Introduction: E+H/Endershaus Ammonia Analyzer Liquiline System CA80AM, Liquiline System CA80AM for high-precision ammonia nitrogen measurement at all critical control points. As part of the Liquiline platform, it is plug-and-play and easy to upgrade to a measuring station – with minimal installation requirements. Automated calibration and cleaning, as well as low reagent consumption, save on operating and maintenance costs. Advanced diagnostics with remote access ensure process safety and provide users with process documentation for easy process management.
Features:
Easy commissioning, plug & play thanks to the Memosens technology and user-friendly interface
Easy function upgrade – even to a complete measuring station – simply add and connect Memosens sensors
Advanced diagnostics with remote access for increased process safety
Automatic calibration, automatic cleaning, and an optional reagent cooling unit can effectively reduce system maintenance and management costs
Complies with standard colorimetric measuring principle - indigo method - according to ISO 7150-1, DIN 38406-5 and GB 7481-87
Product parameters
Measuring principle
Colorimetry
peculiarity
Process analyzer for ammonia nitrogen measurement in aqueous solutions
Complies with standard colorimetric measuring principle - indigo method - according to ISO 7150-1, DIN 38406-5 and GB 7481-87
Measurement method
Complies with standard colorimetric measuring principles - Indolephenol blue method according to ISO 7150-1, DIN 38406-5 and GB 7481-87
size
Cabinets
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Cabinet 1693 x 530 x 417 mm
66.65 x 20.87 x 16.42 in cabinet
devise
Open installations, cabinets, and vertical cabinets
High-performance plastic ASA-PC, with steel coating
Process temperature
4104 °F (41...104 °F)
Ambient temperature
5 to 40 °C
Process pressure
At atmospheric pressure, the absolute pressure is less than 0.2 bar
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the E+H/Endershaus Ammonia Analyzer Liquiline System CA80AM product, if you are interested in E+H/Endershaus Ammonia Analyzer, please also contact our staff, we look forward to your call, hope our technology and service can bring you a better experience
|
More on that
|
E+H/Endershaus digital pH sensor Memosens CPL51E is IP68 rated
Description: The Robust Memosens CPL51E with plastic shaft and non-contact inductive Memosens cable connection is suitable for random sampling in the field or laboratory. The pre-calibrated electrodes are plug-and-play. It is recommended to use it with the Liquiline Mobile CML18 mobile handheld device, ...
|
|
E+H/Endershaus electromagnetic flowmeter Proline Promag H 200
Description: The E+H/Endershaus electromagnetic flowmeter Proline Promag H 200 is the sensor of choice for demanding applications in the chemical and life sciences industries. Thanks to true loop-powered technology, the Promag H 200 can be seamlessly and cost-effectively integrated into existing infrastructures. Based on intrinsically safe ...
|
|
E+H/Endershaus Capacitive Limit Detection Solicap FTI77 Safety Certified SIL
Introduction: E+H/Endershaus Capacitive Limit Detection Solicap FTI77, Solicap FTI77 Semi-Insulated Sword/Cable Probe for Limit Detection of Fine and Coarse Solids
Features:
Ultra-rugged probes designed for demanding process conditions
Pass...
|
|
E+H/Endershaus analogue ORP electrode Orbipac CPF82 with IP68 degree of protection
Introduction: E+H/Endershaus Analog ORP Electrode Orbipac CPF82, Orbipac CPF82 Analog ORP Electrode is suitable for ORP measurement under harsh operating conditions.
Features:
Suitable for both flow-through and immersion installations
Long-term stability: the use of the second 3 electrolyte ...
|
|
E+H/Endershaus digital free bromine sensor Memosens CCS55D
Description: E+H/Endershaus Digital free bromine sensor Memosens CCS55D, Memosens CCS55D is a low-maintenance digital free bromine sensor. It reliably measures in desalination plants, process water, cooling water, swimming pools and fisheries, and outputs stable measurements ...
|
|
The E+H/Endershaus analogue conductivity sensor Condumax CLS13 is IP67 rated
Introduction: E+H/Endershaus Analog conductivity sensor Condumax CLS13, Condumax CLS13 is a stable conductivity sensor that can be used for the measurement of steam/water circulation systems in power plants, especially for low conductivity (high temperature and high pressure) measurements, to ensure that the process is not corroded.
|
|
E+H/Endershaus Bar Protector TA570 inserts to a depth of 5 mm
Introduction: E+H/Endershaus Bar Protective Sleeve TA570, because of the harsh process conditions, the strength of the protective sleeve must be precisely calculated. Dyeing penetration test, ultrasonic test, helium leak test, pressure durability test, and various non-destructive material tests to prove the material and workmanship.
|
|
E+H/Endershaus Tuning Fork Level Meter FTL20-032E Vibratory Compact
Product introduction: FTL20-032E is an all-in-one limit level detection switch. Typically used in tank farms, vessels and pipelines, in cleaning and filtration systems and cooling and lubrication tanks, for overfill protection or to prevent pumps from running dry. [/backcolor]
Tuning fork level gauge FTL20-032E[/ba ...
|
|
E+H/Endershaus digital non-glass pH electrode Ceramax CPS341D
Description: The E+H/Endershaus digital non-glass pH sensor Ceramax CPS341D CPS341D is a durable sensor for hygienic measuring applications in the food and life sciences sectors.
