EATON Contactors & Thermal Overload Relays DILA-40 4 Closed Contacts
Product Brief of DILA-40: Normal State Configuration 4 NO Number of Auxiliary Contacts 0 End Type Screw Length 45mm.
Eaton Relays:
Product technical parameters
The above products are EATON Contactors and Thermal Overload Relays DILA-40 ...
|
|
EATON Direct Contactor Overload Relay ZB150-50
Product Brief for ZB150-50: FLC Motor Rating 35 → 50 A Control Voltage 500 V ac Contact Current Rating 50 A Contact Voltage Rating 1 kV AC Mounting Style Direct Contactor Series ZB Normal State Configuration Normally Open/Normally Closed.
Eaton Relays:
Give birth...
|
|
EATON relay, overload, ZB12, control voltage 500 V AC
Product Brief for ZB12: Suitable for Protection of Atex Motors Single-phase sensitivity according to IEC/EN 60947 When the overload relay is not mounted directly on the contactor or when multiple contactors are used, a mounting bracket is required (stock no. 493-0488- ZB32 only).
Eaton UPS:
...
|
|
EATON Relay Overload ZB65 40-57A Trip Class 10A
Product Brief of ZB65: FLC Motor Rating 40 → 57 A Control Voltage 500 V AC Contact Rated Current 57 A Contact Rated Voltage 690 V AC Mounting Style Direct Contactor Series ZB65 Normal State Configuration NO/NC Auxiliary Contact ...
|
|
EATON Contactors & Thermal Overload Relays ZB12-6 Contact Rated Current 6 A
Product brief for ZB12-6: Protects the motor from phase errors or overloads, provides short-circuit protection when connected directly to the contacts Suitable for the protection of ATEX motors Single-phase sensitivity according to IEC/EN 60947 When the overload relay is not mounted directly on the contactor or when multiple connectors are used...
|
|
EATON relay, overload, ZB32 control voltage 500 V AC
Product Brief for ZB32: Suitable for the protection of ATEX motors Single-phase sensitivity according to IEC/EN 60947 Mounting brackets are required when the overload relay is not mounted directly on the contactor or when multiple contactors are used.
Eaton Relays:
Product technical parameters
Above...
|
|
Eaton Thermal Overload Relay 8TT89 contact current rating 2.5 A
Product Brief for 8TT89: Number of Contacts 1 Rated Power 1.1 kW Reset Method Automatic Width 105.8mm Depth 96.9mm Length 159.4mm Maximum operating temperature +60°C Operating temperature range -40 → +60 °C Minimum operating temperature -40°C.
Eaton...
|
|
EATON Thermal Overload Relays XTOMP40AC1 Contacts rated at 10 A
XTOMP40AC1 Product Introduction: FLC Motor Rating 12 A Contact Current Rating 10 A Pole Configuration 3P Mounting Style Direct Mount Series XTOM Normal State Configuration Normally Open/Normally Closed Number of Auxiliary Contacts 2.
Eaton Relays:
Product technical parameters
Above...
|
|
EATON Thermal Overload Relay 8TT91RS Contact Current Rating 6 A,
Product Brief for the 8TT91RS: This series of overload relays is suitable for use with MEM Eaton package starters. Rated power 2.2 kW Reset method Automatic Width 105.8mm Depth 96.9mm Length 159.4mm Maximum operating temperature +60°C Operating temperature
|
|
EATON Contactors & Thermal Overload Relays ZB150-125 95A - 125A
Product Brief of ZB150-125: FLC Motor Rating 95 → 125 A Control Voltage 500 V ac Contact Rated Current 125 A Contact Rated Voltage 1 kV AC Mounting Style Direct Contactor Series ZB Normal State Configuration NO/NC Number of Auxiliary Contacts 2 Rated ...
|
|
Eaton Contactor Relay DILA-31 110V AC 3 Closed with 1 Open Contact
Product Brief of DILA-31: Contact Rated Current 4 A Range xStart Contact Rated Voltage 415 V ac Series DILA Normal State Configuration 3 NO / 1 NC Number of Auxiliary Contacts 0 Terminal Type Screw Length 45mm Depth 125.2mm Width 68mm.
...
|
|
EATON 7A AC Contactor Relay DILM7-10C(220-230V50HZ)
DILM7-10C Product Introduction: 32A and below specifications contactors can be directly controlled by PLC, thus reducing the number of intermediate relaysAll DC operated products and AC operated 115A, 150A, 170A products have built-in suppressors, simplifying engineering Eaton & Muller 7A AC Contactor Type ...
|
|
Eaton Relay Control DILER-40 230V 4 NO
Product Brief for DILER-40: Surface Mount or DIN Rail Mount Maximum Rated Voltage 500V AC/250V DC Dimensions: H x W X D58 x 45 x 52 mm.
Eaton Relays:
Product Technical Parameters The above is EATON/Eaton Relay Control Type D ...
|
|
EATON Overload Relay DILER-22 is rated at 3A
Product Brief for DILER-22: Surface Mount or DIN Rail Mount Maximum Voltage Rating 500V AC/250V DC Dimensions: H x W X D58 x 45 x 52 mm.
Eaton UPS:
Product technical parameters
The above is EATON/Eaton Overload Relay Diler ...
|
|
EATON Contactor & Thermal Overload Relay ZB32-6 Contact Current Rating 6 A
Product Brief for ZB32-6: Protects the motor from phase errors or overloads Short-circuit protection when connected directly to contacts Suitable for protection of ATEX motors Single-phase sensitivity according to IEC/EN 60947 When the overload relay is not directly mounted on the contactor or when using multiple...
|
|
EATON/Eaton Germany Muller MOELLER relay ZB12-4
Product introduction of ZB12-4: With phase loss sensing and temperature compensation function * Can be reset manually or automatically * With test button The thermal overload relay ZB can also be used to protect the increased safety motor.
EATON Relays :
detailed
Start Series Thermal Overload Relay ZB ...
|
|
EATON Thermal Overload Relay 8TT94 Contact Rated 18 A
Product introduction of 8TT94: Contact current rating 18 A, 13 → 18 A direct contactor, contact voltage rating 415 V AC ADS8 series 105.8mm auto 1, 9 kW + 60°C NO / NC.
Eaton Relays:
Product technical parameters
The above is EATON/Eaton hot ...
|
|
EATON Relay Overload ZB65 6-10A Trip Rating 10A
ZB65 Product Introduction: These relays are suitable for use with DILM contactors DILM40 to DILM65 Installed under DILM 40 to DILM65 contactors Provide short circuit protection for electric motors When installing overload relays away from the contactor or when using multiple overload relays
|
|
EATON Overload Relay AFDD-40/2/C/003-A is not a trip current
AFDD-40/2/C/003-A Product Introduction: Test and Stop Function With de-indication on the front end Temperature Compensation Suitable for AC or DC applications Suitable for three-phase and single-phase applications.
Eaton Relays:
Product Details:
The above is EATON/Eaton Overdrive ...
|
|
Eaton Thermal Overload Relay 8TT91SDRS contact current rating 10.4 A
Product Brief for 8TT91SDRS: Normal State Configuration Normally Open/Normally Closed Number of auxiliary contacts 1 Rated power 5.5 kW Reset method Automatic Maximum operating temperature +60°C Operating temperature range -40 → +60 °C Minimum operating temperature -40°C.
Eaton Relays:
...
|