KEYENCE/KEYENCE Laser Sensor Amplifier Discrete Amplifier M8 Connector Type Main Unit LR-XN11C
Model | LR-XN11C | type | NPN Output/PNP Output (Switched Output) | Cables/connectors | M8 connector*1 | Main Unit/Extended Unit | Main unit (additional units are not supported) | Control the number of outputs | 2*2 | Number of external inputs | 1*2 | Response time | 500 μs*3 / 1 ms / 3 ms / 10 ms / 200 ms switchable | IO-Link | Specification v1.1/COM2 (38.4kbps) | function | Timer function | Timer Disable / Off Delay / On Delay / Single Pulse / On - Off Delay / Turn on Single Delay | Input and output | Control the output | Open collector 30 VDC or less, N.O. / N.C. switchable | 1 Output maximum 100 mA or less / 2 Total output 100 mA or less | Residual voltage NPN: 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA), PNP: 1.6 V or less (output current 10 mA or less) / 2.2 V or less (output current 10 to 100 mA) | External inputs | External Set Input / Illumination Stop / Zero Input / Reset Hold / Orientation Alarm Contact Switching | Short-circuit current NPN: 1 mA or less, PNP: 2 mA or less | Input time: 3 ms ON or more, 20 ms or more OFF (25 ms ON or more, 25 ms or more OFF only when tuning is selected) | Expansion units were added | — | Protection circuits | Power supply reverse polarity protection, output overcurrent protection, output surge protection, output reverse polarity protection | Number of anti-jamming units | — | power supply | Supply voltage | 16 to 30 VDC*4 (including ripple (P-P) 10% or less), class2 | Power consumption | Typical: 1150 mW (47 mA at 24 V, 64 mA at 16 V), 985 mW at ON and ALL (40 mA at 24 V, 53 mA or less at 16 V) (except load current) | Environmental resistance | Use ambient temperature | -20 to +55°C (no freezing)*5 | Humidity of the working environment | 35 to 85% RH (non-condensing) | Vibration resistance | 10 to 500 Hz power spectral density: 0.816G2/Hz X, Y, Z direction | Impact resistance | 500 m/s2 (50 G) X, Y, Z 3 times in each direction | Housing material | Main unit, cover: Polycarbonate | annex | Instruction manual | weight | About 22 g | *1 The power cable length of the M8 connector type is 30 m or less. When connecting IO-Link, keep it to less than 20 m.
*2 Output 2 and external input are switched.
*3 When 500 μs is selected, the following limits are specified.
· Tuning is limited to 2-point tuning.
· The detection range shield is set during tuning. (Manual setting of the shielding range is not supported)
· Output 2 is limited to the output of alarms such as errors and orientation monitoring, and no standard/zone can be used.
· The anti-interference function is not supported
*4 When adding more than 4 expansion units, set the supply voltage to 20 V or more.
*5 -20 to +55°C for 1 to 2 units, -20 to +50°C for 3 to 10 units, -20 to +45°C for 11 to 16 units
This article introduces the KEYENCE/KEYENCE laser sensor LR-X series LR-XN11C products, if you are interested in KEYENCE/KEYENCE sensor, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-B03
Mini slim metal parts are installed as standard
Type: Small, slender standard mounting bracket
Number of Builts: 1pcs
Material: SUS316L
Remarks: Comes with M3 screw×2, plate nut
Weight: approx. 8 g
This article introduces the KEYENCE/KEYENCE subminiature amplifier built-in photoelectric transmitter ...
|
|
KEYENCE/KEYENCE Clamp-on Flow Meter FD-R Series DC200mA
Introduction: KEYENCE/KEYENCE Clamp Flow Meter FD-R Series No impact on production during installation, no expertise, no tools or contractors required, no risk of contamination, leakage or pressure loss, installation in minutes using a standard screwdriver, built-in predictive maintenance procedures.
...
|
|
KEYENCE/KEYENCE Sensor Head LJ-V7020
KEYENCE Sensor Head LJ-V7020 Reference distance: 20 mm
Output 10 mW
Ambient temperature 0 to +45 °C*11
Material: Aluminum
Weight approx. 410 g
*1 The W polarization function cannot be used.
*2 Please do not use optical devices (e.g. binocular magnifiers, magnifiers, displays, etc.).
|
|
KEYENCE/KEYENCE Optoelectric Sensor with Built-in Amplifier PR-M/F Series OP-87664
Adjustable relay metal fittings
Type: Adjustable trunk mount
Applicable products: PR series, PZ series, LR series
Material: Zinc nickel plated, others
Weight: approx. 190 g
In this article, we introduce the KEYENCE/KEYENCE UV-miniature amplifier built-in photoelectric sensor PR-M/F series ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-X250CG (Detection Distance: 250mm)
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-X250CG Laser Sensor Standard M8 Connector Metal Sheathed Cable Type (Detection Distance: 250mm)
*1 The cable length of the M8 connector type is 30 m or less. When connecting IO-Link, keep it to less than 20 m.
...
