Description: The E+H/Endershaus Modular Thermocouple Thermometer TC13 is a highly modular, rugged thermometer for almost all industry applications. Compatible with all common communication protocols, the head-mounted transmitter is ready-to-use, enhancing measurement accuracy and reliability compared to directly connected sensors. A wide range of process connections, sizes, and materials provide application flexibility.
Features:
Modular design with standard junction boxes in accordance with DIN EN 50446 and customer-specified immersion lengths for maximum flexibility
The cores are highly compatible and designed in accordance with DIN 43772
The extension neck prevents the head transmitter from overheating
Short tapered/tapered ends for faster reaction times
Types of protection for use in hazardous locations: Intrinsically safe (Ex ia), non-sparking (Ex nA)
The head transmitter is easy to select: analogue outputs from 4 to 20 mA, HART®, PROFIBUS® PA, or FF fieldbus
Product parameters
Measurement accuracy
Cl. 1 according to IEC 60584
Response time
Depends on the settings
t50 = 6 s
t90 = 13 s
Maximum process pressure (static pressure)
At 20 °C: 50 bar (725 psi)
Operating temperature range
Type K:
-40...1.100 °C
(-40...2.012 °F)
Type J:
-40...750 °C
(-40...1.382 °F)
The maximum insertion depth required
up to 10,000.00 mm (393.70'')
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the E+H/Endershaus Modular Thermocouple Thermometer TC13 product, if you are interested in mass flow meter, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience
|
More on that
|
E+H/Endershaus Capacitive Limit Detection Minicap FTC260
Introduction: E+H/Endershaus Capacitive Limit Detection Minicap FTC260, Minicap FTC260 rod probe is simple and economical for solid bulk material limit level detection, especially for corrosive or large amounts of adhesion formed media. This probe is designed for lightweight, solid, ...
|
|
E+H/Endershaus sheath TWF16 with a insertion depth of 2.2mm
Introduction: E+H/Endershaus sheath TWF16, a special ceramic sheath is required for process measuring points at extremely high temperatures. The sheath made of special materials protects the sensor from mechanical and chemical damage during use and prolongs its service life. As a result: savings in measurement ...
|
|
E+H/Endershaus sheath tube iTHERM TT411 insertion depth 4000 mm
Introduction: The E+H/Endershaus sheathed tube iTHERM TT411 is ideal for hygienic or sterile pipes, vessels or tanks with very small immersion depths. It meets the requirements of the thermometer in terms of physical and chemical influences that need to be strengthened protection, is the replacement of working elements in the closed process, requires routine ...
|
|
E+H/Endershaus Electromagnetic Flowmeter Proline Promag L400
Description: The E+H/Endershaus electromagnetic flowmeter Proline Promag L400 is suitable for use in the water and wastewater industry. Its unique loose flange process connection facilitates flexible and easy installation. The Promag D 400 is equipped with a powerful transmitter for the water and wastewater industry ...
|
|
E+H/Endershaus Ultrasonic Level Meter FMU41 4-20 mA HART
Product Introduction: All-in-one measuring transmitter for non-contact level measurement of liquids, slurries and lumps Pros Menu-based on-site operation with four-line plain text display for quick and easy instrument commissioning in 7 languages Field envelope display for easy instrument troubleshooting ...
|
|
E+H/Endershaus Guided Wave Radar Measuring Travel Time Principle Levelflex FMP56
Introduction: E+H/Endershaus Guided Wave Radar Measuring Journey Time Principle Levelflex FMP56, Levelflex FMP56 is designed for level measurement in solid storage silos or storage tanks.
Features:
Even under variable measuring products or process conditions, ...
|
|
E+H/Endershaus analogue total chlorine sensor CCS120
Introduction: E+H/Endershaus Analog Total Chlorine Sensor CCS120, CCS120 Analog Sensor for Standard Measurement of Total Chlorine. Even in the event of flow or conductivity fluctuations, reliable measured values are transmitted, the disinfection loop is controlled, and the water is free of bacteria. At the same time, sensor calibration and ...
|
|
E+H/Endershaus Capacitive Limit Detection Solicap FTI77 Safety Certified SIL
Introduction: E+H/Endershaus Capacitive Limit Detection Solicap FTI77, Solicap FTI77 Semi-Insulated Sword/Cable Probe for Limit Detection of Fine and Coarse Solids.
