Introduction: E+H/Endershaus Guided Wave Radar Measuring Travel Time Principle Levelflex FMP57
Features:
Reliable measurement even under variable measuring product or process conditions
HistoROM integrates a data storage unit for fast and easy commissioning, repair, and diagnostics
The innovative multi-echo tracking technology brings a high degree of reliability to the measurement results
The hardware and software are developed according to IEC 61508 up to SIL3
Heartbeat technology for efficient and safe plant operations throughout the entire lifecycle
Seamless integration into control or asset management systems, intuitive guided operating concept (on-site or via control system)
Through the world's authoritative SIL and WHG test certification, save your time and economic costs
Product parameters
Measuring principle
Guided wave radar
Features/Applications:
Premium precision equipment with a maximum tensile force of 30kN
Rod probes, cable probes
Built-in data storage unit. Pre-calibrated at the factory, reliably measured: dust is quiet, in high and narrow silos, in containers with built-in devices.
peculiarity
Heartbeat technology,
Bluetooth® debugging,
Operate and maintain the SmartBlue App,
HistoROM、
RFID TAG for easy identification
Power/Communications
Two-wire system (HART, PROFIBUS PA, FOUNDATION Fieldbus)
Quad Limit (HART)
Measurement accuracy
Rod probe: +/- 2 mm (0.08 in)
Cable Probes < = 15 m (49ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49ft):
+/- 10 mm (0.39 in)
Ambient temperature
-40...+80 °C
(-40...+176 °F)
Process temperature
–40...+150 °C
(–40...+302 °F)
Process pressure (absolute)/maximum overpressure limit
Vacuum... 16 bar
(Vacuum...) 232 psi)
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the E+H/Endershaus guided wave radar measurement travel time principle Levelflex FMP54 product, if you are interested in vortex flowmeter, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience
|
More on that
|
E+H/Endershaus temperature transmitter iTEMP® TMT181
Introduction: The E+H/Endershaus temperature transmitter iTEMP® TMT181, with its excellent reliability, accuracy and long-term stability, can be used in critical processes in all industries, transmitting not only RTD and TC conversion signals, but also resistance and ...
|
|
E+H/Endershaus Ultrasonic Sludge Interface Sensor Turbimax CUS71D IP68
Description: E+H/Endershaus Ultrasonic sludge interface sensors Turbimax CUS71D, Turbimax CUS71D continuously monitor the separating and transition layers in clarifiers and sedimentation tanks for safe, cost-effective and efficient sedimentation processes.
Features:
Reliable: Sensors ...
|
|
E+H Proline Promass F 100 Gas error ± 0.35%
Introduction: E+H/Endershaus Mass Flow Meter Proline Promass F 100 is the best tool for system integrators, skid-mounted equipment manufacturers for accurate measurement under changing process conditions, and in combination with the smallest transmitter available.
|
|
E+H/Endershaus sheath TWF16 with a insertion depth of 2.2mm
Introduction: E+H/Endershaus sheath TWF16, a special ceramic sheath is required for process measuring points at extremely high temperatures. The sheath made of special materials protects the sensor from mechanical and chemical damage during use and prolongs its service life. As a result: savings in measurement ...
|
|
E+H/Endershaus iTHERM ModuLine TT151
Introduction: E+H/Endershaus iTHERM ModuLine TT151, TT151 protective sleeves are designed in accordance with DIN 43772, ASME B40.9, NAMUR NE 170 standards and can also be customized according to user requirements.
Features:
TT151 Standard Industrial Protective Sleeve, Composed of Integral Bar ...
|
|
E+H/Endershaus Ultrasonic Level Meter FMU41 4-20 mA HART
Product Introduction: All-in-one measuring transmitter for non-contact level measurement of liquids, slurries and lumps Pros Menu-based on-site operation with four-line plain text display for quick and easy instrument commissioning in 7 languages Field envelope display for easy instrument troubleshooting ...
|
|
E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FMU44
Introduction: E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FMU44, Prosonic FMU44 is suitable for non-contact level measurement of liquids, slurries and solid lumps as well as flow measurement in open channels and measuring weirs. Two- or four-wire integrated transmitters can be used for storage...
|
|
E+H/Endershaus digital dissolved oxygen sensor Oxymax COS22D with a diameter of 12 mm
Introduction: E+H/Endershaus Digital dissolved oxygen sensor Oxymax COS22D, Oxymax COS22D ensures the safety of media, processes and plant equipment from the effects of oxygen. Reliable measurement in the measuring range helps the user to better monitor and control the operating conditions. Low maintenance of the sensor ...
