Multi-function sensor controller handset
specification
Parent / Slave | Handset | Response time | It is specified according to the model of each connection*1 | Added a handset | Up to 4 units for 1 master machine*2 | I/O | Control the output | Up to 4 outputs | NPN open collector/PNP open collector switched | 24 V or less, | Parent unit: 50 mA or less*3, Handset: 20 mA or less | Residual voltage 2 V or less | N.O./N.C. switching | *1*4 | External inputs | Up to 5 outputs | Short-circuit current NPN: 1 mA or less / PNP: 2 mA or less | Please refer to the wiring diagram for the loading voltage (page 3 of the instruction manual) | *1*4 | Analog output | ― | Protection circuits | Power Reverse Connection Protection, Power Surge Protection, | Output overcurrent protection, output surge protection, output reverse polarity protection | power supply | Supply voltage | DC 24 V ripple (P-P) 10% or less, Class 2 or LPS | Current consumption | 55 mA or less (excluding load)*5 | Sensor Connector Specifications | The sensor is allowed to consume current | 150 mA or less | N-bus connection specifications | Allowable flow current | Below 900 mA | Environmental resistance | Ambient temperature | -20 to +50 °C (no freezing) | relative humidity | 35 to 85 % RH (non-condensing) | Earthquake resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each direction of X,Y,Z | Impact resistance | 6 times each in the 1,000 m/s2, X, Y, Z directions | Material | Housing, dust cover: Polycarbonate | Button: Polyacetal | Display: Acrylic | weight | About 70 g |
*1 Depending on the connected model, the response time and the type and number of inputs/outputs that can be used may vary.
For details, refer to the "MU-N Series User Manual" of the connected model.
*2 The number of N-bus devices that can be connected to a maximum of 5 units including the parent unit (or communication module NU series).
*3 20 mA or less (when a handset is added)
*4 For details on the assignment of "control outputs, external inputs, and analog outputs", refer to the table "Pin Placement for Power Cables" on page 3 of the instruction manual.
*5 Total 1185 mA or less: When a sensor is connected, 4 outputs (with load) are used, and a handset is added.
This article introduces the KEYENCE/KEYENCE amplifier built-in TOF laser sensor LR-T series MU-N12 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business
|
More on that
|
KEYENCE/KEYENCE Amplifier Built-in TOF Laser Sensor LR-T Series LR-TB5000CL
Detection distance: 5m M12 connector cable type Laser classification 1
specification
*1 Can be displayed from 50 to 5200.
*2 The classification by the FDA (CDRH) is based on IEC60825-1 and is implemented in accordance with the requirements of Laser Notice No. 50.
*3 I/O can be advanced from the following combinations ...
|
|
KEYENCE/KEYENCE Amplifier Built-in CMOS Laser Sensor LR-Z Series LR-ZB90CB
Threaded reflective type M12 connector type 90mm
specification
*1 Reference display value related to detection distance. If the set value is tuned, the value will be displaced. In addition, when "-99" is exceeded, the display will change to "-FF".
*2 The FDA's (CDRH) laser classification is based on ...
|
|
KEYENCE/KEYENCE amplifier built-in TOF laser sensor LR-T series MU-CC4
Power cable for MU-N series
End Shape: Cable Termination: M12 4pin Straight, Controller: Connector
Length: 0.3 m
Material: PVC (Vinyl Chloride)
Remarks: For the main unit
Weight: approx. 30 g
This article introduces the KEYENCE/KEYENCE amplifier built-in type of TOF...
|
|
KEYENCE/KEYENCE CMOS Laser Displacement Sensor Controller LK-H025
Sensor head wide type LK-H025
specification
This article introduces KEYENCE/KEYENCE CMOS laser displacement sensor controller LK-H025 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we are looking forward to your call, hope our technology ...
|
|
KEYENCE/KEYENCE Sensor Head-Controller Cable 2m CB-A2
KEYENCE Sensor Head-Controller Cable 2m CB-A2
Length: 2 m
Weight: approx. 200 g
This article introduces the KEYENCE/KEYENCE Sensor Head-Controller Cable 2m CB-A2 product, if you are interested in KEYENCE/KEYENCE products, please also contact our customers.
|
|
KEYENCE/KEYENCE Amplifier Built-in CMOS Laser Sensor LR-Z Series LR-ZB250AP
Square Reflective Cable Type 250mm
specification
*1 Reference display value related to detection distance. If the set value is tuned, the value will be displaced. Also, when "-99" is exceeded, the display will turn to "-FF".
