    Product Introduction
    EATON Contactors & Thermal Overload Relays DILA-22 Current Rating 4A AC15 Contact Current Rating 4 A Range xStart Contact Voltage Rating 415 V AC
Product Description
Product Brief of DILA-22: Series DILA Normal State Configuration 2 NO / 2 NC Number of Auxiliary Contacts 0 End Type Screw Length 45mm Depth 125.2mm Width 68mm.
Eaton Relays:
EATON Overload Relay DILA-22 2 Closed & 2 Disconnect Contacts
Product technical parameters
Contact current rating
4 A
range
xStart
Contact voltage rating
415 V AC
series
DILA
Normal state configuration
2 Normally Open/2 Normally Closed
Number of auxiliary contacts
0
Connector type
screw
length
45mm
depth
125.2mm
width
68mm
Maximum operating temperature
+60°C
Minimum operating temperature
-25°C



  The above is the product introduction of EATON contactor and thermal overload relay DILA-22, this product introduction is: series DILA normal state configuration 2 NO / 2 NC number of auxiliary contacts 0 terminal type screw length 45mm depth 125.2mm width 68mm.


  All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.

More on that
EATON 7A AC Contactor Relay DILM7-10C(220-230V50HZ) EATON 7A AC Contactor Relay DILM7-10C(220-230V50HZ)

DILM7-10C Product Introduction: Same form factor for AC and DC operation simplifies design Contactors of 32A and below can be controlled directly by the PLC, thus reducing the number of intermediate relays With extremely low heat dissipation, the control cabinet can allow for higher mounting densities EATO ...

Eaton Relay Control DILER-40 230V 4 NO Eaton Relay Control DILER-40 230V 4 NO

Product Brief for DILER-40: Surface Mount or DIN Rail Mount Maximum Rated Voltage 500V AC/250V DC Dimensions: H x W X D58 x 45 x 52 mm. Eaton Relays: Product Technical Parameters The above is EATON/Eaton Relay Control Type D ...

EATON Relay Overload ZB32 6-10A Rated Power 6 W EATON Relay Overload ZB32 6-10A Rated Power 6 W

Product Brief for ZB32: Protective Single-Phase Sensitivity for ATEX Motors According to IEC/EN 60947 When the overload relay is not mounted directly on the contactor or when multiple contactors are used, a mounting bracket is required (stock no. 493-0488- ZB32 only). Eaton UPS: Products...

EATON Contactor Relay DILA-40 24V DC 4 Closed Contacts EATON Contactor Relay DILA-40 24V DC 4 Closed Contacts

Product Brief of DILA-40: Contact Rated Current 4 A Range xStart Contact Rated Voltage 400 V ac Series DILA Normal State Configuration 4 NO Number of Auxiliary Contacts 0 Terminal Type Screw Length 68mm Depth 117mm Width 45mm. Eaton Relays: ...

EATON Contactors & Thermal Overload Relays XTOMP40AC1 Contacts are rated at 10 A EATON Contactors & Thermal Overload Relays XTOMP40AC1 Contacts are rated at 10 A

XTOMP40AC1 Product Brief: Eaton's Cutler-Hammer XT Miniature Overload Relays feature non-reverse and reverse miniature contactors, miniature overload relays, and snap-on attachments. XT Series Miniature Overload Relays with Compact Design, Economical and Eco-Friendly Compact Design Phase ...

EATON relay, overload, ZB12, control voltage 500 V AC EATON relay, overload, ZB12, control voltage 500 V AC

Product Brief for ZB12: Suitable for Protection of Atex Motors Single-phase sensitivity according to IEC/EN 60947 When the overload relay is not mounted directly on the contactor or when multiple contactors are used, a mounting bracket is required (stock no. 493-0488- ZB32 only). Eaton UPS: ...

Eaton Contactor Relay DILA-31 110V AC 3 Closed with 1 Open Contact Eaton Contactor Relay DILA-31 110V AC 3 Closed with 1 Open Contact

Product Brief of DILA-31: Contact Rated Current 4 A Range xStart Contact Rated Voltage 415 V ac Series DILA Normal State Configuration 3 NO / 1 NC Number of Auxiliary Contacts 0 Terminal Type Screw Length 45mm Depth 125.2mm Width 68mm. ...

EATON Contactors & Thermal Overload Relays ZB150-125 95A - 125A EATON Contactors & Thermal Overload Relays ZB150-125 95A - 125A

Product Brief of ZB150-125: FLC Motor Rating 95 → 125 A Control Voltage 500 V ac Contact Rated Current 125 A Contact Rated Voltage 1 kV AC Mounting Style Direct Contactor Series ZB Normal State Configuration NO/NC Number of Auxiliary Contacts 2 Rated ...

Eaton Thermal Overload Relay 8TT91SDRS contact current rating 10.4 A Eaton Thermal Overload Relay 8TT91SDRS contact current rating 10.4 A

Product Brief for 8TT91SDRS: Normal State Configuration Normally Open/Normally Closed Number of auxiliary contacts 1 Rated power 5.5 kW Reset method Automatic Maximum operating temperature +60°C Operating temperature range -40 → +60 °C Minimum operating temperature -40°C. Eaton Relays: ...

