Introduction: KEYENCE/KEYENCE Clamp Flow Meter FD-R Series No impact on production during installation, no expertise, no tools or contractors required, no risk of contamination, leakage or pressure loss, installation in minutes using a standard screwdriver, built-in predictive maintenance procedures.
Features:
Simple installation: no downtime required
Suitable for a wide range of applications: water, deionized water, oils, chemicals, consumer goods, etc
Significant reduction in time and costs: no impact on production during installation
Product parameters
Model
| FD-R50
| FD-R80
| FD-R125
| FD-R200
| Supported pipeline diameters
| 1 1/2" (40A), ø44 to ø55
2" (50A), ø55 to ø64
| 2 1/2" (65A), ø64 to ø83
3" (80A), ø83 to ø100
| 4" (100A), ø100 to ø127
5" (125A), ø127 to ø152
| 6" (150A), ø152 to ø191
8" (200A), ø191 to ø220
| Supported pipeline materials
| Metal pipes, resin pipes*1
| Supported fluids
| All liquids (water, oil, medicines, etc.)*1
| Supported fluid temperatures
| -20 to +120 °C (no freezing on the surface of the line)*2
| Rated flow range
| Rated flow range: 5.0 m/s
Flow Conversion Value:
1 1/2" (40A) : 400 L/min、24 m3/h
2" (50A) : 600 L/min、36 m3/h
| Rated flow range: 5.0 m/s
Flow Conversion Value:
2 1/2" (65A) : 1000 L/min、60 m3/h
3" (80A) : 1500 L/min、90 m3/h
| Rated flow range: 5.0 m/s
Flow Conversion Value:
4" (100A) : 2500 L/min、150 m3/h
5" (125A) : 3700 L/min、220 m3/h
| Rated flow range: 5.0 m/s
Flow Conversion Value:
6" (150A) : 5500 L/min、330 m3/h
8" (200A) : 9500 L/min、570 m3/h
| Zero incision flow rate
| Zero incision: 0.3 m/s (default)*3
Flow rate converted value: 36 L/min, 2.4 m3/h
| Zero incision: 0.3 m/s (default)*3
Flow rate conversion value: 90 L/min, 5.4 m3/h
| Zero incision: 0.3 m/s (default)*3
Flow rate tariff: 220 L/min, 12 m3/h
| Zero incision: 0.3 m/s (default)*3
Flow rate tariff: 570 L/min, 36 m3/h
| How it is displayed
| 2-segment 5-digit display using white 14-segment LEDs, large status indicator, output indicator, stability indicator, unit indicator
| Displays the refresh period
| Approx. 3 times/sec
| Display resolution
| 0.1/1 (L/min)
| 1 (L/min)
| Response time
| 0.5 s/1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
| Measurement accuracy
| 20 to 100 % of F.S.: ±2.0 % of RD*4*5
6 to 20 % of F.S.: ±0.4 % of F.S.*4*5
| Zero-point error
| ±0.5 % of F.S.*4*6
| lag
| Variable
| Flow Units
| L/min、m3/h
| Integrated flow device display
| 1/10/100/1000/10000 (L)
| Piping temperature detection accuracy
| ±3 °C (piping temperature -20 °C to +50 °C), ±5 °C (piping temperature 50 °C to 120 °C)
(at ambient temperature 25 °C)*4
| Wiring specifications
| power supply
| Selectable DC Power Supply: M12 4pin Connector/AC Power Supply: M4 Screw Terminal Block
| I/O
| When using DC power: M12 4pin connector / When using AC power: M3 screw terminal block
| Inputs/Outputs (Optional)
| Output (Channel 1 / Channel 2)
| Control output/Cumulative pulse output/Error output/Temperature alarm NPN/PNP setting switching
Open collector output 30 VDC or less Maximum 100 mA/ch or less Residual voltage 2.5 V or less*7
| Analog output (channel 2)
| Flow Analog Output/Temperature Analog Output Switchable 4 to 20 mA/0 to 20 mA Load resistance 500 Ω or less*7
| External Input (Channel 2)
| Cumulative Reset Input/Zero Flow Input/Zero Adjustment Input (Switchable)
The short-circuit current is 1.5 mA or less, and the input time is 20 ms or more*7
| Protection circuits
| Power supply reverse polarity protection, power surge protection, short-circuit protection for each output, surge protection for each output
| rated
| Supply voltage
| 20 to 30 VDC incl. ripple (P-P) 10 % Class2/100 to 240 VAC -15 %/+10 % (50/60 Hz)
| Current consumption
| 200 mA or less (without load current) / 400 mA or less (including load current) when using DC power supply