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-B05
Mini slim side-mounted metal parts
Type: Small slender side mount
Number of Builts: 1pcs
Material: SUS316L
Remarks: Comes with M3 screw×2, plate nut
Weight: approx. 10 g
This article introduces the KEYENCE/KEYENCE ultra-small amplifier built-in photoelectric sensing ...
|
|
KEYENCE/KEYENCE photoelectric sensor PZ-M series control output 100mA
Introduction: KEYENCE's stand-alone photoelectric sensor PZ-V/M series uses a laser sensor with distance principle detection, which is not easily affected by the color and tilt of the workpiece, and performs stable detection. Unaffected by highly reflective target backgrounds, it is highly resistant to dust and dirt.
...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87458
Ethernet cable (M12 4pin-RJ-45) NFPA79 standard standard cable 5 m
Type: NFPA79 standard Ethernet cable
End shape: M12 4pin-RJ-45
Length: 5 m
This article introduces the KEYENCE/KEYENCE multi-point laser sensor OP-87458 ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87459
Ethernet cable (M12 4pin-RJ-45) NFPA79 standard standard cable 10 m
Type: NFPA79 standard Ethernet cable
End shape: M12 4pin-RJ-45
Length: 10 m
This article introduces the KEYENCE/KEYENCE multi-point laser sensor OP-8745 ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87903
Sensor head cable 2 m
Type: Sensor head-to-amplifier cable
Length: 2 m
Weight: approx. 110 g
This article introduces the KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87903 product, if you are interested in KEYENCE/KEYENCE products, please also contact our ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XN11P
KEYENCE/KEYENCE Laser Sensor LR-X Series LR-XN11P Laser Sensor Amplifier Split Amplifier Cable Type Main Unit PNP
*1 When 500 μs is selected, the following limits are specified.
· Tuning is limited to 2-point tuning.
· The detection range is set during tuning.
|
|
KEYENCE/KEYENCE CMOS Laser Displacement Sensor Controller LK-G5001
KEYENCE/KEYENCE CMOS Laser Displacement Sensor Controller LK-G5001
specification
This article introduces KEYENCE/KEYENCE CMOS laser displacement sensor controller LK-G5001 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, I ...
|
|
KEYENCE/KEYENCE Photoelectric Sensor with Built-in Subminiature Amplifier PR-M/F Series OP-87673
Slit plate 0.5×3 mini ultra-thin
Type: Slender Small, slender and elongated
Number of Builts: 1pcs
Slit plate size: 0.5×3
Material: SUS304
Remarks: ・Detection distance: 180mm (when both transmitter and receiver sides are attached) ・Transmission type only
Weight: approx. 1 g
This paper...
|
|
KEYENCE/KEYENCE CMOS Laser Displacement Sensor Controller LK-H020
Sensor head spot type LK-H020
specification
This article introduces KEYENCE/KEYENCE CMOS Laser Displacement Sensor Controller LK-H020 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we are looking forward to your call, hope our ...
|
|
KEYENCE/KEYENCE Fiber Optic Sensor FS-N40 Series NPN Output
Description: The KEYENCE/KEYENCE Fiber Optic Sensor FS-N40 series features the latest high-brightness LEDs and a highly efficient circuit design to dramatically increase light intensity. In the case of testing workpieces with poor environmental hygiene conditions or low reflectivity, etc., it can ensure long-term ...
|
|
KEYENCE/KEYENCE Amplifier Built-in TOF Laser Sensor LR-T Series
Reflective laser sensors with detection distances of up to 5 meters and installation restrictions. The distance detection principle is not affected by the surface of the object, and can detect a variety of workpieces.
Excellent detection capabilities
The LR-T series offers a variety of innovative features to detect targets previously thought undetectable. ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series Adjustable Bracket Fixing Screw OP-88503
KEYENCE Laser Sensor LR-X Series Adjustable Bracket Set Screw OP-88503
Shape: Adjustable bracket fixing screw (65 mm) for LR-X/LR-XH
Material: SUS316L etc
Weight: approx. 21 g
This article introduces the KEYENCE/KEYENCE laser sensing ...
|
|
KEYENCE/KEYENCE Flow Sensor FD-M Series has a pressure resistance of 2.0 MPa
Introduction: KEYENCE/KEYENCE Flow Sensor FD-M Series The FD-M Series uses Faraday's law to determine the flow rate of conductive liquids. A typical electromagnetic flow sensor uses electrodes that are in contact with the liquid inside the test tube to detect the electromotive force of the liquid. The FD-M series is determined by electrostatic capacitance ...
|
|
KEYENCE/KEYENCE Sensor Head LJ-V7300
Installation Status: Diffuse
Reference distance: 300 mm
Enclosure Rating: IP67 (IEC60529)*8
Ambient light: Incandescent lamp: 10,000 lux*9 max
Ambient temperature: 0 to +45 °C*10
Relative humidity: 85%RH or less (non-condensing)
Seismic resistance: 1 ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87457
Ethernet cable (M12 4pin-RJ-45) NFPA79 standard standard cable 2 m
Type: NFPA79 standard Ethernet cable
End shape: M12 4pin-RJ-45
Length: 2 m
This article introduces the KEYENCE/KEYENCE multi-point laser sensor OP-87457 ...
|
|