EATON Thermal Overload Relay 8TT93RS contacts are rated at 13 A EATON Thermal Overload Relay 8TT93RS contacts are rated at 13 A

Product Brief for 8TT93RS: FLC Motor Rating 10 → 13 A Contact Rated Current 13 A Contact Rated Voltage 415 V ac Mounting Style Direct Contactor Series ADS8 Normal State Configuration Normally Open/Normally Closed Number of Auxiliary Contacts 1 Rated Power 5.5 kW Reset Square

Eaton Relay Overload ZB65 10-16A Trip Class 10A Eaton Relay Overload ZB65 10-16A Trip Class 10A

ZB65 Product Introduction: These relays are suitable for use with DILM contactors DILM40 to DILM65 Installed under DILM 40 to DILM65 contactors Provide short circuit protection for electric motors When installing overload relays away from the contactor or when using multiple overload relays

EATON Relay, Overload, DIL EZE-4, 2.4-4A Control Voltage 600 V AC EATON Relay, Overload, DIL EZE-4, 2.4-4A Control Voltage 600 V AC

DIL EZE-4 Product Introduction: Contact Rated Current 4 A Contact Rated Voltage 690 V AC Mounting Style Direct Contactor Series ZE Normal State Configuration NO/NC Number of Auxiliary Contacts 2. Eaton UPS: Product technical parameters The above is the product EATO ...

EATON Relay Overload ZB32 16-24A Control Voltage 500 V AC EATON Relay Overload ZB32 16-24A Control Voltage 500 V AC

Product Brief for ZB32: Suitable for Protection of ATEX Motors Single-phase sensitivity according to IEC/EN 60947 Mounting brackets are required when the overload relay is not mounted directly on the contactor or when multiple contactors are used. Eaton Relays: Product technical parameters The above is the EA...

Eaton relay overload ZB32 control voltage 500 V AC Eaton relay overload ZB32 control voltage 500 V AC

Product Brief for ZB32: Protects the motor from phase errors or overloads Short-circuit protection when connected directly to contacts Suitable for protection of ATEX motors Single-phase sensitivity according to IEC/EN 60947 When the overload relay is not mounted directly on the contactor or when multiple connectors are used...

EATON/Eaton Germany Muller MOELLER relay ZB12-4 EATON/Eaton Germany Muller MOELLER relay ZB12-4

Product introduction of ZB12-4: With phase loss sensing and temperature compensation function * Can be reset manually or automatically * With test button The thermal overload relay ZB can also be used to protect the increased safety motor. EATON Relays : detailed Start Series Thermal Overload Relay ZB ...

EATON Contactors & Thermal Overload Relays DILER-22 110ACV EATON Contactors & Thermal Overload Relays DILER-22 110ACV

Product Brief for DILER-22: AC or DC control coil only 10A rated contacts with protection Surface Mount or DIN Rail Mount Maximum Voltage Rating 500 V AC/250 V DC Dimensions: H x W x D 58 x 45 x 52 mm. Eaton Relays: ...

Eaton Thermal Overload Relay 8TT91SDRS contact current rating 10.4 A Eaton Thermal Overload Relay 8TT91SDRS contact current rating 10.4 A

Product Brief for the 8TT91SDRS: This series of overload relays is suitable for use with MEM Eaton package starters. FLC Motor Rating 6.9 → 10.4 A Contact Current Rating 10.4 A Mounting Style Direct Contactor Series ADS8 Normal ...

EATON Thermal Overload Relays XTOMP40AC1 Contacts rated at 10 A EATON Thermal Overload Relays XTOMP40AC1 Contacts rated at 10 A

XTOMP40AC1 Product Introduction: FLC Motor Rating 12 A Contact Current Rating 10 A Pole Configuration 3P Mounting Style Direct Mount Series XTOM Normal State Configuration Normally Open/Normally Closed Number of Auxiliary Contacts 2. Eaton Relays: Product technical parameters Above...

EATON Contactor Miniature Relay DILER-40-G 4NO 24V DC Operation EATON Contactor Miniature Relay DILER-40-G 4NO 24V DC Operation

Product Brief for DILER-40-G: Surface Mount or DIN Rail Mount Maximum Rated Voltage 500V AC/250V DC Dimensions: H x W x D58 x 45 x 52 mm. Eaton UPS: Product technical parameters The above are EATON/Eaton Contactor Miniature Relays ...

EATON Contactors & Thermal Overload Relays DILA-40 4 Closed Contacts EATON Contactors & Thermal Overload Relays DILA-40 4 Closed Contacts

Product Brief of DILA-40: Normal State Configuration 4 NO Number of Auxiliary Contacts 0 End Type Screw Length 45mm. Eaton Relays: Product technical parameters The above products are EATON Contactors and Thermal Overload Relays DILA-40 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top