project | content |
Order product number | HG-C1030-P |
Model | HG-C1030-P |
Fit the specifications | EMC is compliant with directives and FDA regulations |
Measure the distance to the center | 30mm |
Measuring range | ±5mm |
Repeatability | 10μm |
linearity | ±0.1% F.S. |
Temperature characteristics | 0.03% F.S./℃ |
light source | Red Diode Laser Class 2 (JIS/IEC/GB)/Class II (FDA) (Note) |
Maximum output: 1mW |
Peak wavelength of projection: 655nm |
Note: Comply with FDA rules in accordance with Laser Notice No. 50 of the FDA Regulations. |
Beam diameter | Approx. ø 50 μm |
Note: Measure the magnitude of the center distance. Defined as 1/e2 (about 13.5%) of the central light intensity. If there is a light leak outside the defined area and there is a strong reflection around the detection point that is higher than the detection point itself, the measurement results may be affected. |
Supply voltage | 12~24V DC±10% pulsation P-P10% or less |
Current consumption | 40mA or less (at 24V DC) |
65mA or less (at 12 V DC) |
Note: Specifications will be changed from June 2016 onwards. Products manufactured before May 2016: 40 mA or less (at 24 V DC), 60 mA or less (12 VDC) |
Control the output | PNP open-collector transistors |
・Maximum source current: 50mA |
・Applied voltage: 30V DC or less (control output -+V) |
・Residual voltage: 1.5 V or less (at 50 mA outflow current) |
・Leakage current: 0.1mA or less |
Control Output: Output action | ON when the light is in/ON when the light is not in the light can be switched |
Control Output: Short Circuit Protection | Equipped (auto-recovery) |
Analog Output: Analog voltage output | ・Output range: 0~5V (+5.2V during alarm) |
・Output impedance: 100Ω |
Analog Output: Analog current output | ・Output range: 4~20mA (0mA in case of alarm) |
・Output impedance: 300Ω |
Note: Since June 2016, an analog current output function has been added. |
Reaction time | 1.5ms/5ms/10ms switchable |
External inputs | PNP has no contact input |
・Enter the conditions |
Invalid: 0~+0.6V DC or open circuit |
Valid: +4~+V DC |
・ Input impedance: Approx. 10kΩ |
Defacement | 2 |
Use levels | 2,000m or less |
Environmental resistance: Protective structure | IP67(IEC) |
Environmental resistance: The ambient temperature at which it is used | -10~+45°C (note that condensation and freezing are not allowed), 20~+60°C when storing |
Environmental resistance: Ambient humidity is used | 35~85%RH, when stored: 35~85%RH |
Environmental resistance: The illumination of the use environment | Incandescent lamp: 3,000 lx or less on the light-receiving surface |
Environmental resistance: Vibration resistance | Endurance 10~55Hz (cycle 1 minute) Double amplitude 1.5mm XYZ in all directions for 2 hours |
Environmental resistance: impact resistance | Endurance: 500 m/s2 (approx. 50 G) 3 times in each direction of XYZ |
cable | 0.2mm2 5-core composite cable, 2m long |
Cable extension | Cables of 0.3mm2 or more can be extended up to 10m in total length |
Material | Body shell: die-cast aluminum |
Front cover: Acrylic |
weight | Weight: Approx. 35g (without cable), Approx. 85g (including cable) |