Amprobe IRC-120 Thermal Imaging Camera, Designed for Experts! With point-to-shoot capabilities, it provides you with a visual heatmap image to quickly and accurately identify temperature-related issues. Diagnose and troubleshoot electrical connections, motors, HVAC, and electrical faults, as well as insulation leaks around the building, and identify potential opportunities for energy savings. Both the IRC-120 and IRC-100 series are equipped with upgraded features: data storage, laser pointer, flashlight and UV lamp.
5-in-1: UV lamp, flashlight, IR temperature, thermal image, and laser pointer
• Five UV LEDs detect fluorescent pigment leakage*
• Laser pointer indicates the center of the UV region
• Bright flashlight illuminates dark areas
• Storage function to save heat images
• Infrared heatmaps are mixed in 0%, 25%, 50%, 75% and 100% modes
• Three selectable color palettes (grayscale, heat, and rainbow)
• Center point temperature measurement
• Focus-free
• Infrared temperature measurement point distance ratio of 20:1
• Circular/point/center point laser aiming
• The emissivity is adjustable from 0.10 to 1.00
• Auto-shutdown function
• Selectable °F and °C
• On-screen menus and settings can be intuitively navigated via joystick
• Hot and cold markers instantly identify the hottest, coldest spots
• Tripod mounts
Technical Indicators
features | IRC-120 | Ultraviolet lamp | 5 blue LEDs | flashlight | 4 LEDs | Laser aiming | Round/spot/center point lasers have an output of <1 mW at a wavelength of 650 nm | Temperature measurement | Yes, the center point | Temperature range | 14 °F to 932 °F (-10 °C to 500 °C) | IR accuracy (ambient temperature of 23° C ± 2° C | ≥ 32 °F (≥ 0 °C): ± 4 °F (± 2 °C), or ± 2 % of reading, whichever is greater < 32 °F (< 0 °C): ± 6 °F (± 3 °C) | Display resolution | 0.2 °F / 0.1 °C | Infrared repeatability | ± 0.8 % of reading or ± 2 °F (± 1 °C), whichever is greater | Temperature coefficient | 0.1 °C/°C or ± 0.1 %/°C of reading, whichever is greater | Object distance ratio | 20:1 | Minimum measurement target object size | 8 mm | Response time (95%) | < 125 ms | Spectral response | 8 μm to 14 μm | Emissivity | Numerically adjustable from 0.10 to 1.00 in 0.01 increments | Visual image (overlaid with infrared heatmap) | Five blending modes (0%, 25%, 50%, 75%, and 100%) | Visual image resolution | 16,384 pixels (128 x 128 pixels) (interpolated pixels) | Infrared detector resolution | 32 x 32 pixels | visual field | 33 ° x 33 ° | Heat sensitivity | 150 mK | Focusing system | Fixed focal length | Image color palette | Grayscale (white heatmap), hot iron, and rainbow maps | Hot and cold markings | be | Center point marker | be | display screen | 128 x 160 pixel 1.77-inch color TFT display | Data storage | Stored image size: 124 x 160 pixels Image file size: Typical 40 KB Maximum stored image file name: 9999 | Operating temperature and humidity | 32 °F to 122 °F (0 °C to 50 °C) Relative humidity of 10 to 90 % at 86 °F (30 °C) without condensation | Storage temperature | -4 °F to 140 °F (-20 °C to 60 °C) without batteries | Visual to IR effective image alignment | ≥ 18 inches (45 cm) for best results at 1 meter | The laser is aimed at the center of the visual image | ≥ 18 in (45 cm) (typical) | The laser is aimed at the ultraviolet field | Approx. 18 inches (45 cm) (typical) | working and storing altitude | < 6561 ft (< 2,000 m) | Drop resistant | 4 ft (1.2 m) | Vibration and shock | IEC 60068-2-6, 2.5g, 10 to 200 Hz, IEC 60068-2-27, 50g 11ms | power supply | Three (3) 1.5 V AA IEC LR6 alkaline batteries | Battery life | 8 hours with monitor on (typical) Power consumption: 220 mA (typical) | Automatic power off | Selectable modes: Off, 1 minute, 2 minutes, 5 minutes, and 10 minutes | Agency Certifications | | Laser safety compliance | IEC 60825-1, Class 2 |
Electromagnetic compatibility | EN 61326-1
Korea (KCC): Class A equipment (industrial broadcasting and communication equipment)[1]
[1] This product complies with the requirements of industrial (Class A) electromagnetic wave equipment, and the seller or user should pay more attention. This device is intended for use in a commercial environment and is not intended for domestic use. | Dimensions (H x W x L) | 7.3 x 2.1 x 4.1 in (185 x 54 x 104 mm) | weight | Approx. 0.64 lbs (0.29 kg) | We will provide customers with high-quality products and satisfactory services with honest and trustworthy, convenient and fast business methods and strict management.