Features:
Long-term stability after years of operation
Protect...
|
|
E+H/Endershaus Guided wave radar measures travel time principle Levelflex FMP52
Introduction: E+H/Endershaus Guided Wave Radar Measuring Stroke Time Principle Levelflex FMP52, the Levelflex FMP52 uses a corrosion-resistant PFA seamless coated probe for level measurement of corrosive liquids.
Features:
Even in variable measuring products or process strips...
|
|
E+H/Endershaus Mass Flow Meter Proline Promass A 200 Maximum pressure 6250 psi
Description: The E+H/Endershaus mass flow meter Proline Promass A 200 is ideal for continuous process control under harsh conditions. The single-tube flowmeter with its unique self-emptying function enables high-precision measurement of very small flow rates of liquids and gases.
|
|
E+H/Endershaus Liquiphant FTL50
Introduction: E+H/Endershaus Liquiphant FTL50 and Liquiphant FTL50 tuning fork limit detection switches can be used in explosion hazard areas, with various international approvals, suitable for all industries.
Features:
Available for functional safety ...
|
|
E+H/Endershaus Radar Level Gauge Micropilot FMR62B
Introduction: E+H/Endershaus Radar Level Sensor Micropilot FMR62B, Micropilot FMR62B is a member of the new generation of 80 GHz radar level sensors. Continuous non-contact level measurement in demanding liquids, high temperatures, high pressures, and difficult media.
|
|
E+H/Endershaus Mass Flow Meter Proline Promass E 100 Measuring Tube 904L
Introduction: The E+H/Endershaus mass flow meter Proline Promass E 100 is a robust and proven solution for high-precision measurement of liquids and gases in standard applications. With a compact transmitter, the compact instrument has excellent performance and can be seamlessly connected to ...
|
|
E+H/Endershaus digital ORP electrode Orbipore CPS92D degree of protection IP68
Introduction: E+H/Endershaus Digital ORP Sensor Orbipore CPS92D, Orbipore CPS92D is a digital pH sensor for the measurement of fibrous media, highly solid-containing media such as suspensions, easy-to-precipitate solutions and emulsions.
Features:
Open-cell diaphragm ...
|
|
E+H/Endershaus iTEMP® TMT80 temperature transmitter
Description: The E+H/Endershaus iTEMP® TMT80 temperature transmitter, a programmable temperature transmitter for RTD and thermocouple sensors. The linearization characteristics of various sensors are stored in the transmitter to ensure the highest level of measurement accuracy. 4 - 20 mA standard current output ...
|
|
E+H/Endershaus Temperature Sensor Protective Sleeve TA414 Insertion depth 4000mm
Introduction: E+H/Enderhaus Temperature Sensor Protective Sleeve TA414, the sheath is used in conjunction with RTD (resistive) thermometers such as Enderhaus TST414 to protect the working elements from chemicals. The thermometer is secured with locking screws on the sheath tube, making it easy to replace the thermometer. Cause...
|
|
E+H/Endershaus High Temperature Thermocouple Thermometer TAF12D
Introduction: E+H/Endershaus High Temperature Thermocouple Thermometer TAF12D, the measuring point with extremely high process temperatures requires the thermometer to be equipped with a ceramic sheath tube and thermocouples made of special metals such as platinum and rhodium. The special material sheath protects the working elements during the measurement process and prevents mechanical damage or chemical damage.
|
|
E+H/Endershaus Ultrasonic Measurement of Travel Time Principle Prosonic FDU93
Introduction: E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FDU93, the FDU93 ultrasonic sensor is suitable for continuous, non-contact level measurement of liquids, slurries, sludges, powders and solid lumps, maintenance-free, and can also be used for flow measurement in open channels and measuring weirs.
|
|
E+H/Endershaus Temperature Transmitter iTEMP® TMT80 Auxiliary Power Supply 8 – 35VDC
Description: E+H/Endershaus temperature transmitter iTEMP® TMT80, a programmable temperature transmitter for RTD and thermocouple sensors. The linearization characteristics of various sensors are stored in the transmitter to ensure the highest level of measurement accuracy. 4 - 20 mA standard current output signal ...
|
|