Below 15 VA when using AC power supply
| Environmental resistance
| Enclosure protection grade
| IP65/67 (IEC60259) 、IP69K (ISO20653) 、Enclosure Type 4X (NEMA250)
| Ambient temperature
| -20 to +60 °C (no freezing)*2
| relative humidity
| 5 % to 90 %RH (non-condensing)
| Earthquake resistance
| 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in X, Y, Z directions
| Impact resistance
| 100 m/s2, 16 ms pulses, 1000 pulses each in the X, Y, Z directions
| Dimensions
| Body unit dimensions: 218.5 mm x 66.9 mm x 70.7 mm
| Material
| Ontology unit
| Body: Cast Aluminum + Coating/PPS, Display: Tempered Glass, Connector Part: SUS304 Equivalent
| The back of the unit
| Special rubber
| Top/bottom bracket
| SUS304
| weight
| Main unit: approx. 1.0 kg
Top/bottom bracket: approx. 1.5 kg (with separator)
| Main unit: approx. 1.0 kg
Top/bottom bracket: approx. 2.0 kg (with separator)
| Main unit: approx. 1.0 kg
Top/bottom bracket: approx. 2.3 kg (with separator)
| Main unit: approx. 1.0 kg
Top/bottom bracket: approx. 2.5 kg (with separator)
|
This article introduces the KEYENCE/KEYENCE clamp-on flowmeter FD-R series products, if you are interested in KEYENCE/KEYENC flowmeter, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-31
Fiber Optic Unit Reflective FU-31
The direction in which the light is emitted: Sideways
Fiber optic device length: 2m free cut
Diameter of the fibre optic unit: ø1.0×2
Minimum bending radius: R10 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient temperature: -40 to ...
|
|
KEYENCE/KEYENCE Amplifier Built-in CMOS Laser Sensor LR-Z Series LR-ZB250AN NPN Output Cable Exit Type (2m)
Reflective sensor with through-beam stability. It is not affected by the surface color, material, inclination, etc. of the workpiece. 316L stainless steel body shell, protection grade IP68/69K, can be used in various occasions.
Launched high-power type
Using the traditional* reflective transmission method that detects with light intensity...
|
|
KEYENCE/KEYENCE Amplifier Unit NPN EX-V01
Control Inputs: NPN Open Collector or No Voltage Contact Input (Timing Input, Reset Input, Auto-Zero Input, Judgment Output Cancellation Input, Synchronous Input, External Set Input)
Control the output
Tolerance setting: Upper/lower limit 2-level setting × 4 styles ( optional ...
|
|
KEYENCE/KEYENCE Optoelectric Sensor with Built-in Amplifier PR-M/F Series OP-87665
Adjustable bracket mounts metal parts 200mm
Type: Adjustable bracket mount
Applicable products: PR series, PZ series, LR series
Length: 200 mm
Material: SUS304
Remarks: Comes with M3 screw×4, small slim type/plate nut for bracket ×1
Weight: approx. 7 ...
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-M51CN
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series Mini Slim Permeable Type M8 Connector Type 1.2m
specification
This article introduces the KEYENCE/KEYENCE ultra-miniature amplifier built-in photoelectric sensor PR-M/F series.
|
|
KEYENCE/KEYENCE CMOS Laser Displacement Sensor IL-S065
keyence CMOS Laser Displacement Sensor IL Series Sensor Probe IL-S065
Base distance: 65 mm
Measuring distance: 55 to 75 mm
Highlight range (at reference distance): approx. 55×1700 μm
Enclosure rating: IP67
Pollution level: 3
Ring...
|
|
KEYENCE/KEYENCE Sensor Head LJ-V7060
KEYENCE Sensor Head LJ-V7060 Mounting Status: Diffuse Reflection
Reference distance: 60 mm
Enclosure Rating: IP67 (IEC60529)*8
Ambient light: Incandescent lamp: 10,000 lux*9 max
Ambient temperature: 0 to +45 °C*10
Relative humidity: 85%RH to ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor OP-88045
NFPA79 standard Ethernet cable L type 10 m
Length: 10 m
Note: Used for the connection between sensors, PCs or Ethernet switches. When using the IV Series as a UL certified product, use an NFPA79-capable Ethernet cable.