Features:
Ultra-rugged probes designed for demanding process conditions
Open...
|
|
E+H/Endershaus Mass Flow Meter Proline Promass 40E Measuring Tube 904L
Introduction: The E+H/Endershaus mass flow meter Proline Promass 40E has earned a good reputation for its cost-saving use of the Coriolis principle. The flow meter with integrated Promass 40 transmitter is suitable for low-end measurement applications, providing high-precision liquid and gas flow measurement, ...
|
|
E+H/Endershaus pH electrode Memosens CPS91E is IP68 rated
Description: E+H/Endershaus pH electrode Memosens CPS91E, Memosens CPS91E with Memosens 2.0 digital technology supports extended data storage, service predictive maintenance and IIoT IIoT.
Features:
Reliable measurement of heavily contaminated media: open-hole ...
|
|
E+H/Endershaus Bar Protector TA557 inserts to a depth of 5 mm
Introduction: E+H/Endershaus Bar Protective Sleeve TA557, because of the harsh process conditions, the strength of the protective sleeve must be precisely calculated. Dyeing penetration test, ultrasonic test, helium leak test, pressure durability test, and various non-destructive material tests to prove the material and workmanship.
|
|
E+H/Endershaus Electromagnetic Flowmeter Proline Promag 10D Medium temperature 0...+60 °C
Description: The E+H/Endershaus electromagnetic flowmeter Proline Promag 10D has a clamp-on design for use in very confined spaces. It is the first choice for basic applications in the water industry. In combination with the cost-effective Promag 10 transmitter, the Promag 10D is the perfect solution for liquid measurement in a wide range of applications.
|
|
E+H/Endershaus Mass Flow Meter Dosimass Maximum process pressure PN40
Description: E+H/Endershaus Dosimass mass flow meter for flow measurement during dosing and bottling. Volumetric and mass flow with temperature and density compensation can be directly measured to ensure maximum repeatability. Dosimass is suitable for measurement occasions where space is limited, and it is a system ...
|
|
E+H/Endershaus Capacitive level measurement Liquicap FMI52 IEC 61508 standard
Introduction: E+H/Endershaus Capacitive Level Measurement Liquicap FMI52, Liquicap FMI52 is a reliable fully insulated probe for continuous level measurement of liquids, especially in small storage tanks, adhesion forming media and in extreme high temperatures.
|
|
E+H/Endershaus Smartec CLD134 compact conductivity measuring instrument
Description: E+H/Endershaus The Smartec CLD134 is a compact conductivity measuring instrument for the food, beverage and life sciences sectors. The compact design of the integrated sensors and transmitters is interference-free and easy to use. System...
|
|
E+H/Endershaus Electronic differential pressure transmitter Deltabar FMD72 process pressure 160 bar
Description: E+H/Endershaus Electronic differential pressure transmitter Deltabar FMD72 electronic differential pressure measuring system is used to measure the pressure, level, volume or mass of liquids in pressure vessels or distillation columns/evaporators. The high-pressure side sensor (HP) measures the hydrostatic pressure of the liquid, and the low-pressure side sensor (LP) ...
|
|
E+H/Endershaus Gauge Pressure Sensor Cerabar PMC51 Range: 100mbar – 40bar
Description: The E+H/Endershaus gauge pressure sensor Cerabar PMC51 digital pressure transmitter with oil-free capacitive ceramic measuring cell, mainly used in the process and hygiene industries, measures the pressure, level, volume and mass of liquids and gases. The PMC51 uses a vacuum-resistant ceramic diaphragm ...
|
|
E+H/Endershaus Thermal Mass Flow Meter Proline t-mass I 300 is IP66/67 rated
Introduction: E+H/Endershaus Thermal Mass Flow Meter Proline t-mass I 300, t-mass I uses a patented sensor design and is inserted into the pipe for mass flow measurement based on the thermal principle with ultra-high measurement stability.
Features:
Flexible settings, ...
|
|
E+H/Endershaus analogue pH electrode Orbipac CPF81 with IP68 degree of protection
Introduction: E+H/Endershaus Analog pH Sensor Orbipac CPF81, the Orbipac CPF81 is an analog sensor that is a simple solution for measurement under harsh operating conditions.
Features:
Suitable for both flow-through and immersion installations
Long-term stability: ...
|
|
E+H/Endershaus Oil Leak Detector Transmitter NRR261
Introduction: E+H/Endershaus Oil Leak Detector Transmitter NRR261, an outdoor-mounted transmitter that outputs a relay contact signal from a NAR300 float sensor.
Features:
Outdoor-mounted transmitter with output relay contact signal, from NAR ...
|
|