Description: E+H/Endershaus Radar Level Measurement Micropilot NMR81, Micropilot NMR81 can be used for metering transfer and inventory control measurements, is NMi and PTB certified and meets the relevant requirements of R85 and API 3.1B standards. NMR81 is particularly suitable for measurements in free space with a maximum range of 70 m. The waterdrop antenna with an operating frequency of 80 GHz and a small beam angle of 3° avoids the influence of any interference close to the tank wall.
Features:
Hardware and software design according to IEC 61508 with a maximum safety of SIL3 (in homogeneous redundant systems)
The highest measurement accuracy is ±0.5mm (±0.02"), resulting in the highest reliability
Designed in accordance with international metrology laws such as OIML R85 and API MPMS standards
Local and national approvals, e.g. NMi certification or PTB certification in custody transfer applications
Easy connection to the upper DCS system via an open protocol for easy installation and trouble-free operation
80 GHz technology with a highly concentrated beam angle that is not disturbed by tank walls and other structures
Product parameters
Measuring principle
Radar level gauge
Features/Applications:
Planar Antenna, 80GHz: High Accuracy Tank Measurements Up to 30 m (98 ft)
peculiarity
Metering transfer level measurement
Measure close to the tank wall
Power/Communications
85…264VAC
Measurement accuracy
Up to 0.5 mm
Ambient temperature
Standard:
-40…60°C
(-40…140°F)
Calibration meets regulatory requirements:
-25…55°C
(-13…131°F)
Process temperature
-40…200°C
(-40…392°F)
Process pressure (absolute)/maximum overpressure limit
Vacuum...... 16 bar abs
The main wetted parts
316L、PTFE
Process connections
Flange:
DN50/2"…DN300/12"
Flange, with/without position adjustment tool:
DN100/4"…DN300/12"
UNI Flange:
DN150/6"…DN300/12"
UNI flange with/without position adjustment tool:
DN150/6"…DN300/12"
Maximum measuring distance
70 m (230 ft)
Regulatory Compliance Calibration:
30 m (98 ft)
correspondence
Output:
Fieldbus: Modbus RS485, V1, HART
4… 20mA analogue output (Exi/Exd)
Relay Output (Exd)
Input:
4… 20mA Analog Input (Exi/Exd)
Two-wire, three-wire, four-wire RTD input
Digital inputs (Exd, passive/active)
Certificates and certifications
ATEX、FM、IEC Ex、EAC
Security certifications
Overfill protection WHG
SIL
Design Certification
EN 10204-3.1
NACE MR0175、MR0103
AD2000
Metrological Certifications and Certificates
OIML、NMi、PTB
Options
Redundant fieldbuses
Aluminum-coated housing or 316L housing
Protective cover
Adjustable mounting seals
Apply restrictions
The maximum measuring range is dependent on the tank farm and/or application
Severe condensation or adhesion
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces the E+H/Endershaus radar level measurement Micropilot NMR81 product, if you are interested in E+H/Endershaus radar level measurement, please also contact our staff, we look forward to your call, hope our technology and service can bring you a better experience
|
More on that
|
E+H/Endershaus differential pressure transmitter Deltabar PMD75 -40...85 °C
Description: The E+H/Endershaus differential pressure transmitter Deltabar PMD75 with piezoresistive sensor and welded metal film is used in all industries for the continuous measurement of liquids, vapors and gases. The 3-button operation enables simple and reliable commissioning and operation. Integrated HistoROM data module ...
|
|
E+H/Endershaus Capacitive Limit Detection Solicap FTI77 Safety Certified SIL
Introduction: E+H/Endershaus Capacitive Limit Detection Solicap FTI77, Solicap FTI77 Semi-Insulated Sword/Cable Probe for Limit Detection of Fine and Coarse Solids.
Features:
Ultra-rugged probes designed for demanding process conditions
Open...
|
|
E+H/Endershaus Electromagnetic Flowmeter Proline Promag 55S Medium temperature 0...+60 °C
Introduction: The E+H/Endershaus electromagnetic flowmeter Proline Promag 55S is designed for use with media such as inhomogeneous, coarse and corrosive fluids. With an industry-optimized lining, the sensors are rugged and suitable for the most challenging environments and metering jobs, such as wastewater treatment, ...
|
|
E+H/Endershaus Integrated Conductivity Measurement Smartec CLD18 with IP69 degree of protection
Introduction: E+H/Endershaus The Smartec CLD18 is an economical solution for a wide range of applications in the beverage industry, using small pipes and ring measurements as switches. Integrated sensor and transmitter structure, anti-dry...
|
|
E+H/Endershaus radar measures travel time principle FMR50
Introduction: E+H/Endershaus Radar measures the travel time principle FMR50, and the Micropilot FMR50 is ideal for simple applications such as pools and storage tanks, as well as for utility measurements.
