TA575 insertion depth 5 mm
Introduction: E+H/Endershaus Bar Protective Sleeve TA575, because of the harsh process conditions, the strength of the protective sleeve must be precisely calculated. Dyeing penetration test, ultrasonic test, helium leak test, pressure durability test, and various non-destructive material tests to prove the material and workmanship.
|
|
E+H/Endershaus Radar measures travel time principle Micropilot FMR54
Introduction:E+H/Endershaus Radar Measurement Travel Time Principle Micropilot FMR54, Micropilot FMR54 is mainly used for liquid level measurement in high temperature and high pressure occasions, and its specially designed flat panel antenna is especially suitable for liquid level measurement with waveguide installation.
Features:
...
|
|
E+H/Endershaus PROFIBUS gateway Fieldgate SFG500
Introduction: E+H/Endershaus PROFIBUS gateway Fieldgate SFG500, Fieldgate SFG500 provides independent access paths for access to PROFIBUS networks, and its wide range of applications is supported by various operating modes. The wide range of applications of the Fieldgate SFG500 has been ...
|
|
E+H/Endershaus Electronic Vibration Limit Detection Soliphant FTM51
Introduction: E+H/Endershaus Electronic Vibration Limit Detection Soliphant FTM51, Soliphant M FTM51 is a rugged tuning fork limit detection switch for solid fines or low-density loose solid powders in silos.
Features:
Reach IEC...
|
|
E+H/Endershaus Bar Protective Sleeve TA562 Maximum insertion depth 5 mm
Introduction: E+H/Endershaus Bar Protective Sleeve TA562, because of the harsh process conditions, the strength of the protective sleeve must be precisely calculated. Dyeing penetration test, ultrasonic test, helium leak test, pressure durability test, and various non-destructive material tests to prove the material and workmanship.
|
|
E+H/Endershaus Dissolved Oxygen Sensor Oxymax COS61 Process pressure 10 bar
Introduction: E+H/Endershaus Dissolved Oxygen Sensor Oxymax COS61, Oxymax COS61 is a high-performance dissolved oxygen sensor that provides fast, accurate and drift-free measurements.
Features:
Low maintenance requirements and wide application