This article introduces KEYENCE/KEY...
|
|
KEYENCE/KEYENCE Amplifier Built-in CMOS Laser Sensor LR-Z Series LR-ZB250CN
Square Reflective M8 connector type 250mm
specification
*1 Reference display value related to detection distance. If the set value is tuned, the value will be displaced. Also, when "-99" is exceeded, the display will turn to "-FF".
*2 The FDA's (CDRH) laser classification is based on the IE ...
|
|
KEYENCE/KEYENCE sensor LJ-G015
Enclosure rating: IP67 (IEC60529)
Ambient light: Incandescent/fluorescent: 5,000 lux*5 max
Ambient temperature: 0 to +50 °C
Relative humidity: 35 to 85 % RH (non-condensing)
Seismic resistance: 10 to 55 Hz, double amplitude 1.5 mm, X,Y,Z ...
|
|
KEYENCE/KEYENCE Laser Sensor LR-X Series Amplifier Bracket OP-88542 for Standard Type
KEYENCE Laser Sensor LR-X Series Amplifier Bracket for Standard Type OP-88542
Shape: Amplifier Bracket for Standard Type (M3 Screws × 2 Accessories)
Material: SUS304 etc
Weight: approx. 32 g
This article introduces the KEYENCE/KEYENCE laser sensor ...
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-M51CP
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-M51CN Mini Slim Permeable Type M8 Connector Type 1.2m
specification
This article introduces the KEYENCE/KEYENCE UV-M/F series of photoelectric sensors with built-in subminiature amplifiers.
|
|
KEYENCE/KEYENCE CMOS Laser Displacement Sensor IL-030
Base distance: 30 mm
Measuring distance: 20 to 45 mm
Enclosure rating: IP67
Pollution level: 3
Ambient light: Incandescent lamp: 5,000 lux*5
Ambient temperature: -10 to +50 °C (no condensation, no freezing)
Relative humidity: 35 to 85 % RH ( ...
|
|
KEYENCE/KEYENCE Amplifier Built-in CMOS Laser Sensor LR-Z Series OP-87619
Connector cable M8L word 2m resistant
Type: Connector cable Chemical resistant
End Shape: M8 L-Shaped - Loose Wire
Length: 2 m
Material: Cable: PVC, Nut: SUS316L
Weight: approx. 70 g
This article introduces the KEYENCE/KEYENCE amplifier built-in CM ...
|
|
KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87907
Ethernet cable (M12 4pin-RJ-45) NFPA79 standard standard cable 1 m
Type: Ethernet cable
Length: 1 m
Weight: approx. 100 g
This article introduces the KEYENCE/KEYENCE Multi-Point Laser Sensor OP-87907 product.
|
|
KEYENCE/KEYENCE Sensor Head Spot Type LK-H050
Sensor head Spot Type LK-H050
specification
This article introduces the KEYENCE/KEYENCE sensor head light spot type LK-H050 products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your call, hope our technology and service can ...
|
|
KEYENCE/KEYENCE CMOS Laser Displacement Sensor Controller LK-G5001PV
Built-in controller PNP LK-G5001PV
specification
This article introduces KEYENCE/KEYENCE CMOS laser displacement sensor controller LK-G5001PV products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your call, we hope to ...
|
|
KEYENCE/KEYENCE Ultra-Compact Amplifier Built-in Photoelectric Sensor PR-M/F Series PR-FB30C3PL
KEYENCE/KEYENCE Ultra-Small Amplifier Built-in Photoelectric Sensor PR-M/F Series Flat BGS Reflective M8 Connector Type 30mm PR-FB30C3PL
specification
In this article, we introduce the KEYENCE/KEYENCE SUBMINIATURE amplifier built-in photoelectric sensor PR-M/F Series PR-FB30C3PL ...
|
|
KEYENCE/KEYENCE amplifier built-in TOF laser sensor LR-T series MU-CB2
Power cable for MU-N series
End Shape: Cable Termination: 2 Core Loose Wire, Controller: Connector
Length: 2 m
Material: PVC (Vinyl Chloride)
Remarks: For extended units
Weight: approx. 100 g
This article introduces the KEYENCE/KEYENCE amplifier built-in TOF laser ...
|
|
KEYENCE/KEYENCE Sensor Head LJ-V7200
KEYENCE Sensor Head LJ-V7200 Mounting Status: Diffuse Reflection
Reference distance: 200 mm
Enclosure rating: IP67 (IEC60529)*7
Ambient light: Incandescent lamp: 10,000 lux*8 max
Ambient temperature: 0 to +45 °C*9
Relative humidity: 85%RH to ...
|
|