Features:
Reliable, non-contact measurement, unaffected by changes in media and process conditions.
|
|
E+H/Endershaus Mass Flow Meter CNGmass Maximum process pressure 5080 psi
Introduction: E+H/Endershaus mass flow meter CNGmass, the accuracy of the dispenser is as important as the accuracy required to measure any other fuel when it comes to measuring and settling CNG. Therefore, the "brain" of every CNG dispenser is a measurement that measures everything from the dispenser to the tank truck ...
|
|
E+H/Endershaus Memograph M RSG45
Description: The E+H/Endershaus Memograph M RSG45, the Advanced Data Manager is a flexible and powerful process value processing system. Intuitive to operate, the Memograph M can be quickly and easily adapted to the requirements of the individual application. The process measured values are clearly displayed in the display ...
|
|
E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FDU92 FDU92
Introduction: E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FDU92 FDU92, FDU92 ultrasonic sensors are suitable for continuous, non-contact level measurement of liquids, slurries, sludges, powders and solid lumps, maintenance-free, and can also be used for flow measurement in open channels and measuring weirs.
|
|
E+H/Endershaus Mass Flow Meter Dosimass Maximum process pressure PN40
Description: E+H/Endershaus Dosimass mass flow meter for flow measurement during dosing and bottling. Volumetric and mass flow with temperature and density compensation can be directly measured to ensure maximum repeatability. Dosimass is suitable for measurement occasions where space is limited, and it is a system ...
|
|
E+H/Endershaus industrial thermometer iTHERM ModuLine TM111
Description: The E+H/Endershaus industrial thermometer iTHERM ModuLine TM111 is easy to use with RTD or thermocouple sensors. Combined with a modular transmitter that supports all common communication protocols - Bluetooth® technology, the meter can be installed for measurement purposes and has the following features.
|
|
E+H/Endershaus Explosion-proof Pt100 thermometer TR63
Introduction: E+H/Endershaus Explosion-proof Pt100 thermometer TR63, this sturdy thermometer is suitable for harsh working conditions and high safety requirements in chemical, oil, gas, energy and other industries. Robust protective tubes and special materials are sufficient to cope with harsh working environments, ...
|
|
E+H/Endershaus Liquid Tuning Fork Level Limit Switch FTL260-0010
Product Introduction: Liquiphant is a liquid limit switch for storage tanks, tanks with agitators and pipelines. It can be used as a substitute for float switches in situations of accumulation, disturbance, liquid flow and air bubbles.
FTL260-0010
[0 ...
|
|
E+H/Endershaus Sheath TA535 insertion depth 10 mm
Introduction: E+H/Endershaus Sheath TA535, with its hexagonal extension, is suitable for industrial applications with medium and advanced process pressures. It is generally fixed to pipes or tanks that use threaded connections. Due to its special construction, it can carry a 6 mm diameter (0.24 in) probe ...
|
|
E+H/Endershaus temperature transmitter iTEMP TMT142B
Description: The E+H/Endershaus temperature transmitter iTEMP TMT142B with backlit display delivers reliable, precise and long-term stable measurement results in harsh conditions and hazardous areas. Built-in Bluetooth® interface for safe remote operation
Features:
...
|
|
E+H/Endershaus digital pH/ORP combination electrode Memosens CPS96E with a diameter of 12 mm
Introduction: E+H/Endershaus Digital pH/ORP combination sensor Memosens CPS96E, Memosens CPS96E is the specialist for the measurement of fibrous media or media with high suspended solids concentrations (e.g. dispersions, precipitants, emulsions). Open-cell diaphragm design, no risk of contamination, ensure reliable p...
|
|
E+H/Endershaus analogue pH electrode Ceragel CPS71 is IP68 rated
Description: E+H/Endershaus analogue pH sensor Ceragel CPS71, Ceragel CPS71 is an analogue electrode designed for pH measurement in sterile and hygienic applications. Its contamination-resistant gel ensures stable measurements in flowing media or low conductivity media. The electrodes can be ...
|
|
E+H/Endershaus radar measurement Micropilot FMR540
Introduction: E+H/Endershaus Radar Measurement Micropilot FMR540, Micropilot FMR540 NMi and PTB certified for metering transfer and inventory control measurements, meeting the relevant requirements of R85 and API 3.1B standards. The FMR540 with parabolic antenna is particularly suitable for ...
|
|
E+H/Endershaus tuning fork level gauge FTL20-002B cable entry 150oC
Product introduction: FTL20-002B is an all-in-one limit detection switch. Typically used in tank farms, vessels and pipelines, in cleaning and filtration systems and cooling and lubrication tanks, for overfill protection or to prevent pumps from running dry.
Tuning fork level meter FTL20-002B
...
|
|
E+H/Endershaus Ultrasonic Measurement of Travel Time Principle Prosonic FMU40
Introduction: E+H/Endershaus Ultrasonic Measurement Stroke Time Principle Prosonic FMU40, Prosonic FMU40 is suitable for non-contact level measurement of liquids, slurries and solid lumps as well as flow measurement in open channels or measuring weirs.
Features:
Four lines of plain text display, ...
|
|
E+H/Endershaus temperature transmitter iTEMP TMT128 DIN rail
Introduction: The E+H/Endershaus DIN rail temperature transmitter iTEMP TMT128 is designed to convert thermocouple (TC) sensor signals over a fixed measuring range.
Features:
High-precision measurements over the entire ambient temperature range
Sensor disconnection ...
|
|