This article introduces the Fluke/Fluke IRC-120 thermal imaging camera products, if you are interested in Fluke/Fluke products, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Fluke/Fluke 287C True RMS Electronic Recording Multimeter
The Fluke 287/CN True RMS Electronic Record Multimeter with trend capture quickly documents design performance and graphically displays what is happening. With its unique recording and graphing capabilities, users no longer have to download recorded readings to a PC to analyze trends. Fl ...
|
|
Fluke/FLUKE CV200ClirVu®50 mm (2 in) IR window
The plating – exclusive to Fluke's IR window – seals the optics prior to assembly to protect them from moisture, making them ideal for use in both high and low temperature environments.
Each Fluke IR window is delivered with a nameplate marked with a unique field number for quick location and ...
|
|
FLUKE 12E+ DIGITAL MULTIMETER
Support AC and DC voltage, AC and DC millivolt, AC and DC microampere/milliampere/ampere, resistance, capacitance and other tests. One-handed operation, easy to use.
Electronic measurement basic function coverage
Voltage, current, capacitance, and resistance are possible
and unique temperature and frequency functions
Temperature measurement with ease ...
|
|
Fluke/Fluke 1630-2 FC Earth Loop Resistance Test Clamp Meter
Test the ground resistance of equipment located in tight spaces (including indoors or areas where auxiliary grounding electrodes are not allowed). Stay Online - Identify ground loop resistors without having to disconnect and reconnect the ground electrode from the system.
Fluke 1630-2 FC Ground Loop Resistance Test Clamp Meter
|
|
Fluke/Fluke 54-IIB Dual Channel Recording Contact Thermometer 400g
Introduction: The Fluke/Fluke 54-IIB Contact Thermometer (Thermocouple Thermometer) provides laboratory-grade accuracy (± [0.05% + 0.3°C]) with reliable readings. The Fluke 54-IIB is a dual-channel thermometer that comes standard with two 80PK-1 K thermocouples for multi-point ...
|
|
FLUKE/FLUKE F945 NOISE METER
The Fluke 945 noise meter measures ambient noise (A-weighted): 30 to 130 dB, 0.1 dB resolution, and ± 1.5 dB accuracy
Measure mechanical noise (C-weighted): 35 to 130 dB, 0.1 dB resolution, accuracy ± 1.5 dB
Frequency response range: 31.5 Hz to 8 kHz
Temperature coefficient ...
|
|
FLUKE LIQ-100 SMART LINK
LinkIQ is capable of measuring lengths up to 1000 feet (305 meters) and provides distance to fault locations such as open, short, and non-terminated cables. Remote IDs can be used for a complete cable pair wiring diagram to help identify miswires and strings. The main cable testing function of LinkIQ is the ...
|
|
Fluke/FLUKE Phasor Calibration System 6135A/PMUCAL
Fast, automatic, traceable, and fully compliant calibration system in accordance with IEEEC37.118.1TM-2011
Today's smart grids rely on phasor meters (PMUs) to provide vital real-time grid voltage, current, frequency, and phase data. In order to ensure that the PMU can provide a continuous and stable ...