*2 The FDA's (CDRH) laser classification is based on IEC608 ...
|
|
KEYENCE/KEYENCE PHOTOELECTRIC SENSOR WITH BUILT-IN ULTRA-MINIATURE AMPLIFIER PR-M/F SERIES PR-M51C3PL
Mini Slim Permeable M8 Connector Type 1.2m PR-M51C3PL
specification
*1 The number of control outputs for the M8 connector (3pin) type is one. If the model number ends with "D", it has an ON output when shading, and an ON output when it enters the light if it ends with "L".
Example) PR-M ...
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-MB15N1
Mini Slim Reflective Type (Background Suppression) Cable Type 15mm PR-MB15N1
specification
This article introduces the KEYENCE/KEYENCE ultra-small amplifier built-in photoelectric sensor PR-M/F Series PR-MB15N1 products, if you are interested in KEYENCE/KEYENCE products, please contact ...
|
|
KEYENCE/KEYENCE Optoelectric Sensor with Built-in Subminiature Amplifier PR-M/F Series OP-87668
Square nut for mini ultra-thin
Type: Plate nut for slender length
Applicable products: PR-M series
Number of Builts: 2 pcs
Material: SUS316L
Weight: approx. 2 g
In this article, we introduce the KEYENCE/KEYENCE OP-876 Series P-M/F Series Photoelectric Sensor with Built-in Ultra-Small Amplifier ...
|
|
KEYENCE/KEYENCE LR-X50 laser sensor
Introduction: KEYENCE/KEYENCE Laser Sensor LR-X50 Ultra-Compact Laser Sensor 90g 0.5mm
It can be installed in a variety of places:
Although it is a laser sensor, it can be ultra-small × 9.427×17mm. Can be installed in very tight spaces. Can be cut for ...
|
|
KEYENCE/KEYENCE Sensor Head Spot Type LK-H157
Sensor head wide type laser class 2 LK-H157
specification
This article introduces the KEYENCE/KEYENCE sensor head light spot type LK-H157 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we are looking forward to your call, hope our technology ...
|
|
KEYENCE/KEYENCE Optoelectric Sensors with Built-in Amplifiers PR-M/F Series OP-87666
Adjustable bracket mounts metal parts 130mm
Type: Adjustable bracket mount
Applicable products: PR series, PZ series, LR series
Length: 130 mm
Material: SUS304
Remarks: Comes with M3 screw×4, small slim type/plate nut for bracket ×1
Weight: approx. 5 ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87443
Control panel power cable (M8 4pin - loose wire) 2 m
Type: Control panel power cable
End Shape: M8 4pin - Loose wire
Length: 2 m
This article introduces the KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87443 product.
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-M51P3
Mini Slim Permeable Cable Type 1.2m PR-M51P3
specification
This article introduces the KEYENCE/KEYENCE ultra-small amplifier built-in photoelectric sensor PR-M/F SERIES PR-M51P3 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, I ...
|
|
KEYENCE/KEYENCE Pressure Sensor GP-M Series Weight 150 grams
Introduction: KEYENCE/KEYENCE Pressure Sensor GP-M Series Hydraulic Cylinder Pressure Management on Welding Machines to Prevent Molding Defects (Prevent Material Shortage and Cracks); Confirmation of degassing in the mold to prevent material shortages. Application of cleaning agent, cleaning water pressure, prevention of poor cleaning / waste ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH50(10M)
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XH50 (10M) Laser Sensor Amplifier Split Type Sensor Head (Detection Distance: 50 mm) with a cable length of 10 m
*1 Classified according to Laser Notice No. 56 in the FDA (CDRH) on the IEC60825-1 basis ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series
The new Ultra-Small pursues "Ultra-Small × Stable Detection". It can be installed in a variety of places
Green Laser × Mirror structure × Customized CMOS Sensors A new triangulation ranging system that achieves ultra-miniaturization
It can stably detect a wide range of targets, from highly reflective metals to black workpieces
...
|
|
KEYENCE/KEYENCE Photoelectric Sensors PS-N Series Cable PVC
Description: KEYENCE's ultra-miniature amplifier discrete photoelectric sensor PS-N series of small, high-power, wide-ranging sensor head options for extended sensor head cables, high environmental resistance and cable extension capabilities provide enhanced installation versatility.
...
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-FB30N3
KEYENCE/KEYENCE Photoelectric Sensor with Built-in Ultra-Small Amplifier PR-M/F Series Squared Reflective Type (Background Suppression) Cable Type 30mm PR-FB30N3
specification
In this article, we introduce the KEYENCE/KEYENCE ultra-compact amplifier built-in photoelectric sensor PR-M/F Series PR-FB30N ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor IX-360W
Sensing head 360 mm
specification
*1 X: Laser long dimension direction, Y : Laser short dimension direction
*2 Classification is based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice No. 56.
*3 When facing at the base distance. Scan mode: at the height ...
|
|