|
|
E+H/Endershaus ultrasonic level sensor FMU43 limit level detection FDU9x
Product Introduction: All-in-one measuring transmitter for non-contact level measurement of liquids, slurries and lumps Pros Menu-based on-site operation with four-line plain text display for quick and easy instrument commissioning in 7 languages Field envelope display for easy instrument troubleshooting ...
|
|
E+H/Endershaus radar measurement Micropilot FMR540
Introduction: E+H/Endershaus Radar Measurement Micropilot FMR540, Micropilot FMR540 NMi and PTB certified for metering transfer and inventory control measurements, meeting the relevant requirements of R85 and API 3.1B standards.
Features:
The accuracy is better than 1mm
...
|
|
E+H Electromagnetic Flow Meter Proline Promag 10L Volume Flow ±0.5 %
Introduction: The E+H/Endershaus electromagnetic flowmeter Proline Promag 10L is a versatile standard sensor for the water and wastewater industry, with a loose flange process connection for flexible installation independent of the installation of the pipe flange. The combination meets the basic application and is able to directly integrate ...
|
|
E+H/Endershaus Capacitive Limit Detection Minicap FTC260
Introduction: E+H/Endershaus Capacitive Limit Detection Minicap FTC260, Minicap FTC260 rod probe is simple and economical for solid bulk material limit level detection, especially for corrosive or large amounts of adhesion formed media. This probe is designed for lightweight, solid, ...
|
|
E+H/Endershaus tuning fork level switch Liquiphant FTL51
Description: E+H/Endershaus Tuning Fork Level Switch Liquiphant FTL51, Liquiphant FTL51 Tuning Fork Limit Detection Switch with extension tube, can be used in explosion hazard areas, has various international approvals, and is suitable for all industries.
Features:
Can be used for functional ...
|
|
E+H/Endershaus ultrasonic sensor Prosonic FDU91 ultrasonic measurement
Description: E+H/Endershaus Ultrasonic Sensor Prosonic FDU91, the FDU91 ultrasonic sensor is suitable for continuous, maintenance-free level measurement of liquids, slurries, sludges, powders and solid lumps, and can also be used for flow measurement in open channels and measuring weirs.
Give birth...
|
|
E+H/Endershaus Modular Thermocouple Thermometer TC10
Introduction: The E+H/Endershaus Modular Thermocouple Thermometer TC10 is a highly modular, rugged thermometer for almost all industry applications. Compatible with all common communication protocols, the head-mounted transmitter is ready-to-use, with enhanced ...
|
|
E+H/Endershaus Electromagnetic Flowmeter Proline Promag H 500
Introduction: The E+H/Endershaus electromagnetic flowmeter Proline Promag H 500 sensor is particularly suitable for hygienic applications and meets the highest demands in the food and beverage and life sciences industries. In combination with the innovative split transmitter, the Promag H 5 ...
|
|
E+H/Endershaus pH/ORP combination electrode Memosens CPS76D is IP68 rated
Description: E+H/Endershaus Digital pH/ORP Combination Sensor Memosens CPS76D, Memosens CPS76D sensor enables simultaneous pH and ORP measurement in harsh and hygienic applications, improving process control and product quality.
Features:
Same...
|
|
E+H/Endershaus Bar Protector TA566 Insertion depth 900 mm
Introduction: E+H/Endershaus Bar Protective Sleeve TA566 Because of the harsh process conditions, the strength of the protective sleeve must be precisely calculated. Dyeing penetration test, ultrasonic test, helium leak test, pressure durability test, and various non-destructive material tests to prove the material and workmanship.
|
|
E+H/Endershaus Radar Level Measurement Micropilot NMR81 Input 4-20mA
Description: E+H/Endershaus Radar Level Measurement Micropilot NMR81, Micropilot NMR81 can be used for metering transfer and inventory control measurements, is NMi and PTB certified and meets the relevant requirements of R85 and API 3.1B standards. NMR81 is particularly suitable for measurements in free space ...
|
|
E+H/Endershaus Bar Protector TA570 inserts to a depth of 5 mm
Introduction: E+H/Endershaus Bar Protective Sleeve TA570, because of the harsh process conditions, the strength of the protective sleeve must be precisely calculated. Dyeing penetration test, ultrasonic test, helium leak test, pressure durability test, and various non-destructive material tests to prove the material and workmanship.
|
|