|
|
Fluke 1750 Three-Phase Power Quality Recorder
Use the new Fluke 1750 Three-Phase Power Quality Recorder and Fluke Energy Analysis Software to record three-phase power quality and monitor power quality fluctuations. These energy meters work around the clock and automatically record every power quality parameter and event in every cycle.
apply
Long-term ...
|
|
FLUKE Fluke iSee™ Thermal Camera - TC01A
Description: FLUKE iSee™ Thermal Imaging Camera - TC01A 256 x 192 pixel 25Hz frame rate ±2% or ±2 °C accuracy
Key features:
256 x 192 pixels for a detailed image experience
High temperatures of up to 550 °C cover a wide range of applications
±2% ...
|
|
Fluke/FLUKE 712C RTD Calibrator Weight 515 g
Summary: The Fluke/Fluke 712C RTD Temperature Calibrator is an easy-to-use, highly accurate, and single-function test tool that is ideal for temperature calibration professionals.
Features:
The 712C is capable of measuring and ...
|
|
Fluke/Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator
Simple, powerful, intrinsically safe calibration tool
The new 725Ex Intrinsically Safe Multifunction Process Calibrator is powerful and easy to use. Together with one of the new Fluke-700PEx pressure modules (8 units), the 725Ex is capable of calibrating maintenance-required processes used in almost any area where explosive gases are present ...
|
|
Fluke 87V MAX Digital Multimeter Weight 698.5 g
Introduction: The Fluke/Fluke 87V MAX digital multimeter features an industrial-strength case and a removable holster. The holster doubles as a test probe holder for easy one-handed operation. Withstands drops of up to 4 m (13 ft) and comes with an industrial-strength case and holster.
...
|
|
Fluke/FLUKE 87V Industrial True RMS Digital Multimeter
Greatly improved measurement capabilities, diagnostics, resolution, and accuracy
Fluke 87V Industrial True RMS Digital Multimeter
The newly launched Fluke 87V/C greatly improves measurement capabilities, diagnostic functions, resolution, and accuracy, enabling more solutions for motor drives, factory automation equipment, ...
|
|
Fluke/Fluke TiS75+ Thermal Imaging Camera 384*288 pixels
Summary: The Fluke TiS75+ thermal imaging camera has 44%* more pixels* than the original model, which will provide users with clearer and more accurate measurements. And the thermal sensitivity is upgraded at the same time, which can detect even the smallest temperature changes.
...
|
|
Fluke/Fluke DSX-5000 Cable Analyzer
DSX reduces the time required to repair cabling faults with easy-to-use, dedicated diagnostic tools
Meets the recommended ISO (IEC WG9 Standard IEC61935-1) Level V to meet 1000 MHz accuracy requirements, supporting the full set of resistance unevenness required for Power over Ethernet (PoE) ...
|
|
FLUKE 279FC Thermal Imaging Digital Multimeter
The 279 FC is a full-featured digital multimeter with integrated thermal imaging designed to increase your productivity and confidence. Thermal multimeters help you quickly find, repair, inspect and report many electrical problems, giving you confidence that they have been resolved.
Thermal imaging multimeter ...
|
|
Fluke/Fluke Compact MI3 infrared thermometer
The Fluke Compact MI3 infrared thermometer represents a new generation of performance and innovation in continuous non-contact temperature monitoring and is widely used in OEM applications and manufacturing processes. The MI3 infrared thermometer is composed of two parts: a miniature sensing head and an independent communication electronic system.
|
|
Fluke 107 fully automated, high-precision handheld digital multimeter
The Fluke 107 Digital Multimeter is Fluke's new handheld multimeter and is designed to be the same size as the palm size, but this series of multimeters has the best safety in its class and is designed to meet the needs of your work! All factors considered, the 107's multimeter is completely beyond you ...
|
|
Fluke 107 Pocket Digital Multimeter Weight 200g
INTRODUCTION: THE FLUKE/FLUKE 107 DIGITAL MULTIMETER IS DESIGNED TO MEET THE NEEDS OF YOUR WORK! This digital multimeter is designed to be operated in the palm of your hand, regardless of your workplace.
Features:
Devise...
|
|